CTLink segments chest CT findings based on radiology report text
CTLink: A Text-Prompted Segmentation Model for Linking Radiology Report Findings to 3D Chest CT Scans
Computer Vision and Pattern RecognitionArtificial Intelligence
Summary
Radiology reports describe problems inside the body in words but don’t show exactly where those problems are on CT scans. To fix this, the authors developed CTLink, a computer model that reads the report text and highlights the matching areas on 3D chest CT scans. They trained this model on thousands of scans and tested it against other models, finding it more accurate at matching text descriptions with precise scan regions. CTLink even matched or did better than doctors in marking these findings on scans.
What this means in practice
- •For medical imaging software developers: Integrate CTLink to enable automatic mapping of radiology report findings onto 3D chest CT images for improved visualization and review.
- •For radiology departments: Use CTLink to assist radiologists by highlighting text-described abnormalities directly on chest CT scans, aiding diagnosis and communication.
Authors
Mohammed Baharoon, Sung Eun Kim, Mahmoud Hussain Alabbad, Lucas Bijnens, Ali Piracha, Reem Alwasiah, Talal Yahyan, Abdulrahman Alamoudi, Mashael Alshehri, Rayan Alsager, Hannah Hancock, Anna M. Hunkemöller, Peter Youssef, Mona A. Alhammad, Afnan Aljumayan, Brecht Van Berkel, Eric Bijnens, Saud Alhussain, Maarten Steyvers, Rolf Symons, Bryan Eelen, Ayed Alaklubi, Maha Buraykan Alshammari, Amirah Fahad Alshammeri, Tomas Gilvydis, Ibrahim AlTurki, Monerah Almohideb, Ali Alburkani, Shahad Alhomaiani, Fatima Jabali, Abdulrhman Aljouie, Daesung Kim, Junha Im, Michael Moritz, Hassan R. Alomaish, Pranav Rajpurkar
Abstract
Radiology reports describe findings in text only, without visually marking them on the scan, so readers cannot directly see which abnormality each reported finding refers to. We introduce CTLink, a text-prompted 3D segmentation model that segments findings described in a chest CT report. CTLink was trained on 4123 noncontrast chest CT scans with 9547 segmented report findings, including ReXGroundingCTv2, a newly annotated dataset of 1134 scans and 1895 findings with every instance of each finding segmented. On the 200 ReXGroundingCT validation scans, CTLink achieved a hit rate of 0.816, an instance F1 score of 0.456, and a mean Dice score of 0.400, compared with 0.533, 0.175, and 0.234 for VoxTell, a publicly available text-prompted segmentation model (P < .001 for all). On the test set of the MICCAI 2026 ReXGrounding challenge, an ensemble of seven CTLink models achieved the highest hit rate (0.782) and instance F1 score (0.386) of all 48 participating teams. On 50 test scans segmented twice by independent radiologists, CTLink matched or exceeded inter-rater agreement. Diffuse non-focal findings remained the main limitation, partly because their extent is outlined inconsistently even between radiologists. The CTLink model weights are available at https://huggingface.co/rajpurkarlab/CTLink, and the dataset at https://huggingface.co/datasets/rajpurkarlab/ReXGroundingCT.