Papers for

medical robotics teams

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

Autonomous laparoscope control improves surgical camera views during key phases

Semantic-Coupled Perception Framework for Autonomous Laparoscope Control

Abstract: In minimally invasive surgery (MIS), maintaining an appropriate field of view (FoV) is essential for surgical safety and efficiency. However, conventional autonomous laparoscope control methods often treat visual tracking and surgical phase recognition independently, limiting robustness under occlusion, entity overlap, and camera motion. This paper proposes a closed-loop autonomous laparoscope control framework that couples real-time surgical phase recognition with camera-motion-compensated visual perception. By exploiting phase-dependent relationships among surgical entities, the framework improves target state estimation under challenging visual conditions, supporting task-aware autonomous FoV control. Experiments on benchmark datasets evaluate the proposed framework in surgical phase recognition and target tracking, including scenarios involving occlusion and entity overlap. Phantom experiments further demonstrate the feasibility of autonomous FoV control, showing improved target visibility and task execution performance compared with fixed-FoV control. These results highlight the potential of incorporating task-level semantics into visual state estimation for autonomous laparoscope guidance.

Sun 25 OctRobotics
The gist
Good camera views during minimally invasive surgery help doctors work safely and efficiently. The authors present a system that links understanding the surgery's current step with smart camera movement, so the camera keeps important things in view even when blocked or overlapping. Tests with data and practice setups show this method helps keep targets visible better than fixed cameras. This could make surgical cameras smarter and more helpful during operations.
Open → 2610.34128v1

MedVLA improves safety and accuracy in medical robot surgery

MedVLA: A Hierarchical Vision-Language-Action Framework for Closed-Loop Precision Medical Robot Manipulation

Abstract: Precision medical robotics demands adaptive decision-making under strict safety, interpretability, and execution constraints. Although recent Vision-Language-Action (VLA) models show strong multimodal reasoning ability, their continuous action generation paradigm is not well suited for precision medical tasks, where reliable closed-loop operation may also depend on non-action system function calls. To address this gap, we propose MedVLA, a hierarchical framework that couples high-level multimodal reasoning with low-level function-constrained execution. We further introduce a scalable multi-agent pipeline to generate skill-oriented chain-of-thought(CoT) data for structured training. Built on different multimodal large-model backbones, MedVLA consistently improves performance after fine-tuning, demonstrating the effectiveness of the proposed framework across model variants. Under identical initial conditions, we perform 100 closed-loop flexible electrode implantation trials. The results show that MedVLA achieves a 95.0\% task success rate, substantially outperforming representative VLA baselines, including OpenVLA (8\%) and $π_0$ (15\%), in accuracy, stability, and safety. These results indicate that structured reasoning with constrained function-level execution is a practical route toward deployable precision medical robotics.

Tue 22 SeptRobotics
The gist
Medical robots need to make smart decisions carefully to safely perform precise tasks. The authors created MedVLA, a system that combines high-level understanding of images and language with strict control over robot actions. MedVLA was tested on a robot implanting electrodes 100 times and succeeded 95% of the time, far better than other methods. This suggests using structured reasoning plus strict action rules can help medical robots work safely and reliably.
Open → 2609.25756v1

Robot mills biological tissue accurately using generic anatomy and active sensing

Autonomous Precision Milling of Biological Structures via Generic Anatomical Priors and Active Boundary Perception

Abstract: Autonomous precision milling of biological structures is challenged by incomplete knowledge of target geometry, local material thickness, and critical internal boundaries. Subject-specific preoperative models can address geometric and thickness variations, but static models cannot determine boundary status encountered during execution, while repeated target-specific imaging limits scalability. This article presents an uncertainty-aware autonomous milling framework that assigns complementary roles to generic anatomical priors and active boundary perception. A generic anatomical prior provides conservative global guidance and is transformed through semantic-guided registration and hybrid vision-force calibration into robot-executable guidance for individual targets. As milling approaches uncertain boundaries, the robot actively probes the remaining structure and uses relative stiffness changes to estimate boundary status and structural detachability. A state-adaptive controller governs transitions between active perception and spatially selective incremental refinement, repeating this cycle until the termination criterion is satisfied. Hierarchical experiments on biological surrogates and in vivo mouse cranial window creation demonstrate accurate anatomical prior transfer, reliable boundary adaptation, and autonomous precision milling of biological structures.

Fri 11 SeptRobotics
The gist
Milling biological tissues precisely is hard because it’s difficult to know the exact shape and material thickness beforehand. The authors present a method where a robot uses general knowledge about anatomy combined with active probing to understand boundaries during the milling process. This lets the robot adjust its actions in real time for safer and more accurate work. They tested this approach on biological models and live mice with promising results.
Open → 2609.12530v1