Wheeled humanoid robots improve arm accuracy with shared waist calibration
Whole-Body Elasto-Geometrical Calibration of Wheeled Humanoid Robots Using a Shared-Waist Dual-Chain Model
Robotics
Summary
Wheeled humanoid robots move their arms using a single waist joint, but this can cause errors if the waist’s movement isn’t modeled precisely. The authors developed a method to better understand the waist’s behavior and how both arms move together by using measurements from an optical tracker. This new calibration technique makes the robot’s arm positions much more accurate, reducing errors from several centimeters to about a millimeter. Their approach works better than previous methods, especially by accounting for how the waist flexes under different forces.
What this means in practice
- •For robotics engineers: Calibrate both arms of wheeled humanoid robots more accurately by modeling the shared waist joint and arm flexibilities together for better task performance.
- •For robot maintenance teams: Use combined dual-arm calibration data for more reliable robot checks and adjustments, reducing downtime caused by arm positioning errors.
- •For industrial automation integrators: Enhance precision of humanoid robots in factories by applying this calibration method to improve arm accuracy when handling payloads or performing assembly.$Commercial implications: Makes possible higher-precision humanoid robots for industrial tasks, improving productivity and safety in automated production lines.
Authors
Pengxin Zha, Yi Lu, Haojun Ma, Jun Zhu, Minghao Qiu, Xiaoyan Wang, Wei Shan, Maoqing Yao
Abstract
Wheeled humanoid robots carry both arms on one actuated waist, usually without torque sensors, so the accuracy of both end-effectors depends on a single waist model. After a first stage that estimates the tracker and target extrinsics, we identify the waist and both arms in one problem from the target positions on both flanges, measured by an optical tracker. The kinematic model is complete, with waist-base, parallel-axis, and branch parameters; arm compliances are driven by measured torques and waist compliances by gravity torques of the robot's mass model; and Gaussian priors with evidence-maximizing scales stabilize the estimate. Independent and sequential single-chain calibration are restrictions of this problem, and its waist information is the sum of the single-chain Schur complements. On two robots with different waists, each without and with a payload, calibration reduces the mean errors on held-out poses from 11.3-31.1 mm to 0.50-1.11 mm. For every training-set size from 20 poses to all, the method has 17-63% lower mean errors than adaptations of two published whole-body calibration methods, mainly through the waist compliance. Independent calibration yields two waist models; using either for both arms raises the other arm's error to up to 3.21 mm.