MCP-Net enhances real-time navigation of coronary guidewires in robotic surgery

MCP-Net: Real-Time Coronary Perception Network and Topological Analysis for Robotic Guidewire Navigation

Abstract: Coronary guidewire navigation during percutaneous coronary intervention requires continuous interpretation of vessel anatomy, guidewire position, and target stenosis under two-dimensional X-ray fluoroscopy. While existing approaches commonly address vessel segmentation or device localization as separate tasks, a robotic system requires a more structured perception of the coronary scene to support downstream navigation. In this work, we present a simulation-driven framework centered on a Multi-Task Coronary Perception Network (MCP-Net) for robotic guidewire navigation, integrating coronary vessel segmentation, vascular topology extraction, and roadmap generation. Starting from three-dimensional coronary CT angiography, we generate simulated fluoroscopy images containing vascular structures, simulated guidewires, stenotic lesions with varying severity, and diverse vascular geometries, together with simulation-derived ground truth. MCP-Net jointly performs coronary vessel segmentation, guidewire-tip localization, and stenosis localization from a single fluoroscopic frame. These predictions are subsequently converted into a structured vascular graph containing centerlines, bifurcations, endpoints, branch directions, and branch angles. By associating the predicted stenosis with this graph, the framework generates a roadmap from the automatically selected graph root toward the target lesion. The results demonstrate that the proposed framework can jointly recover coronary perception targets and transform them into an interpretable vascular representation suitable for downstream robotic navigation.

Tue 27 OctComputer Vision and Pattern RecognitionRobotics
The gist
During heart procedures, doctors guide tiny wires through blood vessels using X-ray images to open blocked arteries. The authors present MCP-Net, a system that helps robots understand these X-ray images by identifying vessels, the wire tip, and narrowing spots all at once. They use realistic simulated images to train their system to then build a detailed map of the vessels and critical points. This map helps robots navigate precisely inside the coronary arteries during surgery.
Open → 2610.37127v1

Surgical point tracking improves accuracy using sparse endpoints and video data

STEP: Surgical Point Tracking from Sparse Endpoints and Pseudo-trajectories

Abstract: Surgical point tracking requires persistent correspondence through tissue deformation and occlusion, yet dense trajectory annotations are costly to obtain. We present STEP, a two-stage framework that learns from surgical video and sparse physical endpoints. First, a frozen offline teacher generates candidate trajectories, and temporal reversibility and stereo consistency select dense supervision for a causal student. Second, a robust physical endpoint loss anchors terminal correspondence, while a round-trip loss constrains temporal consistency. A gradient-free prefix exposes training to accumulated drift, while a final differentiable window bounds activation memory. The trained tracker processes a single RGB stream with fixed weights. In STIR-to-VL-SurgPT transfer, temporal-stereo union selection reduces endpoint error by 7.0% relative to unfiltered trajectories. On a post-hoc diagnostic of 29 VL-SurgPT clips excluded from the endpoint-training manifest, STEP reduces endpoint error from 31.52 to 16.80 pixels relative to dense-label fine-tuning. These results support combining curated trajectories with physical observations to train surgical point trackers.

Thu 22 OctComputer Vision and Pattern Recognition
The gist
Tracking points on surgical tools or tissue during operations is hard because the tissue moves and parts get blocked from view. The authors created a method called STEP that learns how points move using short, sparse annotations and video instead of relying on costly, dense tracking labels. STEP improves accuracy by combining physical endpoint information with video cues to maintain consistent tracking even when things shift or get hidden. This method can better track points in surgical videos without needing detailed manual labeling of every frame.
Open → 2610.31951v1

Endoscopic video pre-training improves tissue motion understanding

EndoWorld-JEPA: Motion-Guided Global-Local Latent World Modeling for Endoscopic Video Representation Learning

Abstract: Endoscopic video contains state transitions induced by camera displacement, deformable tissue, and instrument interaction, yet existing pre-training methods treat dynamics implicitly. Inspired by action-conditioned joint-embedding predictive world models and by the observation that endoscopic optical flow contains both shared image-plane displacement and localized residual motion, we reformulate passive endoscopic video pre-training as causal motion-guided latent-state prediction. We present EndoWorld-JEPA, to our knowledge the first latent world-model pre-training framework designed for general-purpose endoscopic video representation learning. In place of recorded actions, calibrated poses, or robot kinematics, the model conditions prediction of the next latent state on motion observed up to the current state. Its Optical Motion-guided module separates dominant displacement from residual motion and converts the resulting evidence into an ordered temporal motion condition and spatial local-motion weights. Complementary global and motion-local predictors use these outputs: the temporal condition modulates both latent transitions, whereas the local weights define an auxiliary motion-local state that extends prediction from scene-level evolution to spatially selective dynamics. Patch-wise motion weighting emphasizes localized change while retaining anatomical context, and past-motion-window dropout randomly withholds the complete motion condition to reduce dependence on unreliable motion. This global--local formulation learns predictable visual--motion dynamics in representation space without reconstructing stochastic appearance artifacts. Evaluation shows that a common pre-trained checkpoint achieves strong transfer across four downstream benchmarks, supporting motion-guided global--local latent prediction as an effective pre-training paradigm for endoscopic video.

Tue 20 OctComputer Vision and Pattern Recognition
The gist
Endoscopic videos show how the camera and tools move, but previous methods didn’t explicitly use these movements. The authors created a new way to learn from these videos by separating overall camera movement from small local tissue motions and predicting future changes based on that. Their approach improves how computer models understand these videos, helping them learn useful representations for other tasks. Tests show this method works well across multiple challenges involving endoscopic video analysis.
Open → 2610.27890v1

Thermal imaging helps robots cut tumors with less damage

Velocity Optimization via Thermal Imaging Enhances Autonomous Tumor Resection

Abstract: Objective: To demonstrate and evaluate THERMO, a thermal-velocity optimization algorithm for autonomous electrosurgery, in ex vivo porcine tissue using the UR10e-based ASTR system. Methods: Thermography for Electrosurgical Rate Modulation via Optimization (ThERMO), a closed-loop algorithm that uses real-time thermal imaging data to minimize thermal injury while ensuring accurate cut margins, was tested on ex vivo porcine tissue. Histological analysis was performed to detect thermal injury extent at a cellular level, and 3D photogrammetric measurement was used to verify margin accuracy. ThERMO's performance was compared against two previously used fixed velocity methods. Results: ThERMO outperformed both fixed velocity comparison methods without requiring data-driven training or iterative tuning, reducing thermal injury by up to 52%, improving cut accuracy by up to 59%, and maintaining task completion speed. Conclusions: Closed-loop thermal feedback via ThERMO improves autonomous robotic electrosurgery by simultaneously reducing thermal injury and improving margin accuracy, reinforcing its value over fixed velocity approaches for tumor resection applications. Significance: This work advances autonomous robotic tumor resection by demonstrating that real-time closed-loop thermal feedback control can substantially reduce collateral tissue damage and improve surgical margin accuracy.

Tue 20 OctRobotics
The gist
Cutting tumors with robots can accidentally harm healthy tissue because it's hard to control how fast and hot the tool moves. The authors designed a system called ThERMO that uses real-time heat images to adjust the cutting speed automatically. This makes cuts more precise and reduces heat damage without slowing down the surgery. The approach was tested on pig tissue and worked better than previous fixed-speed methods.
Open → 2610.27562v1

Autonomous guidewire navigation using 2D image feedback for endovascular surgery

A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework

Abstract: In endovascular interventions, physicians rely on planar DSA and X-ray fluoroscopy to interpret vessel anatomy and device motion, yet converting these images into feedback for autonomous navigation remains difficult. A perception and control method is formulated for two-dimensional image feedback. Vessel masks are converted into a labeled centerline graph, and device-tip estimates are projected onto a planned path to obtain progress, deviation, and direction. A rule-based controller uses these quantities for delivery, branch selection, probing, rollback, and recovery. The method was evaluated on a physical dual-device robotic platform in 65 closed-loop runs using simulator-rendered planar images across three paths. All runs reached at least 0.95 maximum observed guidewire progress; two runs (3.1%) met the prespecified failure rule of three or more autonomous stop events. The results establish route-level performance on the tested platform; clinical image sequences and broader anatomy remain to be evaluated.

Thu 15 OctRobotics
The gist
Doctors use two-dimensional X-ray images to guide thin tools through blood vessels during surgery, but it is hard to automate this process. The authors created a method that turns these images into a map and tracks the tool’s tip to understand how far and where it has moved. A rule-based system then controls the tool’s motion to follow planned paths and handle branches or obstacles. They tested this on a robotic setup using simulated images and showed reliable navigation along different vessel routes. Further testing on real clinical images and diverse anatomy is still needed.
Open → 2610.21481v1

Uncertainty learning improves segmentation accuracy at organ boundaries

Contrastive uncertainty learning for robust multi-structure segmentation in lower-pelvic MR

Abstract: Boundary delineation of anatomical structures in prostate MRI is often compromised by regional ambiguity. Automated segmentation methods relying on global overlap loss functions tend to be insensitive to surface deviations, leading to significant errors in ambiguous regions. Most existing uncertainty-aware methods treat uncertainty as a post-hoc quality indicator or prediction filter. We propose Contrastive Uncertainty Learning (CUL), a supervised framework that uses predictive uncertainty to directly guide representation learning. Using Monte Carlo Dropout, CUL identifies voxel-wise uncertainty and structures the embedding geometry accordingly: low-uncertainty, correctly predicted features form stable voxels while high-uncertainty or misclassified features are actively repelled, preventing feature collapse at difficult boundaries. We evaluate CUL on a 589-scan 3D prostate MRI multi-structure segmentation task (8 anatomical structures) using a ViT with UperNet decoder architecture. Average Dice ($83.38\%$) remains comparable to the baseline ($83.35\%$), while surface distance decreases significantly ($p<0.001$) across 6 of 8 anatomical structures. A hard-case analysis reveals a $22{\times}$ asymmetry between significantly improved and degraded cases ($18.8\%$ vs $0.9\%$). Ablation studies show that removing uncertainty-guided sample selection eliminates improvements for the transition zone, while replacing the contrastive objective with a boundary loss additionally removes bladder improvements, demonstrating that both uncertainty-guided sampling and the contrastive objective are essential for the observed gains. These findings demonstrate that the proposed uncertainty-guided representation learning is a useful mechanism for reducing the risk of extreme errors in safety-critical medical segmentation

Wed 14 OctComputer Vision and Pattern RecognitionMachine Learning
The gist
Segmenting different organs in prostate MRI scans can be tricky because boundaries between tissues are often blurry or unclear, causing mistakes. This paper presents a new method that uses the model’s own uncertainty to help it learn better features, especially around these difficult edges. By encouraging the model to focus on clear examples and separate uncertain or wrong predictions in its internal representation, it reduces errors near boundaries. The method was tested on almost 600 scans, showing similar overall accuracy but much better precision at organ surfaces, reducing risky mistakes.
Open → 2610.20251v1

Multimodal robotic system improves real-time surgical navigation accuracy

Multimodal Image-based Robotic Assistance and Guidance Environment (MIRAGE): A Novel Unified Framework for Surgical Navigation and Visualization

Abstract: This paper presents the computational architecture and quantitative preclinical evaluation of MIRAGE, a multimodal image-guided robotic surgery framework for real-time visualization and navigation. It integrates stereovision scene reconstruction, augmented-reality (AR) video overlay, quantified heads-up display (HUD) navigation, and intraoperative ultrasound within the da Vinci console's TilePro display (Intuitive Surgical). Additional modules include optical/electromagnetic tracker registration, stereo calibration, fiducial rigid registration with RMSE feedback, and 3D point-cloud reconstruction. Video I/O and rendering run in a C++ backend, while a Python GUI coordinates calibration, registration, reconstruction, visualization, and user interaction through an in-process zero-copy binding layer. The framework formalizes spatial transforms, module states, and synchronization of heterogeneous video and tracking streams. Preoperative calibration uses synchronized checkerboard image pairs and optimization, with estimated intrinsics, extrinsics, and rectification reused intraoperatively. MIRAGE was validated in phantom experiments across da Vinci S, Si, Xi, and SP platforms. Across clinically relevant working distances, mean 3D reprojection error was 0.6mm, with best 0.1mm RMSE at 100mm on Xi. Results support MIRAGE as a preclinical technical-validation platform for accurate, responsive, and extensible multimodal surgical guidance.

Thu 8 OctRobotics
The gist
Surgical robots need precise and real-time guidance to help surgeons operate safely. The authors developed MIRAGE, a system that combines multiple imaging techniques like 3D stereo vision, ultrasound, and augmented reality in one framework to assist surgeons during operations. They tested it on several versions of the da Vinci surgical robot, showing that it can provide very accurate visual guidance with errors of less than a millimeter. This technology helps surgeons see important information without interrupting their workflow, potentially making surgeries safer and more efficient.
Open → 2610.12780v1

Hall effect sensor detects touch forces for robotic surgery tools

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

Abstract: Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

Wed 7 OctRobotics
The gist
Surgeons using robotic tools can't feel what the robot touches, which makes delicate surgery harder. The authors created a tiny sensor that can be put on robotic tool edges to sense how hard and in which direction they’re pressing. Their sensor uses magnets and special detectors inside a soft material to measure forces accurately. They tested it with precise machines and on pig tissue to show it can feel forces during tasks like grabbing and slipping. This sensor could help robots give surgeons better touch feedback during minimally invasive surgeries.
Open → 2610.10346v1

Ultraworld improves autonomous ultrasound scanning with learned models

UltraWorld: Learning Interactive Ultrasound World Models from Untracked Clinical Videos with Acoustic Sampling Map

Abstract: World models can enable autonomous ultrasound scanning by predicting the outcomes of probe motions from local observations. Learning this action--observation relationship typically relies on synchronized video--pose pairs, which are costly to collect at scale and largely unavailable in routine clinical recordings. Reliable action following further requires modeling ultrasound's cross-sectional sampling geometry. We present UltraWorld, a self-distillation recipe that transfers priors from clinical ultrasound videos into interactive world models without real action annotations. Starting from clinical videos, we adapt a video foundation model into an ultrasound generator conditioned on reference images and anatomical masks. Anatomical masks sampled along programmable trajectories through 3D anatomy provide spatial guidance for synthesizing action--video pairs. We then use these synthetic pairs to self-distill the generator into a world model that predicts future observations from local observations and actions, without requiring anatomical masks or other 3D assets at inference time. To further improve action following, we introduce the Acoustic Sampling Map (AsMap), which represents probe poses and imaging settings as pixel-wise 3D sampling positions, beam directions, and depths. Experiments demonstrate improved prediction fidelity and action following. Across nine simulated closed-loop local planning episodes, UltraWorld reduces the mean final distance to the goal and orientation error by 29\% and 38\%, respectively, compared with visual servoing. Project Page: https://ultraworld-project.github.io/.

Wed 7 OctComputer Vision and Pattern RecognitionRobotics
The gist
Ultrasound scanning requires moving a probe and interpreting images, which is usually hard to automate because it's difficult to link probe movements to image changes. The authors of this paper developed UltraWorld, a method that learns how probe motions change ultrasound images by training on existing clinical videos without needing detailed motion data. They create synthetic training pairs of probe positions and images, then train a model that predicts future images based on probe moves. This helps robotic systems follow planned scanning actions more accurately, potentially improving autonomous ultrasound exams.
Open → 2610.09785v1

Deformable alignment method improves ultrasound and ct image matching

Deformable CT-US Registration via Anatomy-Aware Implicit Neural Representations

Abstract: Slice-to-volume registration between ultrasound (US) and preoperative computed tomography (CT) imaging would enhance many minimally invasive interventions, for example by locating soft tissue structures intra-operatively that are discernible in CT. While optical tracking enables initial rigid registration, contact from the probe induces soft tissue deformations that inhibit accurate alignment. In this work, we introduce a deformable CT-ultrasound registration framework that incorporates anatomical priors derived from CT to improve registration under deformation. Rigid registration is first established using a robot-assisted optical tracking system, after which a deformable transformation is estimated using a sinusoidal implicit neural representation (SIREN) optimized per frame. Tissue stiffness is approximated from CT-based HU values and used as spatially varying regularization, suppressing deformation in rigid structures such as bone while allowing more flexibility in soft tissue. Two additional constraints capture the physics of probe contact: a contact-zone displacement prior that drives the displacement field to compress tissue below the probe face, and a fan-geometry regularization term based on beam direction and convex transducer field of view. Model parameters are optimized with a normalized gradient field (NGF). The proposed approach improves alignment over rigid initialisation by 17% and outperforms classical deformable baselines while maintaining near-zero topological folding.

Tue 6 OctComputer Vision and Pattern Recognition
The gist
Ultrasound images taken during surgery need to be matched up correctly with pre-surgery CT scans to help doctors see soft tissues better. The authors developed a new method that not only uses a robot tracker to start the matching but also adjusts for the way soft tissues get squished during the procedure. They used a special math tool called an implicit neural representation that flexibly models these tissue changes while respecting harder tissues like bone. This approach made the matching more accurate than older methods, improving alignment by about 17%.
Open → 2610.08419v1

Robots improve control of deep soft tissue with causal sensing

CADeT: Causal-Aware Deformation Transmission for Indirect Robotic Manipulation of Soft Tissue

Abstract: Indirect manipulation of deep-seated deformable anatomy inaccessible to the robot is challenging in robot-assisted minimally invasive surgery (RAMIS) because intervening tissues spatially filter deformation transmission. Passive observations can be ambiguous because the Decoupled and Blocked modes may produce similar motion responses. We propose CADeT, a causal-aware deformation transmission framework that integrates structural causal model (SCM) with active sensing to infer a latent transmission mode and estimate a state-dependent adhesion Jacobian online. During normal manipulation, control actions update the mode belief; when ambiguity persists, an additional probing action is selected to improve mode distinguishability. The mode belief and learned Jacobian are incorporated into a belief-aware model predictive controller for indirect target-shape control. Validation in simulation and on the da Vinci research kit (dVRK), using phantom and ex vivo porcine tissues, shows higher mode-identification accuracy and faster shape-error convergence than the evaluated model-free and model-based baselines. These results show that active sensing improves mode identification and indirect deformation control under the evaluated conditions.

Tue 29 SeptRobotics
The gist
Indirectly moving soft tissues deep inside the body during robot-assisted surgery is hard because tissues between the robot and target tissue change how forces and movements travel. The authors created a new way called CADeT that helps the robot understand these hidden changes by using cause-effect models and special probing moves. This approach lets the robot guess what kind of tissue connection mode is active and learn how forces transmit in real time, improving the accuracy of controlling tissue shapes. Tests in both simulations and real tissue experiments show this method works better and faster than older methods.
Open → 2609.38483v1

Learning geometry-aware virtual guides from few demonstration points

Learning Geometry-Aware Virtual Fixtures From Sparse Demonstrations

Abstract: In many teleoperation applications, collecting a large number of demonstrations as required for traditional probabilistic learning from demonstration (LfD) approaches may not be feasible. To still give operators the ability to intuitively create trajectories as Virtual Fixtures (VFs), we propose to leverage a motion prior in the learning process. Particularly, by using Linear Quadratic Tracking (LQT), users are able to define guiding trajectories from the demonstration of just a few via points. To account for orientation guidance, we further reformulate classical LQT on Riemannian manifolds, introducing an additional geometric prior. Through a probabilistic interpretation of the LQT solution, we derive a covariance estimate at each trajectory point which we use to modulate the stiffness of the resulting fixture, resulting in strong guidance around the via points and softer guidance when far away. The covariance information is also used to define a validity region of the fixture, allowing the operator to leave its influence area and conduct unmodeled tasks. We evaluate the proposed Riemannian LQT formulation in a set of toy examples and the full framework on a cutting task requiring high precision in a minimally invasive surgery setting on the da Vinci Research Kit (dVRK).

Sat 26 SeptRobotics
The gist
Teleoperated robots help people perform tasks remotely, but teaching them precise paths can require many examples, which is hard to collect. The authors propose a method that uses just a few key points to teach these paths, while also guiding the robot's orientation using math that respects 3D geometry. Their approach adjusts how strongly the robot follows the guide depending on confidence, allowing the operator to work freely outside defined regions. They demonstrate their method on simple examples and a precise surgical cutting task using a robotic surgery platform.
Open → 2609.32958v1

Surgical tool pose estimation improves with projection and consistency optimization

PICO: Projection-Informed Consistency Optimisation for 6DoF Surgical Tool Pose Estimation

Abstract: Purpose: Accurate 6 DoF pose estimation of surgical tools is critical for automa- tion, robotic proprioception, and safe interaction with the tissue operated on. Kinematics-based approaches suffer from accumulated errors due to the cable- driven nature of robotic arms, while vision-based methods often rely on external markers or trackers. Although more recent vision-based advances have been pro- posed, these two-stage pose estimation methods often lack real-time robustness due to accumulated errors and computational overhead. Methods: We propose a novel end-to-end trainable model, PICO. Our model employs a multi-task learning architecture to predict segmentation and depth maps, alongside regression of translation and rotation parameters. We define two proxy tasks that enforce geometric consistency in both 2D and 3D spaces, improving accuracy and robustness. For this, we propose a projection loss, and a point-to-point loss. Results: We evaluate our method on the SurgRIPE dataset, benchmarking its performance against state-of-the-art approaches using standard 6DoF pose esti- mation metrics. Our results demonstrate consistently strong performance across all four subsets, specifically in rotation, ranking second even under occlusion. It also demonstrates comparable translational performance, remaining competitive, especially in occluded cases. Conclusion: PICO demonstrates the effectiveness of multi-task learning and geometry-aware proxy tasks for robust and reliable surgical tool pose estimation, especially in occluded scenarios, highlighting potential for future applications.

Fri 25 SeptComputer Vision and Pattern Recognition
The gist
Estimating the exact position and angle of surgical tools during operations is important for safe robot-assisted surgery. Existing methods either rely on arm mechanics that can accumulate errors or vision systems that need markers and can be slow. The authors propose a new AI model called PICO that learns to predict the tool’s shape and position together, using geometric rules to improve accuracy. Tests show PICO works well even when parts of the tools are hidden.
Open → 2609.30989v1

Digital twin vr system improves surgical robot teleoperation accuracy

Digital Twin-Driven VR Teleoperation with Multi-View Spatial Perception for Surgical Robots

Abstract: Current robot-assisted minimally-invasive surgery (RMIS) platforms provide a fixed console for the surgeon to view stereo endoscopic images and teleoperate instruments inside the patient. Several researchers have proposed the use of a head-mounted display (HMD) as a portable console, with video pass-through rendering of the endoscope images which, like the fixed console, restricts the operator to a single endoscopic viewpoint and limits depth perception. We present a digital twin-driven virtual reality (VR) teleoperation platform, where the digital twin is created from markerless perception of the surgical environment and streamed for display on the HMD. This overcomes the limitations of video pass-through by providing multi-view rendering and natural motion-parallax cues, enabling decoupling of the user's hand posture from strict instrument alignment. The system utilizes VR hand controllers to increase the teleoperation workspace and to improve the robustness and stability of instrument control compared to the hand tracking approach adopted by most prior systems. A 15-participant user study on the da Vinci Research Kit (dVRK) shows that our VR platform significantly outperforms a state-of-the-art HoloLens 2 mixed reality baseline, reducing path length by 86% and jerk by 95%, while achieving depth perception confidence comparable to or exceeding the traditional console across all conditions.

Tue 22 SeptRobotics
The gist
Surgical robots help doctors operate inside the body through tiny cuts, but current control setups only show the surgery from one view, making it hard to judge depth. The authors created a virtual reality system that uses a digital copy of the surgery area, letting surgeons see multiple angles and move naturally. This system also uses VR hand controllers for more precise and stable control compared to previous methods. Their tests showed the new system lets surgeons move instruments more smoothly and judge depth better than existing mixed reality systems and traditional consoles.
Open → 2609.25527v1

Surgical instrument segmentation improves using reasoning and queries

SIRA: Reasoning-Aware Surgical Instrument Segmentation via Query-Anchored Alignment

Abstract: Surgical instrument segmentation (SIS) plays a critical role in robotic assistance and surgical workflow analysis. However, most existing SIS methods formulate segmentation as a category-driven localization problem, limiting their ability to capture procedural context and task-dependent semantics in surgical workflows. We introduce Reasoning-Aware Surgical Instrument Segmentation (RA-SIS), a task formulation that frames segmentation as query-conditioned inference under surgical context. To benchmark this setting, we construct SurgRS, a surgical reasoning segmentation dataset consisting of 41,000 image-text pairs, which aligns instance-level masks with structured query-answer supervision to enable semantic grounding at the pixel level. Based on SurgRS, we propose Surgical Instrument Reasoning and Segmentation Assistant (SIRA), a multimodal framework that disentangles target-level and query-level semantics and integrates them with visual features through query-anchored dual alignment. By aligning query semantics with spatial features and segmentation prompts, SIRA enhances semantic-visual consistency in mask prediction. Extensive experiments on SurgRS demonstrate improvements over existing reasoning-aware baselines. Code is available at https://github.com/linxir226/SIRA.

Fri 18 SeptComputer Vision and Pattern Recognition
The gist
Identifying surgical instruments in images is important for robotic surgery and workflow analysis but often misses the procedure context. The authors propose a new way to segment instruments that understands specific questions about the surgery images, improving how well instruments are recognized. They created a large dataset pairing images with detailed questions and answers to help train and test this approach. Their new system, called SIRA, uses both the surgical context and visual clues to better predict where instruments are in images.
Open → 2609.21402v1

Visuomotor policy enables precise automated microelectrode hooking under a microscope

MicroHookACT: Monocular Microscopic Vision Guided Visuomotor Policy for Flexible Microelectrode Hooking

Abstract: Automated needle-loop hooking is a critical step in flexible microelectrode (FME) implantation. This paper presents MicroHookACT, an imitation learning-based visuomotor policy for automated 3D hooking under monocular microscopic vision. First, a unidirectional hooking strategy exploits defocus cues and optical-axis guidance to enable palpation-free precise alignment and contact-rich threading. Second, an action-supervised object attention module built on a frozen ViT backbone learns to focus on the micro-needle tip and micro-loop directly from human demonstrations, without requiring manual visual annotations for training. Third, attention-centered global coarse and local fine features are dynamically weighted according to predicted action progress, enabling a single ACT policy to adapt to changing defocus blur and visual requirements throughout the operation. In the experiments, visuomotor policies were trained on 60 human demonstrations and evaluated under five setups with varying difficulties. Our MicroHookACT framework achieved the highest overall success rate of 96.7\% with an average execution time of 11.5 s. These results demonstrate the potential of visuomotor policy learning for micron-level control under varying operating conditions.

Fri 18 SeptRobotics
The gist
Placing tiny flexible microelectrodes inside the body requires a tricky step called needle-loop hooking. The authors developed MicroHookACT, a computer program that learns from human demonstrations to control a microscopic camera and robotic actions for this task. It uses visual clues like blur and focus changes to align and hook the microelectrode precisely without touching the surface. Their approach succeeds 96.7% of the time across various setups and completes the task quickly. This shows that teaching robots to see and act like humans can improve precise control in tiny surgical tasks.
Open → 2609.21365v1

Parallel robot trajectory smoothing improves pancreatic surgery control

Towards AI-enhanced control: a numerical technique for trajectory smoothing of a parallel robot for pancreatic surgery

Abstract: The paper presents a numerical approach for the end-effector trajectory smoothing of a parallel robot designed for minimally invasive pancreatic surgery. The approach is tailored for real-time master-slave control architecture and uses a 3D space mouse for command input for velocity control. The trajectory smoothing is achieved by generating S-curves in the end-effector velocity fields, thus controlling the accelerations, which in turn reduces tissue trauma in the minimally invasive procedures. Real-time control is enabled by segmenting the S-curves based on the command inputs from the 3D space mouse. A special case is considered where the acceleration time is constant for all command inputs. Numeric results demonstrate stable transitions (without abrupt changes) in both the end-effector parameter space and in the active joints parameters, thereby validating the proposed approach. Further work aims to test the approach on an experimental model and integrate it into AI-based training modules.

Thu 17 SeptRobotics
The gist
Smooth robot movements help reduce harm during delicate pancreatic surgeries. The authors developed a method that makes these robot arm movements smoother by controlling how fast and how quickly they change speed. This system uses a 3D space mouse to control the robot in real time, ensuring gentle and steady motions. Their tests showed this approach avoids sudden jerks, making the robot safer and more precise in surgeries.
Open → 2609.20499v1

Scene graph driven haptic feedback improves precision in robotic eye surgery

Scene Graph-Driven Haptic Feedback for Safety Enhancement in Robotic Ophthalmic Surgery via Physically Simulated iOCT

Abstract: Robotic ophthalmic surgery offers high precision but introduces a "sensory gap" by decoupling the surgeon from their instrument, resulting in a loss of tactile feedback. This paper presents a novel haptic feedback system for subretinal injection tasks leveraging Scene Graphs (SG). The system bridges the sensory gap by analyzing a physically simulated intraoperative Optical Coherence Tomography (iOCT) feed to construct a real-time surgical SG. The SG serves as a semantic abstraction layer for the surgical scene, which is then utilized by a deterministic, rule-based engine to generate state-dependent haptic feedback on a robotic input device. The system was evaluated in a user study (N=16) using an anthropomorphic head phantom and a custom-built surgical robot. Results demonstrate that the SG-driven haptic feedback improved surgical precision, reducing needle alignment error by 14% (p = 0.044) and improving System Usability Scale (SUS) scores by 8% (p = 0.015), while maintaining comparable task completion times. A needle trajectory analysis revealed the emergence of a safer "Align-then-Approach" strategy, in which our haptic negative reinforcement prompted users to fine-tune the tool's trajectory before approaching the retinal target. This work suggests that SGs can effectively serve as the direct computational foundation for real-time, safety-enhancing context-aware haptic feedback in robotic microsurgery.

Mon 7 SeptRoboticsComputer Vision and Pattern Recognition
The gist
Robotic eye surgery is very precise but makes it hard for surgeons to feel what they are doing because they lose the sense of touch. The authors created a system that uses a special way to understand the surgical scene, called a scene graph, by analyzing simulated images from an eye scanner. This system then gives surgeons gentle vibrating feedback so they can better control the needle during surgery. In tests, this feedback helped surgeons align their tools more accurately and use safer movements without taking longer.
Open → 2609.07857v1