Machine learning fault detectors show more false alarms across relay locations

Characterizing Cross-Relay Generalization Failure in Machine Learning-Based Power System Protection

Abstract: Machine learning-based fault detectors are often evaluated at the relay locations used for training, although local voltage and current measurements vary across power networks. This work investigates cross-relay generalization for binary detection of faults anywhere in the network using local measurements, rather than line-selective tripping. Using 50 ms windows from a simulated 110 kV transmission network, we evaluate a multilayer perceptron across all 64 source target combinations of eight relays and five random seeds. A shared simulation-level split and source-only threshold selection provide a controlled held-out evaluation without target-specific calibration. Despite nearly unchanged mean F1-scores (0.730 within-relay versus 0.734 cross-relay), the mean false-positive rate (FPR) increases from 0.088 to 0.341, while the mean false-negative rate decreases from 0.399 to 0.318. The change is strongly directional: models trained at Bus 2 relays yield a mean FPR of 0.670 at Bus 1 and Bus 3 relays, compared with 0.096 for cross-relay transfers within the same bus group. Linear probing indicates that learned representations retain coarse bus-group information, while exploratory class-conditional latent distribution analysis shows no consistent monotonic association with transfer errors. These findings demonstrate that aggregate metrics can conceal location-structured changes in false-alarm behavior, highlighting the importance of evaluating error types separately when assessing cross-relay generalization.

Tue 20 OctMachine Learning
The gist
Machine learning models used to detect electrical faults often train on data from specific locations in a power grid, but measurements vary across different spots. The authors studied how well a fault detector trained on one relay’s data performs when applied to others. They found that overall accuracy looks stable, but false alarms increase a lot when applying the model to different relay locations. This means measure-specific differences can hide problems that appear when moving machine learning models across the network.
Open → 2610.28348v1

Offline rl selects faulted lines accurately in simulated power grids

Offline Reinforcement Learning for Distribution-Grid Protection

Abstract: Data-driven protection may complement conventional relays in distribution grids whose operating conditions vary with distributed generation, switching events, and changing short-circuit levels. We study line-selective tripping from static trajectories of a realistically simulated CIGRE medium-voltage network using offline reinforcement learning. A convolutional Q-network receives causal voltage-current phasor and apparent-impedance features, optionally together with raw waveforms, and is trained with conservative Q-learning (CQL). A controlled sensitivity study evaluates two observation windows, reward variants, and three CQL weights under a common split and training protocol; one exploratory post-hoc run additionally increases the discount factor from $γ$=0.95 to 0.99. On 225 held-out episodes, the best per-timestep result is obtained with combined input and CQL weight $α$=0.9, reaching precision 0.9993, recall 0.9496, and F1-score 0.9738. Because dense per-timestep scores do not encode the terminal semantics of relay operation, we also evaluate the first non-wait action in each episode. The default combined-input agent selects the correct line-trip action first in 98.13% of 214 fault episodes, but trips in 72.73% of the 11 non-fault episodes. In the post-hoc run, the corresponding rates are 98.60% and 54.55%, respectively. The results show that dense predictive performance and terminal protection behavior can lead to different model rankings. Offline CQL therefore demonstrates strong faulted-line selection on the simulated fault episodes, while the static trajectories, small non-fault set, and single-seed post-hoc design preclude conclusions about practical relay security or deployment readiness.

Mon 21 SeptMachine Learning
The gist
Protecting electrical lines in power distribution networks is tricky because conditions change a lot. The authors tested a method called offline reinforcement learning to identify and isolate faulty lines using simulated data. Their system analyzes electrical signals to decide which line to trip, achieving high accuracy in test scenarios. However, the study was done under limited conditions and more work is needed to confirm how well this would work in the real world.
Open → 2609.24703v1