Using longer wavelengths improves protein crystal detection accuracy
Protein Crystallization Segmentation and Classification Using Subordinate Color Channel in Fluorescence Microscopy Images
Computer Vision and Pattern RecognitionArtificial IntelligenceMachine Learning
Summary
Detecting protein crystals in fluorescent images is important but tricky because the dye's bright spots don’t always match crystal areas. The authors found that looking at color light with longer wavelengths than usual helps find crystals more accurately. Their method reduces mistakes and works well on different protein types, showing better results than traditional color analysis.
What this means in practice
- •For laboratory automation teams: Improve automated protein crystal detection accuracy in fluorescence image analysis pipelines by using subordinate color channels to reduce misclassification.
- •For biotech imaging developers: Develop enhanced fluorescence microscopy software tools that use longer wavelength color intensity for better protein crystal segmentation.
Authors
Truong X. Tran, Marc L. Pusey, Ramazan S. Aygun
Abstract
The accuracy of detecting protein crystals for fluorescence microscopy images is very critical for high throughput and automated systems. Although the trace fluorescent labeling method could highlight protein crystals, reflection and emission from the fluorescence dye is not always due to crystal regions. Therefore, the analysis of the peak wavelength in the emission spectra of a fluorophore may not always yield effective results. In this paper, we show that using the subordinate color intensity corresponding to longer wavelengths than the peak wavelength of the emission spectra could improve the accuracy of protein crystal detection. Hence, we have built a segmentation method based on the percentile intensity of the subordinate color for trace fluorescently labeled (TFL'd) protein crystallization trial images. Compared to using the dominant color channel, our segmentation method on subordinate color channel was able to reduce the misclassification rate of likely-leads or crystals as non-crystals by the percentage of from 9.71% to 2.02% depending on the classifier. Similarly, the accuracy of classifiers were increased by the percentage of from 1.77% to 5.53%. Our method reached around 94% accuracy while keeping misclassification of likely-leads and crystals as non-crystals below 1%. Moreover, to evaluate the generalizability of our method, we have conducted new wet lab experiments on two proteins, Concanavalin A (Con A) and Ab inorganic pyrophosphate (AbIPPase), and the misclassification rate was below 1%. Our experiments show that using the subordinate channel may be more helpful for TFL'd protein trial image classification.