Papers for

hospital diabetes care teams

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

DiabAgent advances glucose control with adaptive AI decision tools

DiabAgent: Toward Agentic Physiological Control

Abstract: As pretraining scales, medical language models have advanced rapidly in clinical question answering. Their ability to achieve effective physiological control through sustained intervention still lacks systematic quantitative evaluation. Type 1 diabetes provides a concrete setting: impaired insulin secretion creates dependence on exogenous insulin, with dosing continually adjusted using information about meals, exercise, illness, and glucose measurements. We introduce DiabAgent, a research suite for agentic physiological control comprising the Agentic Physiological Control (APC) framework, the DiabetSim simulator, and the SweetBench benchmark. APC controls glucose through medical-device tools, using ongoing observations to infer individual states, accumulate personal experience, and choose treatment actions. We build DiabetSim to simulate different patients, events, and device conditions for scalable virtual testing and training. Using DiabetSim, we construct SweetBench by instantiating 32 scenario designs as 212 glucose-control tasks. With Claude Opus 5.5 and a fixed decision interval of one hour, APC achieves a COGI of 73.5, compared with 71.2 for the open-source closed-loop baseline OpenAPS. Ablations further show that individual adaptation and contextual information improve glucose control. Combining high-frequency rule-based control with lower-frequency agent decisions shows potential for balancing control performance and computational cost. Our work provides a framework, simulator, and evaluation foundation for agents to participate in human physiological control.

Mon 2 NovArtificial IntelligenceComputation and Language
The gist
Managing blood sugar in type 1 diabetes requires carefully timed insulin doses based on many factors like meals and exercise. The paper presents DiabAgent, a new system that uses artificial intelligence to make smarter insulin dosing decisions by learning from continuous data about an individual’s condition. It includes a simulator to test how well different approaches work and shows that combining AI decision-making with rule-based control improves managing glucose levels. This work provides a way to build and test AI agents that could help control human physiology more effectively.
Open → 2611.03601v1

Digital-twin models compared for reliable short-term blood sugar risk prediction

Reliability-Aware Short-Term Glycemic Risk Prediction Using an Anchor-Based Comparative Framework of Sequence, Multimodal, and State-Updating Digital-Twin Models

Abstract: Anticipating short-term hypoglycemic and hyperglycemic risk is essential for proactive diabetes management. However, existing machine learning approaches often use inconsistent evaluation protocols and emphasize predictive performance over reliability. This study introduces an anchor-based benchmarking framework integrating longitudinal glucose sequences and multimodal patient information. Using the T1DiabetesGranada dataset, 5,503,441 standardized prediction anchors were constructed from 736 individuals with type 1 diabetes to evaluate hypoglycemia and hyperglycemia prediction at 30-, 60-, and 120-minute horizons. Three neural architectures, a Hybrid LSTM-Transformer, a Multimodal Digital Twin, and a State-Updating Digital Twin with gap-aware longitudinal state progression, were compared under identical patient-level validation protocols. Beyond predictive performance, the evaluation examined calibration, classification thresholds, explanation reliability, cross-model disagreement, and robustness to controlled perturbations. No statistically significant predictive differences were observed after Holm correction, although the models exhibited complementary reliability characteristics. The Multimodal Digital Twin achieved the lowest mean Brier score, while the State-Updating Digital Twin demonstrated the lowest mean expected calibration error (ECE-10). The Hybrid LSTM-Transformer showed strong explanation faithfulness and stability under its temporal attribution protocol. These findings highlight the importance of evaluating digital-twin models beyond predictive accuracy and emphasize the need for reliability assessment and external validation before clinical deployment.

Mon 26 OctMachine LearningArtificial Intelligence
The gist
Predicting low or high blood sugar shortly ahead is important for people with type 1 diabetes to avoid health problems. The authors developed a way to fairly compare different computer models that use daily blood sugar data and other personal info. They found no big differences in accuracy but saw that each model was better at certain reliability aspects like confidence and explanations. This shows it’s important to check these models carefully before using them in medical settings.
Open → 2610.36363v1