Microwave signals recovered from magnitude-only data on torso models
When Magnitude Suffices: Reconstructing Time-Domain-Gated Microwave Signals Without Phase on a Thoracic Phantom
Machine Learning
Summary
Measuring microwave signals usually requires capturing both size and direction (phase), which needs expensive tools. The authors show that for a certain setup, just measuring the size of the signals is enough to reconstruct important details, using a neural network. This works well on a body-shaped model with different simulated lung conditions. Their approach allows simpler, cheaper devices to capture useful measurements without detailed phase information.
What this means in practice
- •For medical imaging device developers: Build microwave imaging devices that use simpler, magnitude-only measurements to reconstruct tissue states without phase data after installation.
- •For wireless system engineers: Design microwave diagnostic tools that reconstruct reflection signals from only magnitude data, reducing cost and complexity in calibrated scenarios.
Authors
Maciej Cichoń, Patrycja Gołaś, Maksymilian Bartosik, Angelika Walczak, Agata Bielecka-Dąbrowa, Maciej Ślot
Abstract
Time-domain gating separates the arrivals that form a microwave S-parameter measurement. It requires the measurement of complex values, so this application almost always uses a vector network analyzer (VNA). We show that, on one calibrated measurement configuration, the gated magnitude the VNA would give can be reconstructed from a magnitude-only sweep of a spectrum analyzer with a tracking generator (SA). We select the gate center for separability of the measured states, correct each instrument once by a per-bin subtraction of a reference state, and train a fully connected network on sweeps from both instruments. The test object is a torso phantom with lung-shaped compartments whose filling takes eleven dielectric states, each held out in turn. On $S_{11}$ the reconstruction from SA input reaches a shape error of 0.08 dB$^2$ with a state ordering of 0.81. This matches the reconstruction from VNA input. On $S_{21}$ it reaches 0.82 dB$^2$ and keeps the ordered groups of the states. An explicit phase prediction performs much worse, because gating needs the phase to about 0.2 rad RMS. Across eleven measurement configurations the dependence of phase on magnitude is strong for reflection and weak for transmission. This explains the difference between $S_{11}$ and $S_{21}$. Where the magnitude carries enough of the phase, a scalar instrument gives the gated response without any phase measurement after installation. On the open UM-BMID breast data set, with whole phantoms held out, the shape error of the network is 30 percent lower than that of a per-bin linear map.