Sparse view 4d cbct reconstruction minimizes radiation and scan time

Dual-Domain Sparse-View 4D CBCT Reconstruction with Spatial-Temporal Consistency Learning

Abstract: Four-dimensional cone-beam computed tomography (4D CBCT) provides phase-resolved volumetric images for image-guided radiotherapy. Yet good reconstruction quality usually needs many projections. This increases scan time and radiation dose. We propose STCNet, a sparse-view 4D CBCT reconstruction framework that uses spatial-temporal consistency learning. STCNet reconstructs high-quality images from only 16 projections in each respiratory phase. STCNet integrates physics-driven positional encoding to enforce geometric consistency in the projection domain and introduces temporal encoding in latent space to capture respiratory motion dynamics across phases to capture dynamic respiratory motion across phases. A dual-domain collaborative strategy jointly optimizes both projection and image domains, enhancing structural fidelity and temporal coherence. We tested STCNet on the TCIA-LUNG dataset and a CIRS thorax phantom dataset. STCNet performed better than conventional methods and recent deep learning baselines in image quality, artifact reduction, and structural preservation. On TCIA-LUNG, STCNet reached PSNR values of 33.311, 32.695, and 32.658 dB at phases 2, 5, and 8. The corresponding SSIM values were 0.845, 0.823, and 0.825. On CIRS, STCNet achieved PSNR values up to 36.497 dB and SSIM values up to 0.877. These results support STCNet as a promising framework for low-dose, phase-resolved 4D CBCT reconstruction in image-guided radiotherapy.

Tue 13 OctComputer Vision and Pattern Recognition
The gist
Medical imaging using 4D cone-beam computed tomography (CBCT) usually requires many X-ray images, which increases scan time and radiation exposure. The authors propose STCNet, a new method that produces high-quality 4D CBCT images using only 16 X-ray views per breathing phase. They use smart encoding techniques to keep the images consistent in space and time, helping capture motion from breathing accurately. Tests on lung and thorax datasets show that STCNet creates clearer images with fewer artifacts than existing methods, potentially enabling safer and faster scans for patients.
Open → 2610.18518v1

QureRadEmbed improves radiology report comparison and search accuracy

QureRadEmbed: Structuring Radiological Similarity through Attribute and Reasoning Supervision

Abstract: Radiological similarity depends on disease relationships and on fine details such as laterality, lobe, severity, size, and certainty. Broad biomedical similarity can overlook these qualifiers, particularly when several attributes vary together. We introduce QureRadEmbed, a 4B radiology-aware encoder trained with two complementary signals: RadSim supplies deterministic, attribute-decomposed ranking targets, while RadThought aligns reports with hierarchical evidence and reasoning descriptions. A three-stage curriculum combines these signals with report triplets, finding perturbations, and single- and cross-attribute contrasts. The final model achieves 0.996 mean ordering accuracy across ten controlled synthetic attributes and raises Spearman correlation with the designed joint-attribute targets from 0.501 to 0.976. On external findings-to-impression retrieval, Recall@1 reaches 10.5% on Open-I, 12.4% on testing XR, and 42.9% on testing CT, compared with 6.6%, 5.7%, and 31.4% for its backbone. Frozen embeddings support finding extraction with only 100 labeled testing-XR reports (macro-F1 0.481 versus 0.412 for the backbone). Whole-report comparison costs 8.8 seconds per 1,000 pairs in our benchmark, versus 2,755.1 seconds for the generative evaluator GREEN. Sentence-level comparison improves sensitivity to local discrepancies, although generative evaluation remains stronger on several expert-rated and subtle-error tasks. The results support reusable radiology-aware representations for search, structured report indexing, and efficient report comparison.

Sun 27 SeptArtificial Intelligence
The gist
Radiology reports have many details that affect how similar diseases look, like which lung lobe is affected or how severe the disease is. The authors created QureRadEmbed, a tool that better understands these fine details by learning from both structured similarity scores and reasoning-based descriptions. This lets it compare radiology reports more accurately and quickly than previous methods. It also helps to find important information in reports even with very few labeled examples.
Open → 2609.33075v1

Artifact removal improves spinal implant x ray measurements accuracy

ARNAI: Artifact Removal Network based on Autoencoding and Inpainting for Robust Spinal Image Segmentation and Measurement

Abstract: Purpose: This study aims to develop an AI framework applicable for postoperative imaging for automated measurement of spinopelvic parameters on radiographs with robustness to the presence of spinal implants. Materials and Methods: We retrospectively reviewed lateral lumbar spine radiographs from two institutions (Internal: January 2017--December 2024; External: October 2021--September 2025). We developed the Restore, Segment, and Measure (RSM) framework, incorporating a novel Artifact Removal Network based on Autoencoding and Inpainting (ARNAI) to mitigate implant-related artifacts in postoperative radiographs. Segmentation and spinopelvic parameter (PT, LL, SS, SCA) measurement performance were assessed using Wilcoxon signed-rank tests and intraclass correlation coefficients. Results: When ARNAI was added to a recent Transformer-based segmentation model, FCBFormer, the mean DSC increased to 0.870 from 0.814, with marked gains at L3--L5 and smaller improvements at L1--L2. On 91 radiographs with implants, the mean L4--L5 segmental Cobb angle error decreased to 4.7 ° from 15.6--16.2 °, an average error reduction of 70%. The ICC for L4--L5 segmental Cobb angle improved to 0.54 (Rater 1) and 0.59 (Rater 2) from 0.18, and ICCs for pelvic tilt, lumbar lordosis, and sacral slope all exceeded 0.70. The improvement in L4--L5 segmental Cobb angle error was statistically significant in the internal implant-containing cohort after correction for multiple comparisons. Conclusion: The proposed RSM framework improved automated spinopelvic parameter measurement in implant-containing postoperative radiographs. By mitigating implant-related artifacts, ARNAI improved segmentation and downstream measurement accuracy, with the greatest benefit observed for L4--L5 segmental Cobb angle estimation, where the mean error was reduced by approximately 70%.

Mon 7 SeptComputer Vision and Pattern RecognitionArtificial Intelligence
The gist
Spinal x rays after surgery can be hard to read because metal implants block details. The authors created an AI system that cleans up these images by digitally removing the implant shadows before measuring the spine angles. Their method led to better spine outlines and much more accurate angle measurements, especially at tricky spine parts with implants. This helps doctors get reliable numbers to assess recovery after spinal surgery.
Open → 2609.07013v1