Papers for

cardiovascular device designers

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

Diffusion method improves 3D coronary artery reconstruction from sparse images

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

Abstract: Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

Tue 3 NovComputer Vision and Pattern Recognition
The gist
Doctors often use pictures from different angles to see the 3D shape of arteries in the heart, but getting enough pictures can be hard and the images can be unclear. The authors created a new computer method that starts with a basic shape guess and then improves it using a special learned model that knows what heart vessels usually look like. Their method works well even with few pictures and lower image quality, producing more accurate 3D vessel shapes than other approaches tested. This could help doctors plan heart procedures better, though it still needs testing with real patient images.
Open → 2611.04604v1

Deep learning improves MRI resolution and noise in heart blood flow imaging

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

Abstract: Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

Mon 2 NovComputer Vision and Pattern Recognition
The gist
Heart blood flow is complicated and changes all the time, making it hard to measure clearly with MRI scans. The authors created a deep learning method called 4D-MRAR that can make these scans sharper and cleaner by increasing their spatial and temporal detail. Unlike earlier techniques, their method works well even when the heart moves a lot and changes shape. They trained it using simulated heart flow data and showed it also works well on real MRI scans, producing more accurate and reliable measurements of blood flow.
Open → 2611.04053v1

Synthetic datasets improve heart flow prediction with active learning

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

Abstract: Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

Mon 19 OctComputational Engineering, Finance, and Science
The gist
Predicting blood flow in different people’s hearts is tricky because everyone’s anatomy is unique. The authors built a large set of simulated heart shapes paired with blood flow data to train computer models that can quickly guess the blood flow in new hearts. They tested ways to improve these models by focusing on harder-to-predict cases and making predictions follow physical laws. Their work shows that carefully made training data and smart learning strategies can make these predictions better, especially when fine-tuning for new patients.
Open → 2610.27130v1