Papers for
ultrasound device manufacturers
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Positive-free synthetic fetal heart defect images improve diagnosis accuracy
Pos4CHD: A Positive-Free Mask-Guided Counterfactual Synthesis Framework for Fetal Congenital Heart Defect Analysis
Abstract: The scarcity of positive cases remains a major bottleneck in developing automated diagnostic systems for fetal Congenital Heart Defects~(CHDs), particularly for rare subtypes. Although normal cases are accessible with effort, positive cases are hard to collect due to low incidence rates and privacy concerns, causing severe class imbalance or absence of positive training samples. Existing works resort to synthesizing positives with conditional generative models, but they are task-specific and require positive training samples, hindering application for fetal CHDs. To this end, we propose a positive-free mask-guided counterfactual generation framework for fetal echocardiography, namely Pos4CHD, which enables realistic, high-quality synthesis of pseudo-positive samples from semantic masks, with only normal samples at hand. Technically, we first develop FE-Gen, a mask-guided generative model tailored for fetal heart ultrasound synthesis that mitigates histogram drift and enhances image-mask spatial alignment. Building on FE-Gen, Pos4CHD employs a mask-to-image generation paradigm for CHD synthesis. It first manipulates semantic masks to simulate fetal-heart structural anomalies and then renders anatomically consistent images. Extensive experiments on in-house datasets, together with expert evaluations, demonstrate the visual fidelity~($-12.97$ FID) and anatomical consistency~($+3.96\%$ DSC) of synthesized images. Further validations across diverse real-world CHD diagnosis tasks exhibit promising results and consistent increments, including zero-shot classification~(achieving $93.25\%$ ACC on EbA and $72.92\%$ ACC on TAPVC), lesion detection~($+6.95\%$ mAP50 on VSD), and anatomy segmentation~($+10.49\%$ DSC on fetal heart) compared with baselines. Codes and models are publicly available on \href{https://github.com/DREAMXFAR/Pos4CHD}{GitHub}.
Compression reduces reliability of ultrasound tissue measurements
Compression Hurts, Pooling Helps: Information Loss in Rayleigh-Scale Estimation from B-Mode Ultrasound
Abstract: Clinical B-mode images are widely available as potential data sources for quantitative ultrasound (QUS) analysis for tissue characterization. However, standard clinical ultrasound devices apply unknown log-compression to RF envelope data before display and storage. Previous work has demonstrated estimation of the underlying RF envelope statistics in the presence of an unknown compression law. Using Fisher information analysis, we show that finite-offset log compression causes severe information loss when estimating the Rayleigh scale $σ$, which controls diffuse speckle. For a single image window, unknown compression raises the minimum achievable variance for unbiased estimation of $σ$ by a compression-independent factor of approximately $\FisherMinInflation$. When $M$ equal-sized windows share the same unknown compression settings, the excess variance decays as $1/M$; even in the most favorable regime, reducing the variance inflation factor below $1.1$ requires $\FisherBestCaseWindows$ windows. Our analysis treats the contrast parameter $a$ as unknown and the boundary offset $b$ as known; estimating $b$ experimentally shows even larger variance. We validate this theory using synthetic estimation experiments and demonstrate RF-scale recovery on real RF-envelope windows from the OASBUD dataset. Together, these results clarify the limitations of using routine B-mode images for QUS.