Catheter tip position estimated more accurately without shaft sensors

Shaft-Configuration-Adaptive Catheter Tip Position Estimation via Motor-History Conditioned Residual Learning

Abstract: Tendon-driven continuum manipulators are widely used in medical applications, where accurate tip-position estimation is essential for precise navigation and instrument positioning. However, patient anatomy and procedural setup impose task-dependent unknown shaft configurations, while friction, slack, and compliance introduce hysteresis, making tip estimation challenging. This paper presents a motor-history-conditioned gated recurrent unit (GRU) residual estimator for three-dimensional catheter tip estimation without direct shaft-configuration sensing. First, an initial multidirectional sweep strategy is applied to calibrate a geometric catheter model backbone, and encode the motor-angle and drive-torque response into a shaft-configuration context vector. During subsequent motion, the context conditions a GRU that predicts a task-space residual correcting this backbone, relying on motor measurements alone. The context remains fixed for the current shaft configuration, while the recurrent state captures the evolving actuation history. Across four disposable intra-cardiac echocardiography catheters and 16 bent shaft configurations, the method achieves 3.3mm open-loop tip RMSE, a 59% reduction relative to the constant-curvature baseline.

Tue 22 SeptRobotics
The gist
Accurately knowing the tip position of flexible medical catheters is hard because the shape of the catheter shaft changes and friction causes errors. The authors designed a method that learns from the motor controls and their past motions to better predict the catheter’s tip location in 3D space without needing extra sensors on the shaft. They first calibrate a simple geometric model with a special motor sweep and then use a recurrent neural network to correct that model during use. This method reduced errors by over half compared to traditional models.
Open → 2609.26304v1

Earable tooth-click control helps neurosurgeons operate hands-free

NeuroClick: Preserving Surgeon Autonomy through Hands-Free Earable Tooth-Click Control in Neurosurgery

Abstract: Neurosurgeons frequently interact with operating room (OR) technologies while sterility and occupied hands constrain control. We introduce earables as a direct, hands-free control platform for neurosurgery using tooth-click input. Formative OR observations and interviews with 10 domain experts grounded the design. Using OpenEarable 2.0 data from 12 participants, we developed a real-time recognition pipeline whose classifier achieved a median macro F1-score of 98.6% under leave-one-subject-out cross-validation. We evaluated the technique with 20 neurosurgeons during a simulated resection task in a neurosurgical OR. Participants reported few focus shifts and rated Earable favorably for workflow integration and perceived safety. Autonomous microscope control was rated significantly higher with Earable than Delegation, whereas Delegation enabled faster task completion under continuous assistant availability. Workload, usability, and task errors showed no significant differences. Preferences depended on training, reliability, context, and assistant availability. Earables thus add a direct, hands-free option for controlling selected functions alongside established workflows.

Fri 11 SeptHuman-Computer Interaction
The gist
Operating rooms can be challenging for neurosurgeons because their hands are busy and must stay sterile, making it hard to control equipment. The authors introduced a tiny device worn on the ear that listens for special tooth-click sounds to control devices hands-free. They trained a computer program to recognize these clicks with very high accuracy and tested it with real neurosurgeons during a simulated surgery. Surgeons said it was easy to use and felt safe, and it helped them control the surgical microscope without relying on an assistant all the time.
Open → 2609.12910v1