Papers for
medical imaging platform teams
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Radcarve improves radiology report accuracy by matching anatomy and text
Carving Radiology Reports at Their Evidential Joints: Anatomical Region Sets as Generation Units
Abstract: Organizing radiology reports into independently generated units offers a way to generate fine-grained clinical content and bind it to visual evidence. However, existing methods typically adopt generation-unit structures not directly specified in natural reports or their annotations, introducing additional modeling compromises. We propose RadCarve, which instead defines generation units directly from the anatomical region sets in existing statement-region correspondences, unifying unit formation with visual evidence selection. RadCarve's planner uses composition-specialized query banks to jointly predict unit existence and region composition from the image, iteratively refining both with regional evidence aggregated according to current membership predictions. The generator independently produces each unit's text conditioned on the joint visual evidence of its predicted region set. Compared with strong baselines, RadCarve improves CXRFEScore by 9.4% in unit generation given region sets and achieves 2.4 times the end-to-end binding F1. It also achieves leading report-generation results on Chest ImaGenome and PadChest-GR, using fewer than one-sixth as many parameters as large-scale baselines.
Clinical knowledge guides clearer visual and text alignment for radiology reports
CliQ-RRG: Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report Generation
Abstract: Radiology reports are essential for diagnostic reasoning and patient care, yet their manual preparation is time-consuming and cognitively demanding. Automatic radiology report generation (RRG) offers a scalable alternative, but existing models often produce lengthy, unstructured narratives that overlook diagnostic cues and multi-view information. We present Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report Generation (CliQ-RRG), a unified two-stage framework for interpretable and clinically grounded reporting. In Stage 1, CliQ-RRG employs a Disease-aware Visual-Textual Alignment module that aligns image and text representations using predicted disease embeddings, reinforced by a Prior-Guided Attention Module (PrAM) to capture multi-view dependencies across current and prior scans. In Stage 2, GraphRAG-guided retrieval augments intermediate textual representations with graph-grounded clinical evidence, and a large language model restructures them into concise, interpretable question-answer (QA) pairs with diagnostic summaries. Experiments on two public chest X-ray benchmarks demonstrate that CliQ-RRG consistently outperforms prior methods across both lexical and clinical metrics, generating accurate and clinically coherent QA-style radiology reports. Code is available at: https://github.com/chandravardhan-singh-raghaw/CliQ-RRG.
CineMR improves cardiac MRI analysis by integrating image tools
CineMR: Tool-Integrated Vision-Language Reasoning for Quantitative Cardiac MRI Assessment
Abstract: Cardiovascular magnetic resonance (CMR), including cine imaging, is a reference standard for the noninvasive assessment of cardiac morphology and ventricular function. Cine CMR interpretation integrates qualitative visual assessment with quantitative measurements of ventricular volumes, ejection fraction, myocardial mass, wall thickness, and regional wall motion. Current medical vision-language models (VLMs) cannot reliably derive quantitative measurements from multidimensional cine images without analysis tools. We present CineMR, a tool-augmented VLM that invokes cardiac image-analysis tools and integrates their outputs into interleaved reasoning for quantitative CMR assessment. We also construct a multi-cohort visual question answering benchmark covering quantitative metric extraction, multiclass diagnosis, and differential diagnosis, together with tools for segmentation, phase selection, volumetry, morphometry, and regional wall motion analysis. CineMR is trained with supervised fine-tuning (SFT) on tool-interaction traces followed by Group Relative Policy Optimization (GRPO) with conditional tool-use rewards. On the multi-cohort cine CMR benchmark, CineMR achieves 35.9% pass@1 and 58.9% pass@4, compared with 1.5% pass@1 for the Qwen3-VL-8B backbone and 0.0% and 7.0% pass@1 for LLaVA-Med v1.5 and MedGemma-4B, respectively. Correct tool invocation reaches 99.8% after GRPO, up from 78.9% after SFT. Live tool outputs improve ventricular measurement accuracy by 20.4--23.7% over direct model predictions, and removing all tools reduces pass@1 from 35.9% to 27.9%. These results highlight the importance of reliable tool use for quantitative cine CMR reasoning and support CineMR as a promising approach for assistive cardiac image assessment. Code, benchmark resources, and model weights are available at https://github.com/AI-MIND-Lab/CineMR.
AgenTeeth reduces errors in dental X-ray language models
AgenTeeth: A Model-Agnostic Framework for Suppressing Hallucination in Frozen Vision-Language Models on Dental X-Rays via Tool Evidence Injection
Abstract: Vision-language models (VLMs) remain largely unreliable on panoramic dental radiographs and can rely on learned anatomical priors rather than evidence in the image. This is particularly problematic for tooth localization and spatial reasoning, and fine-tuned dental VLMs can retain the same spatial biases. We present AgenTeeth, a model-agnostic, tool-augmented framework that grounds frozen VLMs using seven specialized dental vision experts. A question-aware orchestrator selects the relevant tools, whose detections are mapped to FDI tooth numbers or anatomical regions and returned as structured findings together with annotated image overlays. A fresh synthesis call then answers the question using this evidence, without fine-tuning the underlying VLM. On MMOral-OPG-Bench, AgenTeeth improves four backbone VLMs by 12.9-23.0 percentage points over their baselines. Our strongest configuration reaches 65.66% on open-ended VQA, compared with 45.35% for OralGPT-Plus. The advantage also holds at matched scale: a frozen Qwen2.5-VL-7B-Instruct with AgenTeeth reaches 48.11%, exceeding OralGPT-Plus built on the same backbone after supervised fine-tuning and reinforcement learning for tool use. We release the framework, all seven expert models, and a dentist-annotated dataset for alveolar bone-loss detection in panoramic radiographs.
NnU-Net shows varied accuracy on different brain tumor types
Assessing nnU-Net Generalization across Brain Tumor Populations in BraTS-GoAT 2026
Abstract: BraTS-GoAT evaluates tumor segmentation across heterogeneous populations. We trained a conventional 3D nnU-Net on 1,351 labeled cases using five-fold cross-validation and 1,000 epochs per fold. The final predictor averaged all folds and applied test-time mirroring. On pooled official validation, global DSC values were 0.7805, 0.8288, and 0.8854 for enhancing tumor (ET), tumor core (TC), and whole tumor (WT). Under matched fold-0 inference, mean regional Dice decreased from 0.9058 on source out-of-fold (OOF) cases to 0.8310 on pooled validation (difference--0.0747). Mirroring gave small single-fold gains but no clear ensemble benefit; a residual-encoder alternative reached 0.8282 mean Dice. In labeled OOF predictions, failure cases had substantially smaller reference ET volumes; after adjustment for ET and WT volume, lower Dice remained associated with more disconnected ET components and a smaller fraction of ET contained in the largest component.