Lightweight model improves incidental abdominal abnormality detection in chest ct scans
FD-AA: A Lightweight Focal-Diffuse And Attenuation-Aware Head for Incidental Abdominal Abnormality Detection in Chest CT
Computer Vision and Pattern Recognition
Summary
Chest CT scans often show parts of the upper abdomen, where there can be unexpected health issues. Detecting these issues is tricky because different organs have varied sizes and tissue properties. The authors created FD-AA, a model that smartly looks at each organ’s details and combines those tiny spots and broader patterns to spot problems better. They tested FD-AA on multiple datasets and found it works better than some earlier methods, even when using different underlying image encoders.
What this means in practice
- •For medical imaging teams: Improve detection software for incidental abnormalities in abdominal organs seen in routine chest CT scans by integrating focal and diffuse pattern analysis.
- •For radiology device developers: Incorporate FD-AA’s attenuation-aware classification head into CT scan image analysis tools to boost accuracy of abnormality identification across different organs.$Commercial implications: Enables better-integrated CT imaging software for healthcare providers to detect incidental findings, appealing to medical device companies and hospitals.
Authors
Haoyan Ding, Kritika Iyer, Halid Yerebakan, Zhenyu Bu, Chushu Shen, Peiyu Duan, Xinyuan Zheng, Sepehr Farhand, Xueqi Guo, Chaowei Wu, Yoshihisa Shinagawa, Gerardo Hermosillo Valadez
Abstract
Routine chest CT captures upper-abdominal structures that may contain clinically relevant incidental abnormalities. Detecting these findings requires feature extraction from organs with different spatial extents and attenuation patterns. We propose FD-AA, a lightweight organ-aware classification head adaptable for frozen 3-D CT encoders. Within each organ, an attenuation-aware module preserves sparse focal evidence, while masked generalized-mean pooling captures diffuse anomaly patterns. In seven abdominal organs, FD-AA with Pillar-0 achieved state-of-the-art (SOTA) performance in both the CT-RATE test set (AUC = 0.798) and the external RAD-ChestCT dataset (AUC = 0.713). More specifically, FD-AA improved macro AUC/AP from 0.763/0.346 to 0.798/0.405 over direct classification using frozen Pillar-0 only (p = 0.034/0.016). Such performance gain generalizes across multiple frozen encoders (AUC improvement on MedicalNet +9.8%, CT-CLIP +14.7%, ResNet +3.7%), demonstrating the effectiveness of FD-AA across different feature representations. These results support the effectiveness of integrating focal-diffuse aggregation with explicit HU evidence for incidental abdominal abnormality detection.