Papers for
biometric system developers
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Embedding verification method controls false acceptance using identity ranking
Identities, Not Pairs: Distribution-Free False-Accept Control for Embedding-Based Verification
Abstract: Embedding-based verification often calibrates a false-accept threshold from all impostor pairs among $m$ identities, although these pairs share identities. We characterize a worst-case limit: when hub identities score highly against a fraction $ρ$ of the population, a calibration-only threshold with marginal false-accept rate (FAR) at most $α$ under every identity-exchangeable law reaches the hub score on hub-free calibration sets with probability at most $(m+2)α/(2ρ)$. Uniformly accepting near that score at levels well below $ρ/m$ therefore requires trial information. We propose COVE, which ranks the trial pair among all $N=\binom{m+2}{2}$ pairs formed by augmenting the calibration units with the probe and reference. Under identity exchangeability, its marginal FAR is at most $\lfloorαN\rfloor/N$, with first possible acceptance at $1/N=O(1/m^2)$. The rule also retains this guarantee with a fixed symmetric cohort-normalized score using an independent cohort. On 6 benchmarks and 8 frozen encoders, realised FAR was consistent with the exact bound. Where both valid calibration-only baselines accepted nothing, COVE retained a median $100\%$ of the sampled oracle's true-accept rate over reliable comparisons. In contrast, an empirical quantile over dependent pairs reached 2.87$\,α$ FAR, and a binomial upper confidence bound over pairs missed its nominal 95\% conditional-FAR target in up to 55\% of calibration draws. Symmetric CSLS raised COVE's true-accept rate by up to 4.3-fold in the tested settings. The code is available in https://github.com/salimkhazem/Cove.git
Biometric systems leak enough feedback to reconstruct user templates
How Much Feedback Is Needed to Break Template Protection? The Geometric Vulnerability of Biometric Authentication
Abstract: Biometric authentication systems increasingly use privacy-preserving mechanisms to protect sensitive templates. However, the authentication interface itself may still leak information that enables reconstruction attacks. Prior attacks exploit released similarity scores, whereas more advanced systems reveal only the binary accept/reject decision. This binary feedback provides substantially less information, making template reconstruction far more challenging. In this work, we introduce query-efficient reconstruction attacks under extremely limited feedback, addressing two key limitations of prior attacks. First, we introduce the first attack that reconstructs protected biometric templates using only authentication success/failure feedback by exploiting the geometric constraints of biometric authentication. Second, we introduce distribution-aware query-efficient reconstruction methods for score-releasing systems, achieving a more realistic threat model by reducing the number of required queries by a factor of $5\times$ compared to recent prior score-based attacks. Finally, we combine these two insights by incorporating a pretrained facial diffusion prior into our geometric binary attack, reducing the number of required queries by a factor of $5\times$. Our findings reveal a fundamental security limitation of biometric authentication: independently of the template protection mechanism, the authentication process itself exposes geometric information that can enable perfect template reconstruction up to numerical precision. Moreover, the distribution of biometric templates can be leveraged to make significantly more effective reconstruction attacks.
Infant fingerprint recognition improved by tuning quality assessment methods
Infant Fingerprints: Quality Assessment & Recognition
Abstract: Infant fingerprint recognition is hindered by a combination of physiological characteristics, such as small ridge width and spacing, and acquisition challenges that include involuntary motion, skin residue, and uneven fingertip pressure. These factors undermine fingerprint quality standards originally designed for adults, which assume feature distributions that do not hold for infants. To address this gap, this paper evaluates ten fingerprint quality assessment methods on a longitudinal dataset that spans six age groups from newborns to three months, alongside a parameter tuning routine that uncovers age-specific fingerprint characteristics to recalibrate methods with domain-dependent assumptions. Both default and tuned configurations are compared through recognition experiments assessing the effectiveness of quality-guided gallery selection. Template-fusion strategies and latent fingerprint recognition technologies are further examined to identify the best possible matching rates achievable by the top-performing method. Results show that tuned parameter sets outperform default configurations for the majority of methods and age groups, indicating that targeted recalibration of existing frameworks improves gallery utility and contributes to more reliable infant fingerprint recognition.
Fast and reliable fingerprint feature detection for modern workflows
Revisiting Handcrafted Minutiae Detection: A Simple and Effective Open Source Baseline for Modern Fingerprint Workflows
Abstract: Handcrafted minutiae detection algorithms remain fundamental to biometric science and forensic practice due to their full auditability, adherence to international standards, and operational independence from training datasets or GPU hardware. However, current open-source traditional baselines are severely outdated, relying almost exclusively on legacy C/C++ codebases that lack seamless integration with modern scientific software ecosystems. To bridge this gap, the present work introduces SBMEX (Skeleton-Based Minutiae EXtraction), a fast and deterministic minutiae detection method integrated into the open source \texttt{pyfing} package. SBMEX achieves high computational throughput by employing a dual Look-Up Table architecture that replaces runtime neighborhood scanning during Crossing Number computation and skeleton tracking. Additionally, it incorporates a continuous quality scoring framework driven by tracking path length, dual ridge-valley skeleton fusion, and spatial density decay. Rigorous evaluation on NIST SD302 datasets demonstrates that SBMEX delivers feature extraction accuracy comparable to or outperforming traditional open-source baselines without fine-tuning, while achieving a drastic reduction in minutiae detection latency relative to classical Crossing Number Python implementations.
Hybrid quantum classical models improve fingerprint recognition with contrastive learning
A Width-Matched Comparison of Hybrid Quantum-Classical Self-Supervised Learning for Fingerprint Recognition
Abstract: Fingerprint recognition is a widely deployed biometric, but supervised training requires large labeled enrollment sets. Self-supervised learning (SSL) removes this requirement, and hybrid quantum-classical models have been proposed to enrich the learned representations. Prior quantum SSL studies consider a single contrastive objective, so it is unclear whether reported benefits depend on the objective or can be attributed to the quantum circuit. We insert the QuFeX quantum feature-extraction module into three SSL frameworks, the contrastive SimCLR and MoCo v2 and the non-contrastive BYOL, and compare each hybrid with its classical counterpart at matched representation width (8 features, equal to 8 qubits) on the SOCOFing fingerprint dataset, with a CIFAR-10 control, using k-nearest-neighbor identification on encoder features. In single-run experiments the hybrid scores clearly higher for both contrastive objectives, whereas for BYOL a multi-seed analysis shows no reliable difference, suggesting that any benefit depends on the SSL objective. A hardware-efficient circuit (QNet) does not show the same gain. We examine whether the gains can be attributed to the quantum circuit, considering circuit architecture, trainable parameter count, nonlinearity, and the classical simulability of 8-qubit circuits.
Representative morphology heatmaps boost ECG biometric recognition accuracy
From ECG Signals to Representative-Morphology Heatmaps for Biometric Recognition
Abstract: Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-morphology heatmaps, a deterministic ECG-to-image representation adapted from ECGXtractor. Within each block of ten aligned beats, the five beats closest to the block mean are averaged into a 400 by L matrix and rendered either as a conventional trace or as a dense cardiac-time-by-lead heatmap. Since both representations contain identical physiological samples, their comparison isolates the effect of rendering. We evaluate verification and closed-set identification on PTB, ECG-ID, and MIMIC-IV-ECG-DEMO. Five compact models, including ZACH-ViT, are trained from scratch, while six ImageNet-pretrained CNN and transformer backbones assess model scale and visual transfer. Heatmaps improve both FNMR operating points and both identification ranks in all 15 compact model-dataset comparisons, while EER improves in 14. Across the matched experiments, EER decreases by 9.59 percentage points and Rank-1 increases by 24.69 points on average. ConvNeXt-Tiny reaches 2.43% EER on PTB and 5.79% on ECG-ID, whereas DeiT-Base reaches 14.92% on MIMIC-DEMO. ImageNet initialization clearly benefits the two multilead datasets but has a mixed effect on ECG-ID, and performance does not increase monotonically with model size. The best heatmap systems approach the strongest signal-domain EER on PTB and ECG-ID, while DeiT-Base provides the strongest evaluated performance on MIMIC-DEMO. Lead-channel ablation further shows that useful channel combinations depend on the cohort and biometric task. Overall, representative-morphology heatmaps provide an effective image representation for ECG verification and identification.