Papers for
surgical robotics engineers
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Multimodal model predicts operator retreat in robotic flexible endoscopy
Multimodal Progress-Residual Fusion for Anticipating Navigation Retreat in Robotic Flexible Endoscopy
Abstract: Flexible robotic endoscopes provide access through tortuous anatomy, where friction, deformation, and wall interaction separate commanded insertion from useful distal progress. Operators interpret this mismatch and retreat to recover a navigable configuration. Recognizing the approach to that decision requires relating motor intent to distal response and the local visual scene. We introduce Multimodal Progress-Residual Fusion (MPRF), a causal model that anticipates operator retreat from commands, electromagnetic (EM) tracking, and endoscopic video. A nominal-progress model predicts the response expected in normal or successful navigation; a temporal predictor combines its EM residual with all three observed modalities. In a 150-episode colon-phantom collection, MPRF achieves 0.580 +/- 0.007 AUPRC across three seeds, compared with 0.511 for the strongest reduced-modality control. Complete multimodal histories provide the principal ranking advantage, while the residual adds an explicit intent-response representation with a small, uncertain increment over raw fusion. Analysis of frozen alarms relates warning timing to the behavioral label and explains the increase in event recall under a longer matching window. These results establish a basis for behavioral assistance during operator-controlled navigation.
Robotic endoscopy uses language to find hidden targets reliably
EndoVLA-OOV: Language-Conditioned Out-of-View Target Acquisition in Robotic Endoscopy
Abstract: The scan-then-revisit workflow of upper gastrointestinal endoscopy requires bringing a previously observed suspicious region back into view for closer inspection. Acquiring such targets requires translating anatomical and appearance descriptions into camera motions from partial observations of a confined, deformable environment. We present EndoVLA-OOV, a language-conditioned vision-language-action policy for out-of-view target acquisition in robotic endoscopy. The policy adapts a pretrained backbone to continuous two-degree-of-freedom distal bending commands and combines initial, intermediate, and current images to guide search. To support policy learning, we provide an open-source VLA dataset containing 1,050 episodes across six tasks and approximately 262k observation-action pairs. Physical evaluation spans wet-lens and low-light conditions, two unseen stomach phantoms, and cross-embodiment transfer to an unseen ex-vivo environment. In the cross-embodiment evaluation, the full-data policy achieves 93.3% target acquisition success (28/30). In a controlled training-data comparison, expanding the corpus from 312 to 1,050 episodes increases acquisition success from 40.0% to 90.0% under the same model, training, and test configuration. Instruction and observation interventions further support the use of language and temporal context in the evaluated acquisition tasks. These results support language-guided endoscopic revisitation across the evaluated environments and robot embodiments and demonstrate the benefit of expanded task-specific demonstrations.
Soft-growing robot paths planned safely inside spinal fluid space
Image-Based Path-Planning for Navigation of Soft-Growing Robots in the Spinal Sub-Arachnoid Space
Abstract: Recently, soft robotic procedures are being developed aiming at achieving targeted minimally invasive operations or drug administration in specific locations in the human body. Accordingly, specialized path-planning algorithms need to be investigated for the estimation of efficient paths that would protect the delicate tissue structures and simultaneously satisfy a set of requirements for the efficient navigation of the robot. In this context, we propose an image-based 3D pathplanning algorithm, which is an extension of the A* algorithm, for the navigation of a soft-growing robot inside the spinal subarachnoid space (SSS). The proposed algorithm is capable of estimating a safe pathway towards the goal location, while ensuring the establishment of anchor points that facilitate the efficient steering of the soft robot. The algorithm is evaluated using a highly detailed model of the SSS with respect to its capacity to satisfy the robot movement requirements and path efficiency.
Probabilistic method improves soft tissue cutting in surgery
ProCut: Probabilistic Cutting Topology for Autonomous Electrosurgical Tissue Dissection
Abstract: Accurately modeling and tracking the deformation of soft tissue is critical for a wide range of interventional and surgical procedures. However, current methods struggle in scenarios involving topological changes, such as cutting and dissection, due to the inherent non-linearity and discontinuity introduced by explicit changes in connectivity. In this work, we present a novel, fully differentiable framework that enables robust estimation and modeling of topological changes during deformable tracking. Our method introduces a continuous, sigmoid-based formulation to smooth the otherwise discrete event of tissue cutting, making it amenable to gradient-based optimization within a differentiable Position-Based Dynamics (PBD) simulation. To account for uncertainty and improve robustness in the presence of noisy visual data, we incorporate Stein Variational Gradient Descent (SVGD) for particle-based probabilistic inference, generating multiple hypotheses for topological state estimation. Building on this foundation, we develop an autonomous dissection algorithm for thin-shell tissues that leverages topological updates to guide closed-loop cutting trajectory control. We evaluate our approach in both simulated and real-world electrosurgical environments, demonstrating significant improvements in topological estimation accuracy and dissection precision over existing methods. Our results highlight the potential of this framework to advance automation in soft-tissue surgical procedures by enabling reliable perception and control in the presence of complex structural changes.
Da Vinci adapters enable new robots for surgical research access
DASH: A da Vinci Adapter for Serial-link and Humanoid Robots as an Accessible Platform for Surgical Robotics Research
Abstract: Robotic minimally invasive surgery offers well-documented clinical benefits, but the cost and infrastructure requirements of purpose-built platforms limit access in rural and lower-resourced facilities. Recent work has teleoperated general-purpose robots for laparoscopic tasks and in vivo procedures, but relied on handheld instruments coupled through passive linkages rather than native robotic actuation. Instead, we adapt da Vinci Classic and Xi instruments onto general-purpose robots that can integrate in clinical workflows. We present DASH, a da Vinci Adapter for Serial-link and Humanoid platforms, consisting of two types of adapters that require no modification to the instruments themselves. Each adapter is compatible with many robotic platform load capacities, engages the instrument's native latch, and wirelessly identifies inserted tools to load instrument-specific kinematics and coupling matrices. Teleoperated experiments demonstrate the efficacy of DASH and its benefits for enabling research access to surgical robotic platforms.
Robotic system improves surgical removal of sticky small fragments
AGRO-SUVIDE: Agentic Robotics for Surgical Viscoelastic Debridement
Abstract: Augmented dexterity has the potential to reduce the fatigue experienced by surgeons during repetitive surgical tasks. In this paper, we propose the first AGentic RObotics framework for SUrgical VIscoelastic DEbridement (AGRO-SUVIDE), the repeated removal of small fragments attached to a viscoelastic substrate. Leveraging the self-improving and coding capability of agents, AGRO-SUVIDE adopts a modular framework. Specifically, the demonstration analysis module automatically identifies recurring skills from a single expert demonstration, using both visual and kinematic information. The construction module then builds each skill, either as a procedural model-based skill the agent codes against a scaffolded library or as a model-free policy-based skill. At runtime, the monitoring module composes the skills into a loop-style graph sized to the number of fragments it observes, then verifies pre- and post-conditions of each skill to decide whether to advance or retry. We evaluate AGRO-SUVIDE through 340 physical trials on the da Vinci Research Kit (dVRK). AGRO-SUVIDE achieves an average single-fragment removal success rate of 85%, completing consecutive three-fragment removal at 60% and at 95% with one human intervention. It further generalizes to unseen five-fragment scenarios with an average success rate of 80% for single-fragment removal. Project page: https://surgical-robotics.github.io/AGRO-SUVIDE/