Joint Effects of GPU Server Topology, Parallelism, and Congestion Control on MoE Inference: A Controlled Simulation Study

Distributed, Parallel, and Cluster Computing

Summary

Big AI models called mixture-of-experts can be spread across many graphics processors (GPUs) to work faster. The authors studied how the way these GPUs are connected inside servers and across networks affects the speed of running these AI models. They found that communication time between GPUs makes up most of the waiting time. Different setups of GPU groups and network controls can speed up or slow down the AI work by several times. The study used detailed simulations to compare many hardware and software combinations.

What this means in practice

Authors

Kaikai Yuan, Rui Xi, Yu Liu

Abstract

Mixture-of-experts (MoE) models expand capacity via sparse activation, but inference across GPUs introduces tensor-parallel (TP) collectives and expert-parallel (EP) dispatch and combine operations. Completion time depends not just on communication volume but on how logical groups map onto intra-server interconnects, GPU--NIC connections, and the inter-node network. Using ASTRA-sim with the NS-3 discrete-event backend, we build a controlled matrix of 32 GPU ranks with data and pipeline parallelism fixed at one. Workloads are fixed-length 4096-token prefill-like synthetic Chakra traces from four MoE configurations. Experiments cover six server topologies, four TP/EP partitions, two TP collective algorithms, and four network/congestion-control modes, yielding 768 deterministic simulations. In the 144-configuration feedback-enabled subset per model, exposed communication accounts for 89.9%--95.8% of mean completion time. TP16EP2 requires 3.68--4.35x the mean completion time of TP2EP16. With fixed rank mapping, ASTRA-sim Double Binary Tree (DBT) incurs 28.3%--83.2% more time than Ring. InfiniBand-like High Precision Congestion Control (HPCC) is ~0.9% lower than HPCC over RDMA over Converged Ethernet (RoCE), whereas RoCE with Data Center Quantized Congestion Notification (DCQCN) is 23.8%--35.7% slower than RoCE HPCC. Topology effects are conditional: Topology~6 leads at low TP degrees but loses its advantage at high TP degrees, and additional GPUs or NICs help only when rank mapping balances traffic across injection paths. Under uniform 32-way sharding, the largest checkpoint-weight shard is ~48.75 GB per rank, so all configurations meet a 64 GB per-accelerator weight-residency criterion. Within the evaluated workload and simulator semantics, server topology, parallelism, collective implementation, and congestion control jointly determine exposed communication and completion time.