Papers for

clinical radiology departments

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

Pooled transfer learning improves brain vessel MRI image resolution

Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer Learning

Abstract: We evaluated synthetic pretraining and multi-cohort transfer learning for deep learning-based super-resolution of intracranial 4D Flow MRI across heterogeneous neurologic cohorts. This mixed prospective-retrospective study analyzed 18 participants (12 healthy participants, 3 with moyamoya disease, and 3 with multiple sclerosis) with paired 1.2-mm and 0.6-mm 4D Flow MRI scans. A convolutional neural network pretrained on synthetic cerebrovascular data was fine-tuned using cohort-specific or pooled multi-cohort in vivo data. High-resolution-derived inputs enabled voxel-wise evaluation; native standard-resolution scans were used for angiographic and hemodynamic analyses. Synthetic pretraining reduced mean artery-wise velocity-normalized root mean square error (vNRMSE) versus interpolation (0.147 vs 0.166). Pooled transfer learning yielded the lowest mean vNRMSE (0.119 vs 0.127 for cohort-specific models and 0.147 for synthetic pretraining), with narrower 95% limits-of-agreement widths than synthetic pretraining across all test cases (0.109-0.222 vs 0.154-0.278 m/s). Super-resolved phase-contrast angiography achieved higher precision-recall area under the curve than native standard-resolution imaging in all cohorts (0.848-0.896 vs 0.486-0.805). These results indicate that pooled transfer learning improves cross-cohort reconstruction agreement and that super-resolution can improve vessel depiction, supporting further multi-center validation for cerebrovascular imaging.

Mon 26 OctComputer Vision and Pattern Recognition
The gist
High-resolution MRI scans of brain blood vessels can help doctors see details better but are hard to get. The authors tested a computer program that boosts lower-quality MRI images to high resolution using smart learning from different patient groups. They found training the program on combined data from multiple groups made it more accurate than training on single groups or synthetic data alone. This improved detail helps show blood vessels more clearly, which could assist doctors in diagnosing brain diseases. The results suggest this approach should be tested more widely before clinical use.
Open → 2610.35396v1

A3PreCore improves brain mask alignment for native FLAIR MRI scans

A$^3$PreCore: Robust Rigid Registration for Native FLAIR-Space Brain-Mask Transfer

Abstract: Reliable brain-mask transfer into native fluid-attenuated inversion recovery (FLAIR) space can fail when T1-to-FLAIR rigid registration is unstable. We developed A$^3$PreCore, a six-degree-of-freedom rigid-registration strategy that aligns the full bias-corrected T1-weighted image to native FLAIR using normalized mutual information while preserving the established T1-space anatomical mask. We also introduced extended quantitative quality control (E-QC), which characterizes mask extent, field-of-view-relative position, FLAIR intensity support, boundary support, inferior morphology, and pairwise geometric disagreement. In 78 participants with paired T1-weighted and FLAIR imaging, A$^3$PreCore was compared with fsl_anat and the Brain Extraction Tool (BET). Gross rigid-body misregistration occurred in 21/78 fsl_anat outputs (26.9%) and 0/78 A$^3$PreCore outputs (exact two-sided McNemar p=9.54 x 10^-7). Among 57 participants without gross fsl_anat misregistration, A$^3$PreCore preserved close agreement (median Dice=0.993; median paired Delta NMI=-0.00007, p=0.429). A$^3$PreCore remained broadly concordant with BET (median Dice=0.955), with less inferior and extracranial extension in representative comparisons. Method-blinded neuroscientists ranked A$^3$PreCore first in 35/40 participants (87.5%). E-QC additionally exposed severe orientation-related disagreement not evident from global descriptors or centroid displacement alone. These findings support A$^3$PreCore as a robust native-FLAIR brain-mask transfer strategy and E-QC as a complementary framework for multidimensional mask characterization and participant-specific geometric quality control.

Wed 14 OctComputer Vision and Pattern Recognition
The gist
Getting brain images properly lined up can be tricky when using different types of MRI scans. The authors created a new way, called A3PreCore, to better align brain masks between two common types of scans, making the process more reliable and accurate. They also developed a system to check how good the alignment is, catching problems others might miss. Testing on 78 people showed that their method worked better than existing tools and was preferred by experts.
Open → 2610.20561v1

VoxelSynth3D reduces metal artifacts in musculoskeletal CT scans

VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC-Metal Benchmark

Abstract: Metal artifacts in postoperative musculoskeletal CT obscure bone-implant and adjacent soft-tissue interfaces. Many metal artifact reduction (MAR) methods require unavailable raw projections or learned models that may shift across scanners and implants. We present VoxelSynth3D, a training-free 3D image-domain framework for reconstructed CT. The framework combines support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. Detected implant voxels are preserved in the output, while correction targets metal-induced artifacts in the surrounding tissue. We also construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource, from no-metal CTPelvic1K volumes with clean targets, metal/artifact masks, fixed seeds, and patient-level splits; 75 unpaired real metal cases receive qualitative/no-reference evaluation only. The operating point was fixed in a near-flat validation basin. With exact-mask oracle localization, all methods share a metal-excluded tissue ROI. On 40 held-out cases, VoxelSynth3D reduced RMSE from 801.48 to 786.18 HU (paired gain 15.30 HU, 95% CI 11.68-19.23), improving every case and exceeding the evaluated 3D Gaussian smoother by 13.58 HU. Clean-edge agreement decreased next to metal but exceeded input beyond 5 mm. Thus, VoxelSynth3D provides case-consistent within-distribution tissue-error reduction with a localized structural tradeoff. Spacing-aware sensitivity retained aggregate broad-region improvement and identified near-metal calibration as a target.

Thu 1 OctComputer Vision and Pattern Recognition
The gist
Metal objects inside the body, like implants, can cause blurry or distorted areas in CT images, making it hard to see bones and soft tissues clearly. The authors propose VoxelSynth3D, a method that improves CT images by fixing these blurry areas without needing extra data or training. They also created a synthetic dataset to test how well different methods work at removing these metal artifacts. Their approach gently improves image quality near the metal while keeping important implant details intact.
Open → 2610.01512v1