Papers for
industrial inspection engineers
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Training data quality matters more than loss type in image denoising
Noise2Noise Revisited: Training Pair Distributions Dominate Loss Choice in Self-Supervised Denoising
Abstract: Noise2Noise (N2N) trains denoisers on pairs of independently corrupted observations, eliminating clean references. We stress-test two natural conjectures about why the L1 loss outperforms L2 here. First, the hypothesis that the L1 loss confers robustness via parameter sparsity confuses the loss with Lasso regularization: an explicit Lasso penalty produces the predicted sparsity yet fails to reproduce L1's cross-noise behavior, while L1- and L2-trained weight distributions are indistinguishable. Second, the population optima of the two losses coincide exactly for symmetric signal posteriors and nearly so for concentrated ones. Measured differences are therefore dominated by optimization dynamics (bounded-influence gradients), which we probe with gradient statistics and contaminated-target training. On Kodak24 with five synthetic noise families, the L1 loss holds a statistically significant edge over L2, below 1 dB PSNR, holding across three seeds on 13 of the 14 noise columns. On real camera noise the loss is not the decisive variable in distribution: on official SIDD validation blocks, synthetic-Gaussian-trained N2N models gain only 0.8 to 3.7 dB over the noisy input regardless of loss, while retraining on SIDD's own noisy pairs, never reading ground truth, gains 9.4 to 11.0 dB, far ahead of BM3D. All metrics are on raw network outputs, and the study makes no leaderboard claim. The training pair distribution, not the loss, carries the inductive bias. That design rule applies wherever clean references are unobtainable, from microscopy to industrial inspection sensors.
Quantum walk simulates X-ray scattering for better imaging
QCxSimulation: Scatter-Aware X-Ray Projection Radiography via Discrete-Time Quantum Walks
Abstract: X-ray projection radiography is a non-invasive imaging technique used in medical diagnostics and industrial inspection. The simulation of X-ray projections is commonly used to optimise acquisition protocols and improve image quality before performing costly scans. Classical photon transport simulations that include realistic X-ray scattering physics are computationally expensive because they require the sampling of a large number of distinct scattering paths. This limits the practical exploration of parameter spaces such as beam energy. Quantum computing offers the potential to solve high-dimensional problems faster by making use of quantum properties such as superposition. This work introduces a discrete-time quantum walk algorithm that simulates the transport of X-ray photons through heterogeneous volumes. It approximates the physics of X-ray projection radiography, including processes such as photoelectric absorption and higher-order scattering, including Compton and Rayleigh scattering. The quantum walk encodes all admissible photon paths into a single quantum state, enabling all scattering histories to be propagated simultaneously via the superposition principle. This quantum state representation enables flexible readout of various imaging modalities, including the primary, i.e., unscattered, image, or images exclusively containing Rayleigh and Compton scattering of specified orders. A quantitative comparison with classically computed reference simulations shows that the proposed quantum walk accurately reproduces radiographic projections, given the limitations of the underlying physical model. These results indicate that quantum circuits for X-ray transport can produce accurate radiographic images and imply that, as quantum hardware scales up, these algorithms could outperform classical Monte Carlo-based approaches in large-scale, scatter-aware virtual imaging studies.