Papers for

robot maintenance teams

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

Wheeled humanoid robots improve arm accuracy with shared waist calibration

Whole-Body Elasto-Geometrical Calibration of Wheeled Humanoid Robots Using a Shared-Waist Dual-Chain Model

Abstract: Wheeled humanoid robots carry both arms on one actuated waist, usually without torque sensors, so the accuracy of both end-effectors depends on a single waist model. After a first stage that estimates the tracker and target extrinsics, we identify the waist and both arms in one problem from the target positions on both flanges, measured by an optical tracker. The kinematic model is complete, with waist-base, parallel-axis, and branch parameters; arm compliances are driven by measured torques and waist compliances by gravity torques of the robot's mass model; and Gaussian priors with evidence-maximizing scales stabilize the estimate. Independent and sequential single-chain calibration are restrictions of this problem, and its waist information is the sum of the single-chain Schur complements. On two robots with different waists, each without and with a payload, calibration reduces the mean errors on held-out poses from 11.3-31.1 mm to 0.50-1.11 mm. For every training-set size from 20 poses to all, the method has 17-63% lower mean errors than adaptations of two published whole-body calibration methods, mainly through the waist compliance. Independent calibration yields two waist models; using either for both arms raises the other arm's error to up to 3.21 mm.

Thu 5 NovRobotics
The gist
Wheeled humanoid robots move their arms using a single waist joint, but this can cause errors if the waist’s movement isn’t modeled precisely. The authors developed a method to better understand the waist’s behavior and how both arms move together by using measurements from an optical tracker. This new calibration technique makes the robot’s arm positions much more accurate, reducing errors from several centimeters to about a millimeter. Their approach works better than previous methods, especially by accounting for how the waist flexes under different forces.
Open → 2611.07560v1

Severity-gated control improves robot walking with damaged legs

SG-CPG: Severity-Gated Central Pattern Generators for Adaptive Quadruped Locomotion under Continuous Actuator Degradation

Abstract: An animal with a weakened limb does not necessarily switch its gait, instead it unloads the affected limb, re-coordinates the remaining limbs, and scales its response with injury severity. This graded adaptation allows locomotion to persist despite partial loss of limb strength, rather than requiring a discrete transition between healthy and failed. Inspired by this behavior, we propose SG-CPG, a central pattern generator (CPG) for quadruped locomotion under continuous actuator degradation. SG-CPG preserves a frozen healthy CPG policy and introduces two severity-driven gates: a residual gate that re-coordinates all four legs and an amplitude gate that progressively shortens the weakened leg's stride as degradation increases. We emulate progressive degradation through two mechanisms: lowering the joint torque ceiling (ceiling mechanism) and scaling its low-level controller gains (gain mechanism), representing distinct forms of actuator weakening. Our simulations on a Unitree Go2 show that SG-CPG maintains a trot gait with 100% survival across an omnidirectional command schedule under 95% joint strength loss while tracking commands within 8%. Under a lowered torque ceiling, removing either severity path, the residual's severity observation or the amplitude gate, raises clipping at the weakened joint from 4.4% to 13.6% and 26.3% of steps at an 80% loss. On a real Go2, SG-CPG survives 28 of 29 forward and turning trials with up to 93% calf torque degradation. These results show that severity-gated adaptation can extend a healthy locomotion policy to progressive actuator degradation without treating the fault as a discrete failure.

Tue 22 SeptRobotics
The gist
Robots with damaged or weakened legs usually struggle to walk and may stop moving or change how they move abruptly. The authors designed a new control system inspired by how animals adjust their walking smoothly when hurt. Their method gradually adjusts each leg’s stride and coordination based on how weak that leg is, allowing the robot to keep walking steadily. Tests on a robot with severely weakened joints showed it could still follow movement commands most of the time without failing.
Open → 2609.25687v1