Papers for
medical imaging device developers
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Calochill speeds up complex particle shower simulations by 600 times
Just CaloCHILL: fast hadronic shower generation in a learned latent space
Abstract: Calorimeter showers are the most expensive part of detector simulation, and highly granular calorimeters, in which a single hadronic shower leaves thousands of energy deposits, make them more expensive still. We present CaloCHILL (Calorimeter Hits In Learned Latents), a generative model that does not produce these deposits one by one: instead it generates a compact summary of the shower in a learned latent space and expands it to full resolution only at the end. The complete shower, including the arrival time of every hit, is built in three stages: a flow-matching model first sets the number of hits and the earliest hit time in each calorimeter layer, a mean-flow model then generates the latent summary, and the decompressor of a variational autoencoder turns it into the full point cloud, giving every hit its position, energy and time. Sparse attention along the shower axis keeps this compression affordable for showers with thousands of hits. On positive-pion showers in the calorimeter of the International Large Detector, a proposed detector for the FCC-ee, CaloCHILL reproduces the main shower observables, including their time structure. This new model is 600 times faster than its predecessor, while improving on all accuracy metrics considered.
BrainGFM improves brain image tasks with generative AI model
A generative foundation model for computational brain imaging
Abstract: Computational brain imaging is constrained by a mismatch between increasingly diverse tasks and scarce, heterogeneous clinical data. Although existing brain foundation models transfer pretrained representations, their knowledge remains entangled within model-specific features and fixed architectures. This paper proposes BrainGFM, a generative foundation model that extends knowledge transfer beyond representation reuse through a reusable and reconfigurable brain-imaging prior. By pretraining on a corpus of about 1.3 million MRI and CT slices, BrainGFM supported task-aligned data synthesis for low-data predictive learning and task-adapted post-training for image reconstruction. Across 48 downstream tasks, BrainGFM improved segmentation and classification under limited supervision and achieved high-fidelity image enhancement across heterogeneous imaging conditions. Multicenter clinical validation involving 4,796 stroke patients across two internal and four external centers demonstrated its applicability to three clinically relevant tasks around stroke cohorts. Blinded reader assessments showed that BrainGFM-generated FLAIR images approached acquired FLAIR in overall diagnostic quality. In a human-AI collaboration study, BrainGFM assistance yielded a 14% relative improvement in mean radiologist stroke-subtyping accuracy. These findings support generative priors as a reusable foundation for heterogeneous computational brain-imaging applications.
SparseTokenGS improves fast low-dose 3D X-ray image reconstruction quality
SparseTokenGS: Gaussian-based Sparse-View CBCT Reconstruction via Reusable Token Pool
Abstract: Sparse-view cone-beam computed tomography is widely used for fast, low-dose volumetric imaging and lesion localization in dentistry and image-guided interventions, but it introduces severe artifacts. Feed-forward Gaussian methods transfer the reconstruction cost to training and decode each coordinate from projection-aligned features and neighboring anchors. However, information from the whole scan is written only when the field is constructed and cannot be retrieved during coordinate decoding, leaving the volume inconsistent within the scan. This is a common limitation of such methods: once the field is fixed, decoding uses only local features and reconstruction quality drops substantially. We propose SparseTokenGS, a Gaussian-based method for sparse-view cone-beam computed tomography reconstruction via a reusable token pool. Anchor Token Fusion and Point-Token Attention query this shared pool at the anchors and at the query coordinates, respectively. The local Gaussian prior is retained, and the volume is reconstructed in one forward pass, without per-scan optimization or a projection-domain loss. On three public chest and dental datasets, SparseTokenGS achieves the highest reconstruction performance among the compared methods. On clinical dental scans, reconstruction from only six projections reaches 29.51 decibels in peak signal-to-noise ratio and a structural similarity of 0.842 against the full-view reference, and off-the-shelf tooth-and-pulp segmentation keeps these structures separable for root-canal localization. Experiments on volcanic rock and chicken show performance after same-object adaptation. A reusable token pool gives feed-forward reconstruction a mechanism that keeps scan-wide context available through decoding and can benefit future rapid clinical lesion localization and analysis. The code is available at: https://github.com/FrankDengAI/SparseTokenGS.
Microwave signals recovered from magnitude-only data on torso models
When Magnitude Suffices: Reconstructing Time-Domain-Gated Microwave Signals Without Phase on a Thoracic Phantom
Abstract: Time-domain gating separates the arrivals that form a microwave S-parameter measurement. It requires the measurement of complex values, so this application almost always uses a vector network analyzer (VNA). We show that, on one calibrated measurement configuration, the gated magnitude the VNA would give can be reconstructed from a magnitude-only sweep of a spectrum analyzer with a tracking generator (SA). We select the gate center for separability of the measured states, correct each instrument once by a per-bin subtraction of a reference state, and train a fully connected network on sweeps from both instruments. The test object is a torso phantom with lung-shaped compartments whose filling takes eleven dielectric states, each held out in turn. On $S_{11}$ the reconstruction from SA input reaches a shape error of 0.08 dB$^2$ with a state ordering of 0.81. This matches the reconstruction from VNA input. On $S_{21}$ it reaches 0.82 dB$^2$ and keeps the ordered groups of the states. An explicit phase prediction performs much worse, because gating needs the phase to about 0.2 rad RMS. Across eleven measurement configurations the dependence of phase on magnitude is strong for reflection and weak for transmission. This explains the difference between $S_{11}$ and $S_{21}$. Where the magnitude carries enough of the phase, a scalar instrument gives the gated response without any phase measurement after installation. On the open UM-BMID breast data set, with whole phantoms held out, the shape error of the network is 30 percent lower than that of a per-bin linear map.
Cardiac MRI scanner system generates instant detailed heart reports
ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation
Abstract: Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation.
Multi-stage AI reconstructs 3D coronary arteries from limited X-rays
Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.