Papers for

plastic surgeons

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

Optimized shapes and angles reduce skin strain in surgical flaps

Optimized size, shape and orientation of rhombic transposition flaps and excisions by gradient-based methods

Abstract: This work presents a new method for gradient-based optimization of the rhombic transposition flap and the excision it closes, which set the strain of the skin after closure. Previous studies swept at most three parameters. Here, using structural optimization methods, up to eight variables, two flap angles, two cut lengths and the size, shape and position of the rhombic excision, are optimized under up to 32 geometric and stress constraints. The skin is a pre-stretched, incompressible hyperelastic membrane that wrinkles instead of carrying compression. Smoothed level-sets on a fixed grid represent the cuts, and springs between interpolated points the sutures, so designs change without remeshing and the adjoint method gives the sensitivities. The energy the surgery adds to the skin is minimized, and the model reproduces the energies of a published 48-design sweep with a median deviation of 5%. The optimal flap angles, $(-23^\circ, 31^\circ)$, lie outside the swept range and add 63% less energy than the Limberg flap and 15% less than the best swept design. Under unequal in-vivo tension, the optimal flap turns with the direction of the tension. Fitting the excision to the lesion and its margin lowers the energy by a further 35%, and with all eight variables it is 78% below the Limberg flap. This optimum is the same for finer grids, narrower cuts and wider undermining, although wider undermining reduces its gain. Lowering its suture-line stress by 41% costs only 2.3% more energy.

Tue 3 NovComputational Engineering, Finance, and Science
The gist
Surgical flaps are pieces of skin moved to cover wounds, and their size, shape, and angle affect how the skin stretches after surgery. This paper shows a way to use computer calculations to find the best flap design that minimizes skin tension, making surgery less stressful on the skin. The authors used a mathematical model of skin and optimized up to eight design factors at once, finding better flap shapes than previous methods. Their results suggest that adjusting flap parameters to follow skin tension can improve surgery outcomes.
Open → 2611.04563v1

Consistency score measures photographic similarity in surgical photos

Automated Perceptually-Motivated Assessment of Photographic Consistency in Paired Clinical Photographs: Pipeline Development and Internal Evaluation

Abstract: Purpose: Paired pre- and post-operative photographs are the standard unit of evidence for plastic surgical outcomes, yet no objective metric verifies whether two images of the same patient were captured under conditions consistent for comparison. Approach: We developed a perceptually motivated pipeline that analyzes pre/post pairs across thirteen calibrated sub-metrics, partitioned by unsupervised correlation-structure analysis into five data-driven clusters (photometric, texture / sharpness, pose, illumination direction, and pitch), averaged within each cluster and combined across clusters by a weighted sum into a single consistency score. Each sub-metric is calibrated so that its median difference across published within-patient pairs scores 0.5, which is a reference point and carries no pass/fail meaning. The pipeline was calibrated on 134 matched within-patient published pre/post pairs and evaluated against identical-image pairs, synthetic-perturbation pairs, and 134 mismatched cross-publication pairs. Results: The master consistency score S separated matched from mismatched pairs (sensitivity index d' = 2.15, 95% confidence interval (CI) [1.83, 2.55]; area under the receiver operating characteristic curve AUC = 0.928, 95% CI [0.896, 0.959]), closely matching Gaussian-equal-variance predictions. The three head-pose angles did not fall in one cluster: yaw and roll grouped together while pitch separated. Identical pairs scored at ceiling (S = 0.99) and the master score fell monotonically with perturbation magnitude on all five perturbation axes. Conclusions: The score quantifies photographic comparability, not aesthetic or surgical quality, and provides a freely available web tool for auditing the photographic comparability of pre/post pairs, pending validation against expert judgment.

Mon 14 SeptComputer Vision and Pattern Recognition
The gist
Photos taken before and after plastic surgery need to be consistent to fairly compare results, but there's no standard way to check that. The authors created a system that looks at many details like lighting, sharpness, and angle to give a single score showing how similar two photos are. They tested this score on many photo pairs and found it can reliably tell if photos of the same person were taken under similar conditions. This helps ensure fair comparisons without judging the surgery quality itself.
Open → 2609.15144v1