Untrained cnn speeds up photoacoustic tomography with robust joint reconstruction

Untrained CNN and coefficient-space regularization for joint reconstruction in photoacoustic tomography

Abstract: The joint reconstruction of the initial pressure and spatially varying sound speed in photoacoustic tomography from boundary measurements is considered. A regularized data-driven framework is proposed in which the unknown fields are represented in finite-dimensional wavelet spaces and fixed nonlinear features generated by an untrained convolutional neural network (CNN) are used to reconstruct the initial-pressure coefficients through Tikhonov-regularized least squares. A learned coefficient-space prior is subsequently used to infer the squared sound-speed coefficients. Numerical experiments demonstrate accurate reconstruction on held-out data and strong generalization to previously unseen phantom geometries. The frozen reconstruction map also remains stable under measurement noise not represented during training, with only minor changes in reconstruction accuracy for noise levels up to $10\%$. In comparison with the supervised trained-CNN approach considered in this work, the untrained representation yields substantially smaller reconstruction errors while requiring approximately one-sixth of the computational time. These results demonstrate that fixed random convolutional features combined with regularized coefficient-space learning provide an efficient and robust approach to joint reconstruction in photoacoustic tomography.

Fri 16 OctMachine Learning
The gist
Photoacoustic tomography is an imaging method that uses sound waves to see inside objects, but it's tricky to figure out both the starting pressure and how fast sound travels inside the object. The authors propose a method that combines math-based techniques with features from an untrained neural network (a computer model that starts with random settings) to reconstruct these details reliably. Their approach works well even with noisy data and unseen shapes, and it’s faster and more accurate than methods using trained neural networks. This could help improve imaging quality without needing lots of training data.
Open → 2610.23315v1

Photoacoustic imaging improves initial condition recovery with ai optimization

Initial condition recovery in nonlinear damped viscous photoacoustic tomography using a convolutional neural network-guided gradient-free optimization framework

Abstract: Photoacoustic tomography (PAT) is a hybrid imaging modality that combines high optical contrast with high ultrasonic resolution for biomedical imaging applications. In this work, we investigate the inverse problem of recovering the initial pressure distribution from boundary measurements in the presence of nonlinear acoustic propagation and viscous attenuation effects. To model these phenomena more accurately, we consider a nonlinear damped viscoelastic wave equation incorporating spatially varying sound speed, temporal attenuation, and nonlinear propagation mechanisms. We first establish the well-posedness of the corresponding forward problem using a Galerkin approximation combined with energy estimates and a fixed-point argument. For the inverse problem, we derive existence, uniqueness, and local uniqueness results under suitable assumptions through a harmonic extension reduction, spectral Laplace transform techniques, and observability estimates. To numerically reconstruct the initial pressure field, we develop a hybrid reconstruction framework that combines a convolutional neural network (CNN) with a gradient-free optimization strategy based on the sequential quadratic Hamiltonian (SQH) method derived from Pontryagin's maximum principle. The CNN is used to generate an informative initial guess, while the SQH framework enforces the governing PDE dynamics during the reconstruction process. Numerical experiments demonstrate that the proposed hybrid strategy significantly improves reconstruction quality, contrast, and robustness compared to standalone time-reversal and CNN-based approaches.

Thu 1 OctMachine Learning
The gist
Photoacoustic tomography is a medical imaging technique that captures images by detecting sound waves produced by light absorption in tissues. The researchers studied how to better reconstruct the original pressure distribution inside the body from these sound waves, even when the sound behaves in complex nonlinear and damped ways. They combined a special type of neural network with a gradient-free optimization method to guide the reconstruction process, making it more accurate and robust. Their approach worked better than previous methods that used only neural networks or traditional techniques on their own.
Open → 2610.01015v1

Realistic 3D fetal brain ultrasound images synthesized from anatomy maps

AWR-Net: Decoupling Anatomy and Appearance for 3D Fetal Brain Ultrasound Synthesis

Abstract: Three-dimensional fetal brain ultrasound offers non-ionizing, cost-effective imaging with rich spatial information for comprehensive anatomical assessment, yet its development remains limited by scarce data and annotations. In contrast, fetal brain magnetic resonance imaging has advanced further, supported by larger datasets and mature analysis methods. To leverage these resources, anatomical label maps provide a promising modality-invariant bridge for transferring knowledge from fetal brain magnetic resonance imaging to ultrasound. However, generating ultrasound images from label maps remains challenging because anatomy is tightly entangled with ultrasound appearance. To address this challenge, we separate anatomical correspondence learning from ultrasound appearance adaptation at both the data and model levels. Specifically, we propose the anatomy wavelet residual network, a two-stage framework combining wavelet diffusion and residual refinement. The first stage learns to generate volumes from label maps using atlas pairs in the wavelet domain, while the second stage learns bounded residual corrections from real clinical ultrasound in the image domain. This separation enables realistic synthesis with consistent preservation of normal and abnormal anatomy. Experiments on real fetal brain ultrasound show that our method outperforms representative synthesis methods, with normalized cross correlation of 0.518 versus 0.482 and Fréchet Inception Distance of 8.905 versus 13.319 for the strongest baseline. Beyond synthesis quality, volumes generated from fetal brain magnetic resonance imaging label maps also improve downstream segmentation, particularly for severe abnormal cases. Overall, these results highlight the potential of the proposed framework to leverage rich fetal brain magnetic resonance imaging resources for advancing three-dimensional ultrasound analysis.

Fri 18 SeptComputer Vision and Pattern Recognition
The gist
Getting good 3D ultrasound pictures of a baby's brain before birth is hard because there isn’t enough data. Magnetic resonance imaging (MRI) has more data but looks very different from ultrasound. The authors created a two-step method that first makes a rough ultrasound image from a brain anatomy map, then improves it using real ultrasound details. This approach makes clearer and more accurate ultrasound images from MRI data, helping doctors better understand fetal brain anatomy and abnormalities.
Open → 2609.22635v1

Deep learning fixes heart motion tracking errors in ultrasound imaging

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Abstract: Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

Wed 9 SeptArtificial IntelligenceComputer Vision and Pattern Recognition
The gist
Tracking how the heart muscle moves in ultrasound videos helps doctors understand heart health, but these tracking methods can sometimes drift and give wrong results. The authors show a way to reduce this drifting by making the system remember information over a whole heart cycle and teaching it to respect realistic heart motion. This approach makes measurements of heart muscle strain more reliable and stable when repeated. It could help doctors get better data from heart ultrasounds without extra manual corrections.