Geometry-bridge method improves head motion correction in cone-beam ct scans

Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

Computation and LanguageComputer Vision and Pattern Recognition

Summary

Motion of a patient's head during a cone-beam CT scan can blur images and make it hard to see anatomy clearly. The authors present a method that learns how the images change when the head moves and uses these learned changes to correct the motion effects. Their approach connects distorted and clean images through simulated motion steps and estimates the head's position with improved accuracy. Tests on many simulated scans show their method creates clearer images and more precise motion estimates than previous techniques, working in about nine minutes per scan.

What this means in practice

  • For medical imaging technicians: Improve image quality in head cone-beam CT scans by automating correction of patient head motion using learned image updates linked to CT geometry.
  • For radiology device developers: Incorporate a geometry-bridge flow matching technique to enhance algorithms for rigid motion correction in cone-beam CT scanners, leading to better anatomical reconstructions.$Commercial implications: Enables sale of advanced CBCT imaging software that corrects patient motion and improves diagnostic image quality.

Authors

Sungho Yun, Seungryong Cho

Abstract

Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.