Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Surgical phase recognition improves accuracy and stabilizes workflow predictions
Shifted Window Temporal Transformer for YOLO-Guided Phase Recognition in Laparoscopic Cholecystectomy Surgery
Abstract: Intelligent operating rooms require accurate awareness of surgical workflow for better intra-operative decisions, teamwork, and surgical documentation. Therefore, accurately recognizing surgical phase during surgery is crucial. However, previous artificial intelligence-based methods provide fluctuating predictions for the transitions, restricting their clinical use. To address this challenge, we propose a clinically meaningful framework that integrates a Swin Transformer and Temporal Transformer Encoder (TTE) for effective surgical phase recognition and a parallel YOLOv11s network for real-time surgical instrument localization. To avoid phase flickering and to produce stable workflow predictions, a causal temporal smoothing is applied. The proposed framework is tested on the Cholec80 dataset for the simultaneous recognition of the surgical phases and instruments. The overall phase recognition accuracy of this model was 92%, and the macro average F1-score was 0.86. This performance surpasses CNN based methods such as EndoNet (81.7%) and SV-RCNet (85.3%), as well as temporal convolutional and transformer-based approaches including TeCNO (88.6%), Trans-SVNet (90.9%), and LoViT (91.5%). Besides, the module of instrument detection achieved mAP@0.5 = 0.863. The reliability of the results is confirmed, obtaining a high recognition rate of the workflows, and a high accuracy of the localization of the instruments. The proposed framework can serve as a foundation for intelligent surgical assistance, enriching situation awareness, and potential robotic surgery applications. Code will be made publicly available at: https://github.com/ac005sheekar/LapChol-Surgery-Swin-Cholec80
Multimodal AI improves surgical tool bounding box labeling at scale
From Presence Labels to Bounding Boxes: Can Multimodal Large Language Models Scale Surgical Instrument Localization?
Abstract: Spatial localization of surgical instruments through bounding-box annotations is a foundational component of surgical scene understanding, supporting detection, tracking, interaction analysis, and grounded vision-language applications. Yet existing annotations often cover selected frames, video subsets, or dataset variants rather than complete procedures. Manual extension is time-consuming and expert-dependent. Additionally, weakly supervised and detector-based pseudo-labels require task-specific training and may be imprecise. In this study, we design a scalable MLLM-based annotation framework that converts surgical frames and existing instrument-presence labels into accurate bounding boxes, and systematically analyze its reliability, cost, and design sensitivity. We instantiate the framework using six MLLMs and a multi-call configuration on laparoscopic cholecystectomy in Cholec80. Using a carefully designed stratification scheme, two annotators independently label 1,000 frames, and an expert surgeon reviews one annotation set to establish the reference. Results show that instrument-set F1 ranges from 88.2 to 92.7,whereas mIoU ranges from 0.180 to 0.735, showing that comparable recognition can conceal large localization differences. A structured multi-stage annotation pipeline achieves 0.784 mIoU, compared with 0.735 for the best single-call baseline and 0.814 human-human agreement. Using the best accuracy pipeline, we create and publicly release a spatial extension of Cholec80 comprising 285,977 bounding boxes across all 184,498 annotated frames from the 80 videos. The annotations and human references are made available on GitHub
Vr training improves robot guidewire control and feedback in vascular navigation
A VR Training System for Robot-Assisted Vascular Intervention with Dual-Mode Control and Model-Based Interaction Response
Abstract: Virtual reality training for robot-assisted vascular intervention requires accurate robotic control and effective feedback on guidewire--vessel interactions. This paper presents a VR training system combining asynchronous dual-mode command mapping with sensorless interaction estimation. The system supports velocity-controlled navigation and position-driven incremental manipulation. Guidewire deformation and a Hunt--Crossley-type contact response are combined and temporally filtered to estimate interaction intensity, while trajectory-based visualization supports post-procedure review. Tests confirmed distinct command-dispatch patterns across three velocity gears and the position mode. During hybrid-scene navigation, the estimated response remained low during straight insertion and increased as the guidewire bent within the vascular model. Trajectory analysis yielded a model-derived cumulative trauma work (CTW) value of 15.166 in normalized units and localized regions of elevated interaction. In a preliminary study with 15 novices, physical-phantom task success increased from 53.3% to 93.3% after VR training, while mean completion time decreased from 132.4 s to 96.7 s. These results demonstrate the system's dual-mode operation, deformation-sensitive feedback, and potential to improve subsequent physical-phantom task performance.
Belief-based model tracks catheter tip with less X-ray exposure
A Belief-State World Model for Catheter Navigation under Sparse Fluoroscopy: A Planar Proof of Concept
Abstract: Endovascular catheter navigation relies on continuous fluoroscopy, exposing patients and clinical staff to ionizing radiation throughout the procedure. We investigate whether a physics-based world model can sustain the navigation task between deliberately sparse X-ray acquisitions, and whether the model can signal when its internal state estimate is no longer reliable. We formulate sparse-fluoroscopy navigation as a partially observable Markov decision process where a Cosserat rod simulator supplies transition dynamics, sparse noisy projections provide observations, and a particle filter maintains a belief over the device state, reduced in this implementation to a tip state with a geometric contact proxy. We evaluate this formulation in a deliberately simplified setting: a synthetic planar vessel phantom with a quasi-static rod model and simulated projections, without clinical or animal data. In this setting, the belief-state model tracks the simulated tip with a root mean square error of 1.30 mm while acquiring observations at one fifteenth of the continuous rate (0.97 mm at every frame, 1.51 mm at one thirtieth), reported 90 percent credible intervals achieve 0.92 empirical coverage, and the belief-derived contact risk estimate discriminates unsafe contact events with an AUROC of 0.68. These results constitute a proof of concept on a simplified simulation rather than a demonstration of clinical readiness; their purpose is to establish that calibrated belief, rather than point-estimate accuracy alone, is the essential property a sparse-imaging world model must deliver.
Ultradiff enables shape optimization with differentiable ultrasound ray tracing
UltraDiff: Differentiable Ray Tracing in Ultrasound for Shape Optimization
Abstract: Physically-based differentiable rendering enables gradient-based optimization of scene parameters by matching rendered images to measurements, but has so far mainly focused on light transport. We extend this paradigm to medical ultrasound, where image formation resembles transient rendering: echoes are binned by time-of-flight rather than projected onto an image plane. We present UltraDiff, a modular framework for differentiable ultrasound ray tracing. UltraDiff formulates ultrasound image formation as a path-space integral, gated by travel time between the transducer and tissue interfaces, and derives a Monte Carlo estimator of both the forward model and its gradients with respect to scene parameters. We demonstrate this on an inverse geometry estimation: starting from a sphere, an SDF is optimized until simulated echoes match measured ones, recovering vertebral surfaces from simulated B-mode sweeps and from a real robotic acquisition of a spine phantom. Unlike state-of-the-art ultrasound shape reconstruction methods, which rely on pre-segmented images, our approach operates unsupervised on B-mode images through analysis-by-synthesis, while achieving competitive geometric accuracy. Implemented on top of Mitsuba 3, UltraDiff brings differentiable path tracing to a new sensing modality and provides a foundation for inverse problems in acoustic imaging.
Soft tissue cutting simulation captures deformation damage and tool interaction
STC-MPM: Coupled Deformation, Progressive Damage, and Cut Formation in Soft-Tissue Cutting
Abstract: Cutting is a recurring operation in robotic au tomation, from food preparation to surgical tissue resection. For highly compliant targets, blade motion may deform or displace the material rather than advance the intended cut, while progressive failure changes load transfer and subsequent tool tissue interaction. A computational description must therefore connect cut formation to the evolving mechanical response, rather than specifying the incision independently of material failure. We present STC-MPM (Soft Tissue Cutting with the Material Point Method), a framework that couples finite-strain deformation, history-driven continuum damage, and configurable post-failure treatment. Damage initiates only when a tensile strain history exceeds a material threshold within the blade process zone. Progressive degradation changes stress transmission before the post-failure policy is applied, while the remaining tissue continues to deform, move, and interact with the tool. Numerical scalpel studies using delayed particle deactivation follow this response through insertion and withdrawal. Under identical blade motion, reducing the damage-rate limit leaves the first recorded damage time unchanged but delays and increases peak reaction force, delays particle deactivation, and increases the fixed-cohort displacement statistic at maximum insertion. The matched comparison illustrates how post-initiation failure evolution alters subsequent tool loading and recorded material motion. STC-MPM thus supports joint analysis of cut formation and accompanying tissue response without a pre-inserted cutting interface.
Surgical instrument tracker captures precise hand movements without magnets
Recording Hand-Held Laparoscopic Instrument Motion in the Operating Room: Magnetometer-Free Fusion of Inertial, Range and Visual Sensing
Abstract: Most minimally invasive procedures are still performed with hand-held laparoscopic instruments, yet only the endoscopic video is retained; the instrument motion that expresses surgical skill, and that could support skill assessment and robot learning, is lost. Pose from video alone remains millimeters to centimeters off, and an instrument-mounted inertial measurement unit (IMU) cannot rely on its magnetometer, whose field changed with tool pose and between sessions in our measurements. We present a surgical instrument-state logger that clips onto a conventional instrument without modifying the part that enters the patient and fuses a six-axis IMU and a time-of-flight (ToF) rangefinder with a markerless camera in an error-state Kalman filter under the remote center of motion (RCM) of the trocar. Heading comes from the shaft silhouette, segmented by a U-Net, in place of the magnetometer: the rotation-angle error is 0.200°, against 3.58° from the accelerometer and magnetometer alone. Against a Franka Research 3 manipulator, and without alignment to it, the displacement error over 300 translation trials was 1.21mm RMS and the relative-rotation error over 180 rotation trials 0.34° RMS. On continuous trajectories, tracked and displayed in real time, the absolute tip error was 1.22mm (programmed) and 3.04mm (teleoperated) after post-hoc tuning of three filter parameters, and the full fusion beat every sensor subset. Because the estimator uses no magnetic measurement, its accuracy does not rely on an undisturbed field. The same clip-on device could thus record metric tip trajectories during routine hand-held laparoscopy, while displaying the insertion depth and attitude that are hidden once the instrument is inside the patient.
Curated liposuction dataset captures expert surgeon’s motion and forces
HumynexSurg-1: A Curated Expert Liposuction Dataset
Abstract: Robot foundation models learn manipulation from large demonstration corpora, but surgery is missing from those corpora: across the 780-hour Open-H surgical collection, one dataset carries synchronized force and none covers an aesthetic procedure. Liposuction is the hard case, because the instrument works under the skin and the surgeon operates by feel and by judgment. Humynex Robotics builds curated expert datasets for this kind of procedure. HumynexSurg-1 is the first release: a master liposuction surgeon performing on porcine abdominal tissue while narrating every decision, recorded with synchronized suction pressure, six-axis hand force/torque, top-down RGB-D video, side video and a lavalier microphone -- 14 episodes, 42,738 frames, 35.6 minutes, 356 utterances of which 95% compile into a liposuction-specific label schema. The capture follows a patent-pending sensing plan organized around the quantities a policy needs, so a channel captured today by a model can be upgraded to a sensor tomorrow without changing the data format. This release captures the instrument motion as a tool-hand track in the side video and provides the force channel as state; the funded capture adds a measured 6-DoF handle pose, a validated force channel, ultrasound imaging of the fat layer, and palpation sensing. As a proof of concept, NVIDIA Isaac GR00T N1.7 fine-tunes on the dataset with no custom code in under an hour per run and learns the recorded sessions; scaling probes on the same episodes show where further gains come from: every new session lowers the error on an unseen session. The dataset, its label schema, its quality-assurance reports and its evaluation protocol are the product; the next capture, many short sessions across fat regions with the sensors named here, is what the probes point to.