Papers for
clinical pathology labs
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
PathXAI improves pathology reports using tissue segmentation and AI
PathXAI: Evidence-guided structured pathology reporting by transferable tissue segmentation
Abstract: Pathology reporting requires translating tissue observations across regions and slides into specific diagnoses and supporting morphological descriptions. However, the use of explicit tissue-composition measurements to guide H&E-based report generation remains underexplored. Thus, we developed PathXAI, which combines segmentation-derived tissue information with H&E images and optional domain knowledge to guide diagnostic reasoning, targeted reinspection and structured report writing. Its segmentation component exceeded baselines in mean Dice on internal and external tests. In automated report evaluation on 1,200 public and 151 private cases, PathXAI achieved higher agreement with reference diagnoses and documented morphology than the H&E-based comparators. On the public evaluation cohort, PathXAI-Report exceeded Qwen + H&E in cancer family match rate by 4.4 percentage points and in finding F1 by 5.7 percentage points. PathXAI generates evidence-linked reports with a self-hosted pretrained vision-language model, without updating its weights.
Pathology images enhanced with pseudo 3d views from single slides
PathoS2VD: From 2D Histopathology to Pseudo Z-Stack Representations
Abstract: For decades, diagnostic pathology has relied on thin two-dimensional (2D) tissue sections, despite biological tissues exhibiting inherently three-dimensional (3D) morphological organization. Because a single section captures only one focal plane, important morphological cues along the z-axis are inevitably discarded, limiting tissue representation for both human interpretation and computational analysis. In this work, we propose a generative framework that learns z-axis morphological priors from pathology z-stack data, offering a cost-effective alternative to dedicated volumetric imaging, and transfers this knowledge to conventional single-plane histopathology. Specifically, an image-to-video (I2V) latent diffusion model (LDM) is trained to synthesize a pseudo z-stack from a single 2D image, capturing plausible morphological variations across adjacent focal planes rather than reconstructing physical tissue volumes. To enable deployment on large-scale clinical datasets without native z-stack acquisition, we further introduce a prior-preserving mixture fine-tuning strategy that adapts the model to new domains while retaining the learned z-axis morphological prior. Extensive experiments demonstrate that the synthesized pseudo z-stacks exhibit realistic cross-plane morphological continuity and consistently improve downstream prostate cancer classification compared with conventional 2D representations. Our results suggest that learning transferable z-axis priors from limited z-stack data provides a practical way to enrich routine pathology images with complementary morphological information. Code: https://github.com/QuIIL/PathoS2VD.
Kidney transplant inflammation scoring improved by 3D volumetric analysis
3D Banff Glomerulitis Scoring for Kidney Transplant Pathology: Feasibility Study for Volumetric Quantification
Abstract: Quantifying glomerular inflammation in kidney-transplant biopsies is traditionally performed on single whole-slide sections using the Banff "most-severe section" rule, despite the inherently three-dimensional nature of lesion distribution. This 2D based assessment might lead to instability when inflammation varies across slices. This paper reports a feasibility study examining the technical feasibility and clinical relevance of extending Banff scoring into three dimensions. To this end, we propose a 3D Banff lesion-scoring framework that aligns serial sections, reconstructs glomerular identities across depth, and integrates inflammatory-cell counts in 3D under three scoring strategies: Compatible, Volumetric, and Deduplicated Volumetric. In the experiments, glomerulitis (g-scores) was used as an example Banff metric and applied to multi-section renal allograft biopsies. Our findings indicate that 3D Banff g-scores are more consistent across sections and, under the semi-automatic setting, the Volumetric strategy correlates more strongly with clinical biomarkers than traditional 2D scores. These results show that 3D volumetric quantification offers promising added value, underscoring the potential benefit of 3D-aware Banff scoring for kidney transplant pathology.
Attention U-Net improves nucleus segmentation in pathology images
Automated Nucleus Segmentation in Histology Images: An Attention U-Net Approach with Comprehensive Preprocessing and Inference Pipelines
Abstract: Objectives: In the area of digital pathology, nucleus segmentation is an essential step for quantitative analysis; however, high nuclear density and staining heterogeneity in histology images pose a great challenge. Methods: This study implements a lightweight Attention U-Net model on the MoNuSeg 2018 dataset to overcome these challenges. The proposed pipeline integrates comprehensive image and mask preprocessing, including stain deconvolution and multi-pass mask smoothing, with a high-fidelity overlapping patch-stitching strategy during inference on high-resolution images. Results: The model achieved an Intersection over Union (IoU) score of 0.8745 on full-resolution, unseen test images. This result demonstrates the effectiveness of attention mechanisms in enhancing feature localization and validates the stitching methodology for generating seamless and accurate segmentation maps. Conclusion: Attention U-Net is an effective and competitive method for automated, scalable nucleus delineation in challenging clinical contexts.
VGL-stGen connects lung tissue images with gene activity patterns
VGL-stGen: Learning a shared multimodal model for lung histology and spatial transcriptomics
Abstract: VGL-stGen is a multimodal large language model adapted from a pretrained medical vision-language model using paired lung H&E and spatial transcriptomics with single-cell references. Training integrates image-expression and expression-cell-type pairs, and gene-conditioned pseudo-labels transfer transcriptomic cell-type supervision to histology images. One deployed checkpoint supports thirteen evaluated tasks spanning tissue and cell-type classification, gene prediction and conditional expression completion from combinations of histology, cell identity and observed gene expression. Task-specific decoding produces categorical labels, gene lists and structured expression levels. For conditional completion, fixing queried gene identities and predicting their levels autoregressively improves structured prediction. Controlled adaptation shows that restricting supervision to requested expression-level tokens can further improve image-conditioned completion. Image-permutation experiments indicate that correctly paired histology adds information beyond observed expression. External classification relies partly on computational references with shared annotation lineage, and some H&E sources were exposed during cancer training or model development. Within these conditions, VGL-stGen demonstrates how a medical vision-language backbone can learn from spatial transcriptomics and histology to connect tissue morphology and molecular states through shared generative modeling.
Focus improves diagnosis of brain tissue during surgery
FOCUS: A Subspecialty Foundation Model for Intraoperative Central Nervous System Pathology
Abstract: Intraoperative frozen-section diagnosis of central nervous system (CNS) lesions guides surgical decisions but is challenged by artefacts, diagnostic complexity and time constraints. Most pathology foundation models have limited exposure to CNS frozen tissue. Here we present FOCUS, a subspecialty foundation model pretrained on 27,930 frozen-sections enriched for CNS tissue. FOCUS led 11 internal diagnostic and 12 biomarker-prediction tasks, with mean AUCs of 0.969 and 0.877, respectively, retaining leading performance in temporal and external cohorts. To provide more comprehensive diagnostic information, we further organized ten diagnostic tasks into a WHO-aligned diagnostic hierarchy and separately evaluated FOCUS for lymphoma detection, a critical task for intraoperative surgical decision-making. In reader assessments by six neuropathologists, FOCUS assistance enabled junior readers to approach or exceed unassisted senior readers in hierarchical diagnosis and raised junior readers' lymphoma sensitivity from 81.6% to 94.7%. FOCUS could improve diagnostic accuracy and granularity, inform lymphoma-related resection decisions and provide provisional molecular information. Such capabilities highlight the potential of FOCUS to provide robust, clinically actionable support for intraoperative CNS pathology.
AI tool improves speed and agreement in tumor cell counting
AI-assisted mitotic counting improves reproducibility and efficiency across multiple tumour types
Abstract: Mitotic counting is an important component of tumour grading, diagnosis and prognostic assessment across several tumour types, but manual assessment is time-consuming and subject to inter-pathologist variability. To help address these challenges, we developed MitPro, an AI tool designed to improve consistency and efficiency by directing pathologists towards regions with the highest predicted mitotic activity and highlighting mitotic figures for review, while retaining pathologist control over region selection and the final count. We evaluated its effect on the reproducibility and efficiency of mitotic counting in a retrospective, non-interventional, paired reader study comprising 385 whole-slide images from 3 centres in 3 countries and 7 tumour types using 3 different scanners. 13 pathologists participated, with each slide assessed independently by 3 pathologists without AI assistance and again with AI assistance after a minimum 2 week washout period. Across all slides, AI-assisted counting increased the intraclass correlation coefficient from 0.589 to 0.949. Mean pathologist-level median assessment time decreased from 286.4 to 127.8 seconds, corresponding to an average saving of 151.8 seconds per assessment. Improvements in agreement and efficiency were also observed in supporting analyses using HALO AP and Sectra image management systems and in 2 additional tumour types outside the main study population. AI-assisted assessment was associated with a subtle shift towards higher mitotic counts and scores, consistent with identification of more active mitotic hotspots and fewer missed mitotic figures. The frequency of score change between unassisted and AI-assisted assessment was comparable with inter-pathologist variation during routine counting. These findings support the use of MitPro as an assistive tool for more consistent and efficient mitotic assessment in routine practice.
Normal kidney images help detect rare glomerulus abnormalities accurately
Seeing Abnormal from Normal: Glomerular Abnormality in Representations of Normal Renal Morphology
Abstract: Fine-grained evaluation of glomerular pathology must distinguish normal glomeruli from abnormalities such as global and segmental glomerulosclerosis, obsolescent, ischemic, solidified, disappearing, and atubular glomeruli. Supervised classification requires labeled examples of every category, which is impractical when subtypes are rare or absent from the training cohort. One-class anomaly detection offers an alternative by modeling normal data and scoring deviations, allowing previously unseen abnormalities to be detected. We use the frozen residual U-Net backbone of Omni-Seg, pretrained to segment structurally normal renal primitives without abnormal-subtype labels. We propose NoRDeC (Normal-Reference Detection and Characterization), a framework combining Mahalanobis normal-reference scoring with layer-wise representation analysis to determine whether and where glomerular pathology is encoded, how spatial aggregation affects detection, and whether abnormalities alter inter-layer relationships differently. Using glomerular images from two institutions, we evaluate backbone layers and aggregation strategies, compare NoRDeC with PaDiM and PatchCore, and analyze representations using centered kernel alignment (CKA). Layer 4 with Center-70 aggregation achieved a pooled AUROC of $0.926\pm0.013$. NoRDeC achieved the highest AUROC in six of seven abnormality categories and in the pooled analysis, while CKA suggested subtype-dependent changes in inter-layer relationships not captured by anomaly scores alone. The normal-reference model is fitted using only normal glomeruli; abnormality labels are used for configuration selection, evaluation, and grouping in the representation analysis. These results show that a frozen renal feature extractor can support both detection and representation-level characterization of glomerular abnormalities without using abnormal examples to fit the detector.