Papers for
radiology software engineers
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Tim improves radiology reports by tracking disease changes over time
TIM: Temporal Decoupling with Iterative Mutual-Refinement Model for Longitudinal Radiology Report Generation
Abstract: Automatic radiology report generation (RRG) aims to translate medical images into diagnostic text, reducing radiologists' workload and standardizing clinical documentation. Nonetheless, existing approaches mainly focus on single-timepoint analysis and fail to capture temporal disease evolution across longitudinal examinations. While recent longitudinal RRG (LRRG) approaches incorporate historical data, they often combine images from different time points within a single representation space, leading to blurred semantics and inconsistent temporal reasoning. In this work, we propose a Temporal Decoupling with Iterative Mutual-Refinement Model (TIM), a two-stage framework that explicitly decouples spatial pathology from temporal progression and iteratively refines reports through mutual feedback. Stage I performs temporal-decoupled representation learning, separating temporal evolution patterns from disease-specific features and generating radiology reports for both prior and current studies. Stage II introduces a mutual report refinement mechanism that identifies diagnostic inconsistencies within prior reports and iteratively rectifies both prior and current reports through error-sensitive feedback. Experiments on the Longitudinal-MIMIC dataset demonstrate that TIM surpasses existing single-image and longitudinal baselines, achieving new state-of-the-art performance across both language and clinical metrics. Code is available at https://github.com/yihengd/TIM.
Lightweight AI model reduces noise in low-dose chest X-rays fast
Denoise X: Self-Supervised U-Net for Quantum Mottle Suppression in Chest Radiography
Abstract: Deep learning for medical image restoration is often constrained by the need for paired training data. Acquiring perfectly registered clean-noisy radiographs in vivo is impractical due to patient motion and radiation-dose limits. To address this, we employ a self-supervised Noise2Noise paradigm that trains on independently corrupted observations without paired clean images. We propose Denoise X, a lightweight self-supervised U-Net model (7.79M parameters) for suppressing quantum mottle and electronic readout noise in low-dose chest radiographs. It is trained on the NIH ChestX-ray14 dataset (112,120 images) using a stochastic Poisson-Gaussian noise simulator. Zero-shot evaluation on the unseen Montgomery County dataset achieved a PSNR of 36.09 dB and SSIM of 0.8806, outperforming the Bilateral filter while preserving high-frequency anatomical details. Using patch-wise inference, Denoise X processes native-resolution chest radiographs in ~2.2 s per image on a Tesla P100 GPU. Cross-domain evaluation on the Shenzhen dataset achieved 36.44 dB PSNR and 0.9099 SSIM, showing strong generalization. For resource-constrained deployment, the model was converted into a 31.16 MB ONNX model for efficient CPU inference on non-DICOM images.
Medical image models learn clearer signs of diseases using geometry
$Δ$Representation: Geometry Supervised Representation Learning of Phenotypes via Counterfactual Reasoning for Medical VLMs
Abstract: Medical vision-language models (VLMs) have shown increasing potential for radiological image interpretation. Medical VLMs encode radiological images into visual representations that capture both anatomical and phenotypic information for diagnosis. Existing approaches improve pathological phenotype representations through semantic-guided representation alignment. However, pathological phenotypes arise as lesion-specific visual changes superimposed on underlying normal anatomy. Such semantic alignment approaches fail to model the phenotype-specific increment relative to the corresponding normal anatomical representation. To address this gap, we propose \textbf{$Δ$Representation}, a visual phenotype representation learning framework based on counterfactual reasoning for medical VLMs. It comprises \textbf{BaseAnatomy}, a geometry-supervised representation learning module, and \textbf{$Δ$Phenotype}, a counterfactual incremental representation learning module. BaseAnatomy provides fine-grained geometric supervision through spatial relationships across and within anatomical structures. $Δ$Phenotype computes the representation increment between lesion representations and their corresponding normal anatomical representations, and supervises increments associated with the same phenotype to cluster in the representation space. Experiments on \textit{ReXGroundingCT} and \textit{LIDC-IDRI} demonstrate that $Δ$Representation effectively structures pathological phenotype representations and improves lesion grounding and phenotype characterization accuracy in medical VLMs. Code is available at https://anonymous.4open.science/r/deltarep-CF6D.
Geometry guided learning improves medical image lesion interpretation
Geometry-Supervised Visual Representation Learning for Multi-Phenotype Lesion Interpretation in Medical VLMs
Abstract: Medical vision-language models (VLMs) have shown increasing potential for clinical image interpretation. However, these models still struggle to interpret multi-phenotype lesions whose diagnosis requires the joint assessment of multiple pathological phenotypes. Existing vision-language alignment methods produce visual representations that fail to preserve anatomical hierarchies and relationships among phenotypic subclasses. This stems from their reliance on semantic supervision, which lacks geometric constraints to preserve these relationships in the visual embedding space. Moreover, the sparsity of lesion-related anatomical and phenotypic representations makes it difficult for medical VLMs to capture important diagnostic evidence. To address these limitations, we propose \textbf{PureVision}, a geometry-supervised visual representation learning framework for multi-phenotype lesion interpretation in medical VLMs. It combines a geometry-supervised representation learning module, \textbf{PureEyes}, and an anatomy-guided evidence aggregation module, \textbf{PureNeurons}. PureEyes provides geometric supervision through ideal spatial distributions that encode anatomical hierarchies and phenotypic subclass relationships. PureNeurons projects visual representations into the learned latent space, using their positions to selectively aggregate lesion-specific anatomical and phenotypic evidence. Experiments on \textit{LIDC-IDRI}, \textit{CBIS-DDSM}, and \textit{3DReasonKnee} demonstrate that PureVision improves lesion grounding and phenotype characterization in visual question answering and radiology report generation. Code is available at: https://anonymous.4open.science/r/purevision-06C2.
BrainMRI benchmark tracks evidence for longitudinal interpretation
BrainTRACE: Tracing Longitudinal, Multimodal, and Volumetric Evidence in Brain MRI Clinical Reasoning
Abstract: Brain MRI interpretation is a longitudinal clinical reasoning problem: radiologists compare serial studies, integrate information across MRI sequences, localize findings within volumetric anatomy, and translate this evidence into report-grounded assessments. Existing medical VQA and 3D imaging benchmarks capture important parts of this workflow, but often evaluate brain MRI through isolated images, static volumes, or ungrounded report-style answers, thereby obscuring failures in the evidence chain that support clinical validity. We introduce BrainTRACE, a report-grounded benchmark for evaluating whether vision-language models can trace the evidence structure required for longitudinal brain MRI interpretation. BrainTRACE contains 7,273 scored VQA instances derived from 1,778 longitudinal patients, 7,299 MRI studies, and approximately 29k co-registered 3D MRI sequence volumes. The benchmark is organized by five levels of clinical reasoning, from acquisition recognition to case-level synthesis, and by evidence demands covering longitudinal comparison, report-grounded references, multi-sequence integration, and volumetric spatial evidence. BrainTRACE supports rendered inputs compatible with standard VLM interfaces, a 3D-evidence condition, and a decomposed case-reasoning track that audits six steps in a longitudinal evidence chain. Evaluation of 20 VLM configurations shows that current systems can identify isolated visual cues but rarely compose them into grounded longitudinal interpretations. We release the benchmark specification, evaluation lists, scoring implementation, scoring rubrics, and audit-record format to support reproducible progress in brain MRI VLM evaluation.
Saliency methods show limits in explaining breast MRI AI decisions
Faithful Faithfulness Evaluations: Challenges & Pitfalls Learned from a Breast MRI Case Study
Abstract: Saliency maps are widely used to explain deep learning predictions in medical imaging, yet visually plausible explanations do not necessarily reflect a model's true decision process and may therefore mislead clinicians. We investigate this problem using a Vision Transformer-based breast MRI classifier trained on the ODELIA Breast MRI Challenge dataset and evaluate multiple saliency methods, including Last-layer Attention, Attention Rollout, Grad-SAM, Gradient Attention Rollout, GMAR, Grad-CAM, and HiResCAM. Our study highlights two often-overlooked challenges in perturbation-based faithfulness evaluation. First, method rankings depend strongly on the perturbation strategy, varying across intensity-based perturbations and transformer-based attention masking. Second, benchmarking saliency methods requires distinguishing between class-specific and class-agnostic explanations. To enable fair comparisons, we introduce non-class-specific variants of gradient-based methods and evaluate both settings separately. Across protocols, Grad-CAM and Gradient Attention Rollout consistently emerged as the strongest class-specific methods, although their relative ranking depended on the evaluation design. These findings expose important limitations of current saliency-based explainability approaches and highlight the need for more robust and standardized evaluation frameworks for trustworthy clinical AI systems.
Graph method improves medical image analysis across slices
G^2RA-NET: Graph-based Cross-Slice Relation Modeling with Attention Gating for Medical Image Segmentation
Abstract: Medical image segmentation supports quantitative clinical analysis and computer-aided diagnosis. Recent methods for medical image segmentation have improved both local feature representation and volumetric context modeling. However, existing methods still strug- gle to efficiently model cross-slice relations in anisotropic volumet- ric images, limiting segmentation consistency and accuracy. This pa- per proposes G^2RA-Net, a medical image segmentation framework that combines graph-based cross-slice relation modeling with atten- tion gating. Graph-Based Slice Relationship Modeling (GSRM) cap- tures anatomical dependencies across consecutive slices by repre- senting each slice as a graph node and propagating semantic con- text through graph message passing. The Cross-Slice Attention Gate (CSAG) then selects relevant neighboring context and emphasizes target anatomical regions through attention-guided feature modula- tion. Experiments on brain MRI and abdominal CT datasets demon- strate that G^2RA-Net outperforms representative methods in seg- mentation accuracy and boundary quality. Ablation studies further validate the proposed design.