Papers for

building automation engineers

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

Multi-zone HVAC control lowers peaks using edge active inference agents

One Agent per Zone: Decentralised Active Inference under Partial Observability for Multi-Zone HVAC Control on Edge Hardware

Abstract: Multi-zone HVAC control is a shared-resource problem: zones on a floor share one fan and cooling coil, so each zone's demand affects its neighbours and the building's peak power. One controller per zone scales well and isolates faults, but each controller then observes only its own zone, not the shared air loop. In this work, we present a decentralised controller that assigns each zone an independent active-inference agent, which plans by minimising expected free energy and learns its zone dynamics online. The agents exchange no messages, so none depends on peers or a coordinator; each accounts for the unobserved coupling through a latent disturbance and a congestion signal derived from the metered power of the other floors. Fifteen agents are evaluated in EnergyPlus on a Sinergym office building against three rule-based controllers and three MADDPG fleets, one given the same floor meters. On five noisy weather years unseen during training, the fleet attains the lowest mean building peak (88.3 kW, 3 to 17 % below the baselines) and staggers the floor peaks better than any baseline, with a coincidence factor (building peak over the sum of the floor peaks) of 0.929 versus 0.936 to 0.994. Compared with a reactive rule at similar comfort (0.912 versus 0.916), it lowers the sum of monthly peaks, on which demand charges are billed, by 33 kW (4 %) in every year, at the cost of about 10 % more energy. It costs 9% less per year than the proactive rule (at lower comfort) and 1% less than the MADDPG fleet given the same floor meters, in every test year. The whole fleet runs on a single low-cost Raspberry Pi 5, closing the observation-to-action loop over MQTT in 442 ms at p95, far below the 15-minute control step.

Wed 14 OctMultiagent SystemsArtificial Intelligence
The gist
Controlling heating and cooling across multiple building zones is tricky because they share equipment, so what one zone wants affects the others. The authors created independent smart agents for each zone that learn and plan on their own, without talking to each other, to keep the building comfortable while using less peak power. These agents account for system-wide effects by watching overall power use instead of direct communication. Tested on a building simulation, this approach reduced peak power and demand charges better than existing rule-based and AI methods while running efficiently on a small, low-cost device.
Open → 2610.19790v1

Building AI models that optimize HVAC systems across many buildings

The Smart Buildings Challenge: Learning Foundation Models for Real-World Optimization at Scale

Abstract: Buildings cause nearly 40\% of carbon emissions in the US. Of total building emissions, HVAC systems are responsible for approximately 40-60\% and account for 15\% of global energy consumption. Despite advances in artificial intelligence, most buildings still operate as inefficiently as they did decades ago. Building optimization, perhaps more so than any other optimization problem, has enormous potential for Machine Learning (ML) driven impact on climate change, in both the short and long term. One of the biggest obstacles for building optimization is the lack of policy transfer. Most building control systems, whether simulation or learning based, don't generalize: they only work well for the building they were developed for, but not for other buildings. To solve this problem, we propose a challenge for the development of building foundation models that easily adapt to new buildings with minimal configuration and thereby enable building optimization to scale across the globe. Participants will build control policies on a set of simulated buildings, and have their policies evaluated on an unseen set of buildings. The buildings vary in size, layout, weather, material properties, and HVAC system. Successful outcomes from this initiative promise a massive leap forward in global sustainability efforts and demonstrate the great potential of ML to combat climate change.

Tue 13 OctArtificial Intelligence
The gist
Buildings use a lot of energy and create much pollution, mainly due to heating and cooling systems. Current computer programs that try to save energy only work well for one building at a time and don’t work well in others. The authors propose a challenge to build smarter AI models that can learn from some buildings and then help other buildings optimize their energy use without much extra setup. This could help many buildings save energy and reduce carbon emissions worldwide.
Open → 2610.18511v1

Smart buildings use edge computing for efficient data processing

Sustainable Cloud-Fog-Edge Systems for Smart Buildings: Algorithmic Adaptation under Memory Constraints and Dynamic Orchestration Strategies

Abstract: The escalating environmental footprint of the Information and Communication Technol- ogy (ICT) sectorwith global Data Center electric- ity usage potentially reaching 3% by 2030 and the imperative for real-time responsiveness in smart buildings demand a foundational shift towards Edge Computing. This article proposes a holis- tic architectural and algorithmic approach for cre- ating autonomous, resilient, and privacy-preserving learning systems within smart buildings, advancing the core concept of the building itself as the data center. Our contributions, demonstrating originality compared to conventional centralized systems, are structured around three main pillars: 1) Validation of resilient data acquisition chains using the af- fordable Arduino ecosystem (Uno R4 WiFi/BME280) and secure persistence solutions including centralized archiving (Node-RED/MySQL) and secure remote transfer (Python/rsync/SSH). 2). The proposal of a lightweight, KOptim orchestration framework, inter- operable with the FIWARE standard, for the dynamic management of Service Level Agreements (SLA). 3) The adaptation and experimental valida- tion of the Generalized Hebbian Algorithm (GHA) for Principal Component Analysis (PCA) on low- power microcontrollers,We introduce and compare an iterative learning strategy using data buffers, featuring sorting and explicit preservation of extreme samples to maintain diversity. Experimental results on the high-dimensional Tour Perret sensor data confirm that this novel method, despite introducing a necessary temporal complexity of O(W log W ) due to sorting, achieves convergence and final result quality that is visually equivalent to processing the entire dataset in full memory, reliably identifying two distinct operational states.

Fri 9 OctMachine LearningDistributed, Parallel, and Cluster Computing
The gist
Smart buildings need fast and energy-efficient ways to handle lots of data without relying on big remote servers. The authors show how using small, low-power devices inside buildings can collect and analyze data reliably and securely. They created a new method to teach these tiny devices to understand complex data despite their limited memory. Their tests show this method works well to spot different conditions in the building from sensor data, similar to traditional large-scale analysis.
Open → 2610.13307v1

AI readiness for buildings depends on data quality and control access

Which Buildings Are Artificial Intelligence-Ready? A Measurement-Based Assessment Framework for AI Question Answering and Actuation

Abstract: Agentic artificial intelligence (AI) systems are becoming the interface to buildings, answering questions and controlling operations, but a building's readiness for them has not been systematically assessed. This study proposes a framework to quantify it. First, a building's knowledge graph sets two ceilings. The answerable-readiness ceiling is the share of operational questions its data could answer, and the actuation-readiness ceiling is the share of control actions it exposes. Second, a reference AI agent's accuracy on a fixed set of these questions shows how much of the ceilings is realized. On a simulated office, the agent realizes 0.62 of a 0.64 answerable ceiling, so missing data, not the AI, limit readiness, except in naming a fault's cause. Across 37 public real-building graphs, the median answerable ceiling is 0.16, and in 15 of 45, unlinked sensors lower it. The framework turns "is this building AI-ready?" into an auditable, ranked retrofit question.

Tue 6 OctArtificial Intelligence
The gist
Buildings with AI systems can answer questions and control operations, but many are not fully ready for this. The authors created a way to measure how ready a building is for AI by checking how much of its data can answer questions and control functions. They tested this on a fake office and some real buildings, finding that missing or unlinked data often limit readiness. This measurement helps prioritize building upgrades for better AI use.
Open → 2610.09119v1

Time-series models need varied control data for smart system control

Time-series Foundation Models for Predictive Control: The Role of Excitation

Abstract: Deploying model predictive control (MPC) requires constructing or identifying a predictive model for each target system. Time-series foundation models (TSFMs) offer an attractive option thanks to strong zero-shot forecasting capabilities across systems. However, low forecast error does not guarantee that a TSFM captures the system's response to the alternative actions considered by the controller. We study this gap using residential heat-pump control as a test bed, measuring the agreement between predicted and ground-truth effects of control interventions. Importantly, we find that TSFMs can recover the system's input-response relationship when the context contains sufficient independent control excitation. Common fine-tuning pipelines and feature smoothing reduce, but do not eliminate, the need for in-context excitation. Our results indicate that current TSFMs used for predictive control require sufficiently informative control variation in the inference context. Initial closed-loop results show promise for shorter context windows.

Mon 5 OctMachine Learning
The gist
Controlling complex systems like home heating requires models that can predict how different actions will affect them. The authors studied advanced time-series models that forecast future behavior without extra training, but found good predictions alone don’t mean the model understands the system’s reactions to changes. They showed that these models only learn accurate responses when given enough varied examples of control actions within the data they see. This finding helps improve how these models can be used to make better decisions in real-time control tasks.
Open → 2610.06447v1

Battery-free wireless sensor sends encrypted indoor environment data

From WPT to Encrypted Telemetry: A Battery-Free Backscattering-based Polarimetric Wireless Sensor

Abstract: This work introduces an indoor Battery-Free Wireless Sensing Node powered through radiative Wireless Power Transfer (WPT). The proposed platform targets secure, energyefficient active sensing and overcomes key limitations of many prior battery-free approaches, which commonly provide neither on-node computation nor cryptographic protection. The node combines temperature, humidity, pressure and Volatile Organic Compound (VOC) measurements with a low-power microcontroller that executes sensor calibration, derives a VOC index, formats the payload, and applies AES-128 encryption before wireless transmission. Energy harvesting and communication are enabled by a 1-bit controlled Backscatter Rectenna (BR), which both scavenges incident RF power and produces an orthogonally polarized backscattered signal for robust polarimetric operation. Experimental results validate reliable multi-sensor readout and encrypted data transfer, while maintaining a very low energy budget for the complete sense-compute-encrypt-transmit cycle.

Thu 24 SeptNetworking and Internet Architecture
The gist
Many small wireless sensors can't run complex calculations or encrypt their data because they lack batteries. The authors present a sensor that works indoors without batteries by harvesting radio waves for power. This sensor measures temperature, humidity, air pressure, and chemicals in the air, then processes and encrypts that information before sending it wirelessly. Their device combines energy harvesting and communication in a simple antenna design, ensuring reliable and secure data transfer with very low energy use.
Open → 2609.29214v1

Generalized transfer learning improves building control without target data

Very Exciting: Zero-Shot Model Predictive Control of Buildings via Excitation-Based Generalized Transfer Learning Models

Abstract: The widespread adoption of data-driven, energy-efficient model predictive control (MPC) in buildings remains hindered by substantial effort to collect data and train models for individual buildings. Transfer learning (TL) has consequently gained increasing attention for target building modeling, as it reduces data requirements and modeling effort by reusing pretrained source models. However, these TL models are typically evaluated only on prediction accuracy in the target, without testing downstream control performance. To address this gap, we apply a state-of-the-art TL approach - pretraining a generalized model on multiple source buildings using standard operational data - within an MPC setup in a target building. We show that this approach is insufficient to achieve satisfactory control performance. As a solution, we introduce generalized models pretrained on excitation-based operational source data - purposefully probed inputs that explore the building's state-action space. For evaluation, we apply the generalized models via zero-shot (i.e., without fine-tuning) to 32 simulated target buildings and assess MPC performance. Our results show that excitation-based generalized models achieve the strongest control performance among all benchmarks, outperforming an online linear model-based MPC and a PI controller by 6.4% and 36.9%, respectively. By combining strong control performance with the ability to generalize across multiple buildings, without requiring any target-specific data, our approach reduces MPC setup cost and simplifies its widespread deployment in the building sector.

Fri 11 SeptMachine Learning
The gist
Managing energy in buildings is hard because each building needs its own detailed data and models. The authors tested using a single pre-trained model from many buildings to control a new building, but it didn’t work well for control tasks. They improved this by training models on special 'excitation' data that actively explores how the building responds to changes. This new approach lets buildings be controlled well without needing any data from the building itself.
Open → 2609.12853v1