Papers for

hospital radiology teams

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

Lungmend corrects lung masks on severe tuberculosis ct scans

LungMend: A Healthy-Only Latent Diffusion Shape Prior for Lung Mask Correction in Severe Tuberculosis CT

Abstract: Lung segmentation models such as R231 are widely used, but they fail on severe tuberculosis (TB) CT: cavities and consolidations look like non-lung tissue and are left out of the mask. We present LungMend, a post-processing model that corrects such masks using only healthy anatomy. A latent diffusion model, trained on healthy lungs with synthetically corrupted masks, learns to recover the complete lung from the faulty mask and the bone anatomy, without any pathological data or CT intensities. LungMend recovers cavities and consolidations that R231 misses and improves accuracy on expert-annotated slices. Code: https://github.com/noureddinekhiati/LungMend

Wed 4 NovComputer Vision and Pattern Recognition
The gist
Lung scans of people with serious tuberculosis can be hard to analyze because the disease changes the lung’s shape in ways that confuse computers. The authors created LungMend, a tool that fixes these mistakes by learning what healthy lungs look like and then guessing the complete lung shape, even when parts are damaged or missing. Unlike previous methods, LungMend does this without needing examples of diseased lungs or the original scan details. This helps doctors see the full lung area more accurately in severe cases.
Open → 2611.06556v1

BrainGFM improves brain image tasks with generative AI model

A generative foundation model for computational brain imaging

Abstract: Computational brain imaging is constrained by a mismatch between increasingly diverse tasks and scarce, heterogeneous clinical data. Although existing brain foundation models transfer pretrained representations, their knowledge remains entangled within model-specific features and fixed architectures. This paper proposes BrainGFM, a generative foundation model that extends knowledge transfer beyond representation reuse through a reusable and reconfigurable brain-imaging prior. By pretraining on a corpus of about 1.3 million MRI and CT slices, BrainGFM supported task-aligned data synthesis for low-data predictive learning and task-adapted post-training for image reconstruction. Across 48 downstream tasks, BrainGFM improved segmentation and classification under limited supervision and achieved high-fidelity image enhancement across heterogeneous imaging conditions. Multicenter clinical validation involving 4,796 stroke patients across two internal and four external centers demonstrated its applicability to three clinically relevant tasks around stroke cohorts. Blinded reader assessments showed that BrainGFM-generated FLAIR images approached acquired FLAIR in overall diagnostic quality. In a human-AI collaboration study, BrainGFM assistance yielded a 14% relative improvement in mean radiologist stroke-subtyping accuracy. These findings support generative priors as a reusable foundation for heterogeneous computational brain-imaging applications.

Fri 30 OctArtificial Intelligence
The gist
Brain imaging techniques like MRI and CT scans often face challenges because there isn’t enough consistent patient data for many tasks. The authors designed BrainGFM, a new AI model trained on over a million brain scan slices that can generate realistic and useful brain images. This model helps improve the accuracy of brain scan analysis and image quality, especially when there isn’t much data to work with. In tests involving thousands of stroke patients, BrainGFM's generated images were nearly as good as real scans and helped doctors classify stroke types better.
Open → 2611.00265v1

New method completes missing brain tumor MRI sequences preserving 3D details

MOSAIC-Flow: Orthogonal-Axis and Status-Conditioned Fusion for Missing-Sequence Completion in Brain Tumor MRI

Abstract: Missing-sequence completion is important for comprehensive brain tumor characterization, but cross-modal fusion can obscure sequence-specific contrast and lose fine-grained three-dimensional tumor detail. To address this challenge, we introduce Modality-aware Orthogonal-axis Status-conditioned Attentive Integration for Completion (MOSAIC-Flow), a unified framework for missing-sequence completion that learns a target-conditioned velocity field while keeping the seven acquired volumes fixed throughout the transport. Specifically, modality-aware stems independently encode each sequence, and orthogonal-axis refinement captures axial, coronal, and sagittal dependencies while retaining the three-dimensional representation. Status-conditioned prototype fusion uses compact modality and availability tokens to route and modulate pooled queries from the fused visual representation, enabling target-adaptive conditioning without dense voxel-to-voxel attention. A conditional flow matching objective transports target-channel noise toward the single missing sequence, while four Heun trajectories are averaged to produce the completion. Evaluation across structural, diffusion, and contrast-enhanced MRI in UCSF-PDGM demonstrates consistent whole-brain and tumor-region fidelity across all eight single-target completion tasks, with the strongest performance on structural sequences. Code is available at https://github.com/CUHK-AIM-Group/MOSAIC-FLOW.

Thu 29 OctComputer Vision and Pattern Recognition
The gist
MRI scans of brain tumors often have missing image types, which makes it hard to fully understand the tumor. The authors developed a new method called MOSAIC-Flow that can fill in these missing images while keeping fine 3D details intact. Their approach processes each MRI type separately, looks along three different body directions, and adapts based on which images are available. Tested on a dataset of brain tumor MRIs, MOSAIC-Flow showed consistent quality in completing different missing image types, especially structural MRI scans.
Open → 2610.39534v1

Breast ultrasound diagnosis improved with concept-informed AI system

A Concept-informed Interpretable Artificial Intelligence Framework for Breast Ultrasound Diagnosis

Abstract: Most existing artificial intelligence systems for breast ultrasound rely primarily on image-driven prediction, with limited incorporation of the knowledge from the Breast Imaging Reporting and Data System (BI-RADS) and the intermediate assessment processes underlying radiologists' workflow, thereby constraining their interpretability and alignment with clinical practice. We curated, to our knowledge, the largest multicenter collection of breast ultrasound images paired with structured BI-RADS descriptors, comprising 9,941 patients across 20 independent datasets. Across 14 testing datasets, IBUS demonstrated consistent generalization performance across different clinical centers and imaging conditions. Incorporating BI-RADS descriptors enabled fine-grained risk stratification, while cross-checking predicted BI-RADS grades against malignancy probabilities identified internally discordant predictions that may warrant additional clinical review. In a reader study involving eight radiologists, IBUS assistance increased diagnostic sensitivity among both junior and senior readers, with the potential of guiding radiologists to make targeted revision in risk stratification. Overall, IBUS exhibits its potential as a second-stage decision-support system that complements radiologists by providing additional risk estimates and interpretable evidence for diagnostically challenging cases. The demo video of IBUS platform is publicly available at https://github.com/zsz1997/IBUS.

Mon 12 OctComputer Vision and Pattern Recognition
The gist
Breast ultrasound scans are important for spotting cancer, but computers often only look at images without understanding medical concepts doctors use. The authors created a large collection of breast ultrasound images with detailed medical notes and built an AI system that mimics how doctors think by using this knowledge. This helps the AI explain its decisions better, catch risky cases more accurately, and assist doctors in making better diagnoses. Tests show the AI works well across different hospitals and helps both new and experienced doctors improve sensitivity in finding cancer.
Open → 2610.16128v1

Adaptive reasoning improves medical image diagnosis for inflammatory bowel disease

ARISE: Adaptive Agentic Reasoning with Image-grounded Self-Evaluation for Interpretable IBD Assessment

Abstract: Inflammatory bowel disease (IBD) requires frequent imaging-based assessment, yet interpretation of modalities such as wireless capsule endoscopy (WCE) and intestinal ultrasound remains heavily dependent on specialist expertise. Vision-Language Models (VLMs) demonstrate significant potential in multimodal medical image analysis, but their clinical adoption is hindered by their insufficient domain-specific reasoning, susceptibility to hallucination, scarcity of high quality training data in fine-grained diagnostics and limited interpretability. We introduce ARISE (Adaptive Agentic Reasoning with Image-grounded Self-Evaluation), an autonomous planning framework that models few-shot medical image understanding as a sequential agentic workflow. ARISE structures agent execution into a transparent 5-stage workflow: hypothesis generation, image-grounded evidence summarization, evidence-conditioned refinement, symbolic verification, and final diagnosis. We apply ARISE to IBD assessment across two independent patient cohorts: wireless capsule endoscopy (WCE) images for Crohn's disease and B-mode ultrasound data for ulcerative colitis. ARISE consistently improves diagnostic performance over baseline VLMs while exposing where reasoning succeeds or fails, providing a more interpretable basis for clinical decision support and realistic deployment.

Sat 3 OctComputer Vision and Pattern RecognitionArtificial Intelligence
The gist
Inflammatory bowel disease is a condition requiring frequent image tests that can be hard to interpret without expert doctors. The authors created a new step-by-step approach called ARISE that helps computer models better understand medical images by thinking through the problem in stages and checking their own reasoning. They tested ARISE on two types of images from patients and found it made more accurate and understandable diagnoses than existing methods. This approach could help doctors make better decisions by showing how the computer reached its conclusions.
Open → 2610.04777v1

RSNA releases large dataset to help detect brain aneurysms with AI

The RSNA Intracranial Aneurysm (RSNA-ICA) Dataset

Abstract: Intracranial aneurysm rupture is associated with substantial morbidity and mortality, yet aneurysm detection remains challenging, particularly for small lesions and on routine non-angiographic imaging examinations. To support the development and evaluation of artificial intelligence (AI) algorithms for intracranial aneurysm detection and localization, the Radiological Society of North America (RSNA), in collaboration with the American Society of Neuroradiology (ASNR), the Society of Neurointerventional Surgery (SNIS), and the European Society of Neuroradiology (ESNR), curated the RSNA Intracranial Aneurysm (RSNA-ICA) Dataset. Developed for the 2025 RSNA Intracranial Aneurysm Detection Challenge, RSNA-ICA is a large, publicly available, expert-annotated dataset comprising 7202 CTA, MRA, and MRI series from 4278 adult patients collected across 21 institutions in 12 countries spanning five continents. The dataset includes 2566 CTA, 2166 MRA, and 2470 MRI series from patients with and without intracranial saccular aneurysms, providing substantial geographic and imaging diversity. Expert annotations indicate both aneurysm presence and location, and 178 series additionally include three-dimensional segmentations of challenge-defined vascular locations. RSNA-ICA was used to develop and evaluate algorithms in the 2025 RSNA Intracranial Aneurysm Detection Challenge. Of the 7202 image series, 5041 are publicly available through MIRA (https://mira.rsna.org/dataset/7), while the remainder were used for challenge public and private test sets. The dataset is freely available to the research community for noncommercial use and provides a comprehensive resource for advancing AI-based aneurysm detection across both angiographic and routine neuroimaging examinations.

Thu 1 OctComputer Vision and Pattern Recognition
The gist
Detecting brain aneurysms, especially small ones, is hard but important to prevent serious health problems. To help computers learn to spot these aneurysms in scans, the authors created a big, carefully labeled collection of brain images from many hospitals worldwide. This public dataset contains different types of scans, with expert notes on where aneurysms are found. It aims to boost AI tools that assist doctors in finding aneurysms more accurately on routine brain imaging.
Open → 2610.01135v1

Ai models show varied accuracy for detecting pulmonary embolism in real hospitals

Multi-Site Real-World Performance of Commercial AI for Pulmonary and Incidental Pulmonary Embolism Detection

Abstract: Pulmonary embolism (PE) is a leading cause of cardiovascular mortality, yet the real-world performance of FDA-cleared AI detection models remains incompletely characterized. We retrospectively evaluated two FDA-cleared AI algorithms from a single commercial platform (Aidoc Medical BriefCase), one for PE triage on dedicated CT pulmonary angiography (CTPA; n = 30,678) and one for incidental PE (iPE) detection on routine contrast-enhanced CTs (n = 37,191), across a 17-facility academic health system. Reference-standard labels were extracted from radiology reports using a validated LLM pipeline (97% accuracy, kappa = 0.94). The PE model achieved 86.8% sensitivity and 99.1% specificity, with sensitivity declining from 99.3% for saddle emboli to 72.9% for subsegmental PE, and from 89.7% for acute to 65.3% for non-acute PE. The iPE model achieved 73.5% sensitivity and 99.8% specificity. Both models demonstrated lower sensitivity than FDA-clearance benchmarks while exceeding cleared specificity, with diminishing performance for peripheral and non-acute emboli mirroring known human reader limitations and underscoring the need for standardized post-market surveillance of AI-enabled medical devices.

Tue 29 SeptComputer Vision and Pattern RecognitionArtificial Intelligence
The gist
Pulmonary embolism is a serious condition causing blood clots in the lungs, but detecting it accurately can be hard. The authors looked at two AI programs used in hospitals to find these clots in lung scans. They found the AI was very good at spotting large, recent clots but often missed smaller or older ones. This means current AI tools work well in some cases but still need improvement and careful monitoring when used in real-world healthcare settings.
Open → 2609.37750v1

Radiology report generation adapts to varying clinical data availability

PACER: Progressive Availability-Conditioned Evidence Routing for Radiology Report Generation under Incomplete Clinical Context

Abstract: Radiology report generation (RRG) increasingly incorporates heterogeneous clinical evidence, such as multi-view radiographs and previous reports, whose availability varies across examinations. However, accommodating different input combinations does not ensure effective evidence use: generated reports may still omit or inaccurately describe clinically relevant findings. To address this problem, we propose PACER, a Progressive Availability-Conditioned Evidence Routing framework for structured incomplete-context RRG that follows a Refine-Calibrate-Commit pipeline. It first refines observed visual representations through endpoint-preserving patchwise routing across frozen encoder depths, incorporating complementary cues while retaining the pretrained terminal representation. It then calibrates the language-model prefix according to the observed evidence and availability state, adapting the shared generator's conditioning as the available source set changes. Finally, it generates polarity-structured clinical commitments before the report in the same autoregressive trajectory, providing structured clinical context for subsequent generation. Experiments demonstrate state-of-the-art clinical efficacy across all four MIMIC-RG4 settings and strong MIMIC-CXR performance, while maintaining competitive language-generation quality.

Mon 28 SeptComputer Vision and Pattern Recognition
The gist
Radiology reports often rely on different kinds of medical information, but not all information is always available for each patient. This paper presents a new method called PACER that progressively uses whatever evidence is present to make more accurate and reliable reports. The system refines image data, adjusts text generation based on what clues it has, and creates structured clinical statements to guide the report. This approach improves the clinical accuracy of reports even when some patient information is missing.
Open → 2609.34487v1