Papers for
biomedical engineers
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Framework enables shared muscle control across different body models
A generalist policy for muscle-driven control across individual musculoskeletal models
Abstract: Differences in musculoskeletal morphology challenge policy reuse across individual models. Here we present MyoAcross, a framework that combines individual musculoskeletal model construction, morphology-conditioned policy learning and virtual model augmentation to enable muscle-driven reference-motion tracking without individual fine-tuning. Across 31 held-out individual models, MyoAcross achieves 99.24% completion and reduces tracking error by 22.60% relative to an unconditioned multilayer perceptron. Policy reuse extends to models of 22 held-out individuals constructed from single-image shape estimates, measured height and body mass, and, with asymmetry augmentation, to models with unilateral lower-limb shortening. Comparisons with measurements from 120 additional individuals show agreement in vertical ground reaction force waveforms and channel-dependent agreement between simulated muscle activations and electromyography. These results establish a common control framework for comparative simulations of movement across individual musculoskeletal models.
EEG model controls reveal limits of pretrained and random features
Controlled Evaluation of EEG Foundation Models: Random Initialisation, Band-Power and Validation-Selected Probes
Abstract: EEG foundation models report downstream gains, yet their protocols seldom include three controls. These are the same encoder untrained, spectral features fitted on the same data, and a layer picked without looking at test scores. We therefore evaluate five publicly released EEG foundation models and an in-house JEPA-style model under one protocol with all three controls and several seeds, on five benchmarks and four added task families. The controls change the reading in three ways. First, picking the probed layer by its test score raises the layer-wise peak by an average of +0.034 and reverses the peak-versus-output gap in 9 of 36 cells. Second, with the layer picked on validation, random initialisation matches or beats pretraining for half of the models on sleep and emotion, and no model beats a five-band log-power baseline on emotion or motor imagery. Third, after full fine-tuning only 5 of 30 pairs gain beyond twice their seed spread, and the one clear loss of -0.290 AUROC persists under matched learning rates. From these results we draw four reporting practices, and we release every cell for re-analysis.
EEG foundation models vary in how they use brain signal details
Probing Spatial and Spectral Grounding in EEG Foundation Models
Abstract: EEG foundation models are advancing at an unprecedented pace, yet their evaluation is driven by downstream accuracy, which reveals little about whether their predictions rely on physiologically interpretable signal structure. We introduce a set of perturbation probes in two grounding axes: spatial grounding in channel identity and topographic locality, and spectral grounding in oscillatory content and waveform morphology. We apply these probes to five published EEG foundation models across motor-imagery and seizure recordings. Our experiments reveal differences in both representational sensitivity and downstream reliance. Electrode identity may be encoded without influencing downstream classification: permuting LaBraM's positional codes heavily displaced its embeddings yet reduced motor-imagery accuracy by only 1.2 points, while spectral details may be discriminable without producing specific responses to simulated clinical markers, as only REVE exceeded a spectral baseline on this task. These dissociations are hidden in common benchmarks, demonstrating how grounding probes can complement performance-based evaluation by revealing what EEG foundation models encode and what their predictions depend on.
Dna components surveyed for building molecular communication networks
Surveying Experimentally-Validated Components for DNA-Based Molecular Communication
Abstract: Molecular communication is a novel paradigm for the design of nanonetworks. It uses molecules as information carriers and enables communication between nanodevices. DNA-based molecular communication is a promising approach for medical applications, such as in-body networks for diagnostics and drug delivery. However, the transition from theoretical models to practical experiments is still in its early stages. This survey reviews experimentally validated DNA-tiles, nanocarriers, and biosensors relevant to implementing DNA-tile-based nanonetworks in vitro. We evaluate these components based on their stability, compatibility, cost-effectiveness, and overall suitability for wet-lab implementation. Based on this analysis, we identify promising component combinations and derive a blueprint for a minimal proof-of-concept experiment. The resulting framework provides researchers with both a structured overview of experimentally relevant design choices and a concrete starting point for implementing and validating DNA-based nanonetworks in the wet lab.
AI helps find tumor growth patterns despite messy sparse data
AI-Assisted Tumor-Growth Law Discovery from Sparse Data: Refitting and LLM-Based Ranking
Abstract: Inferring tumor-growth laws from sparse, noisy observations requires more than accurate curve fitting. We study an AI-assisted workflow involving symbolic regression, mathematical admissibility checks, coefficient refitting, and large language model (LLM) ranking. Synthetic Gompertz data allow trajectory fit, forecasting, and recovery of the governing growth law to be assessed separately. A dense noiseless control recovers the generating family, but sparse noisy sampling frequently leads to alternative forms. Among retained candidates in the tested configurations, physics-informed neural network refitting often increases growth-law error, whereas classical nonlinear least squares usually reduces it. A separate exploratory analysis of archived LLM rankings shows no consistent improvement over selection by training error and identifies errors in mathematical reasoning. Plausible saturation, accurate trajectory fits, and convincing explanations can therefore coexist with incorrect growth laws. Mathematical validity and law recovery require evaluation alongside predictive performance.
Modeling molecular signals in pulsating blood flow for healthcare
Analytical Modeling of Open- and Closed-Loop Dispersive Molecular Communication Channels with Pulsatile Flow
Abstract: Molecular communication (MC) is a communication paradigm in which information is conveyed through the release, propagation, and reception of molecules. Many envisioned healthcare applications of MC are expected to operate inside the human body, where the cardiovascular system (CVS) may serve as the physical propagation environment and molecular transport is governed by diffusion and blood flow. Although blood flow is inherently pulsatile, most analytical MC channel models assume steady flow. In this paper, we develop a time-variant analytical model for dispersive MC channels with pulsatile flow. We derive the straight-duct response as a Normal distribution with time-variant mean and variance, capturing the combined effects of diffusion and pulsatile flow, and extend it to closed-loop channels through a wrapped-Normal representation. The model is validated against three-dimensional (3D) particle-based simulations (PBSs) for synthetic and physiologically motivated velocity waveforms. We further derive a closed-form first-order approximation for the first-arrival peak time and introduce the nondimensional indicator $S_{\mathrm{Rx}}$ for assessing the applicability of the reduced one-dimensional (1D) model. Our results show that pulsatility has the strongest influence when molecular transport is predominantly advective and the temporal flow variations are not averaged out, whereas stronger diffusion and faster pulsations reduce its impact on the received signal. Moreover, a PBS-based parameter sweep supports $S_{\mathrm{Rx}} \ge 2$ as a practical criterion for the applicability of the proposed analytical model. Finally, relating the analytical assumptions to representative blood-vessel classes shows that model applicability depends not only on the transport conditions but also on physiological properties such as vessel rigidity, geometric uniformity, and blood rheology.
Complex networks share a general limit on peak activity levels
A General Capacity Frontier of Complex Networks
Abstract: From cells to cities, ecosystems to economies, complex networks exhibit peak intensities that define their empirical limit. Estimating these limits traditionally requires domain-specific knowledge. We demonstrate that a wide range of complex networks share a capacity frontier that constrains these maxima. We formalize this regularity by proposing Structural Capacity Theory for Network Substrate Structured Systems. These systems couple a fixed network substrate with an observable dynamical process. The frontier is learned from a vector representation of the network substrate and modulated log-additively by a vector representation of the dynamical process. Frontiers trained on one set of domains reliably bound empirical maxima of entirely different ones without observing their peak intensities or simulating their dynamics. Independent learning paradigms converge on consistent upper bounds. Frontier performance is stable under perturbation, yet degrades under deliberate falsification, with no performance gain under ablation. These findings support the capacity frontier as a generalizable constraint that describes how network structure bounds dynamical processes across otherwise unrelated systems.
Foundation models show mixed transfer success on muscle signal tasks
EMG-FM-Bench: A Comprehensive Benchmark for Foundation Model Transfer and Adaptation on Electromyography
Abstract: Foundation models (FMs) are increasingly being developed for general time series and physiological signals, yet their transferability to downstream physiological tasks remains poorly understood. This question is particularly challenging for electromyography (EMG), where signal distributions vary substantially across users, sensing configurations, acquisition hardware, and downstream tasks. We introduce EMG-FM-Bench, a systematic benchmark for studying foundation-model transfer and adaptation on EMG. EMG-FM-Bench unifies 20 public datasets with over 1 million EMG segments and evaluates nine pretrained foundation models across four questions: how pretrained models perform when frozen or fully fine-tuned, how much pretraining helps compared with training the same model from scratch, how well models generalize to new users with limited labeled data, and how performance changes across different EMG tasks. Across the benchmark, linear probing provides useful information about pretrained representations, but full fine-tuning can substantially change downstream EMG performance. Comparing each pretrained model with the same model trained from scratch shows that the benefit of pretraining varies substantially across models and is not universal. Performance decreases when models are evaluated on new users, while five-shot adaptation improves macro-F1 in 70.2% of evaluated model-dataset combinations but recovers only part of the lost performance. Model performance is highly consistent between upper- and lower-limb classification and remains strongly correlated with continuous EMG-to-text decoding. Together, these results provide a systematic view of when pretrained time-series models transfer effectively to EMG and how their performance depends on fine-tuning, user variation, and downstream task.
SimAuthor improves scientific simulator creation with persistent revision
SimAuthor: Harnessing Foundation Models for Persistent Scientific Simulator Authoring
Abstract: Foundation models can generate scientific code, but authoring a scientific simulator (an executable program encoding hypotheses about how mechanisms generate observable signals) requires iterative refinement. Scientific adequacy rarely admits a unique implementation or exact test, so simulators must instead be judged against limited real observations. We study this setting as scientific simulator authoring under weak empirical feedback, where distributional comparisons between simulated and real signals guide revision, and the target is the simulator itself rather than only its generated samples. We introduce SimAuthor, a persistent authoring harness that retains and revises executable simulators, separates scalar search scores from structured discrepancy feedback, and accumulates reusable implementation mechanisms. We evaluate SimAuthor on six biomedical tasks spanning cardiac and respiratory audio, photoplethysmography (PPG), and electrocardiography (ECG). Under a fixed 100-attempt budget, SimAuthor outperforms PUCT score search on all six tasks, generally outperforms textual-strategy optimization, and achieves the highest endpoint score on five of six. The authored simulators also improve on unseen recordings, transfer to independent pretrained representations, and yield substantial out-of-distribution gains in downstream ECG classification. Finally, 111 of 138 audited revisions alter program structure and account for 86.1% of the signed score improvement. These results suggest that persistent revision can progressively convert foundation-model knowledge into better executable scientific simulators from limited empirical evidence.
Dna labeling capacity fully characterized for single-label cases
On the Capacity of DNA Labeling in the Single-Label Setting
Abstract: DNA labeling has attracted increasing attention in biomedical applications, including molecular imaging, diagnostics, and genomic analysis. In a DNA labeling process, a set of DNA sequence patterns, referred to as labels, is designed according to the requirements of a specific application. For each DNA sequence, the labeling process generates an output sequence that records the positions of the labels. DNA sequences with different labeling outputs can therefore be distinguished through the labeling process. To quantify this capability, the labeling capacity is defined as the exponential growth rate of the maximum number of DNA sequences that can be distinguished through the labeling process as the sequence length tends to infinity [2]. To date, the labeling capacities of several cases in the single-label setting have been determined. In this paper, we formulate the labeling process as a deterministic channel and show that its zero-error capacity is equal to the labeling capacity. For a single label, the corresponding channel can be represented by a star graph. Thus, characterizing the labeling capacity of a single label is equivalent to determining the zero-error capacity of the corresponding star graph. We derive the zero-error capacities of all star graphs, thereby providing a complete characterization of the labeling capacities for all single-label cases. Furthermore, we develop a general method for constructing capacity-achieving codes. These results apply to labeling problems over arbitrary finite alphabets and are not restricted to the DNA alphabet. Finally, for a fixed label length, we exactly characterize the range of achievable labeling capacities and identify all single-label structures that attain the minimum and maximum capacities.
Emgforge simulates muscle electrical signals from MRI images
emgforge: an automated end-to-end pipeline for simulating surface EMG on MRI-based volume conductors
Abstract: Simulated electromyograms are used to understand what an electrode records, to test decomposition and estimation algorithms on signals with known ground truth, and to train learning-based decoders. Most simulators fix the geometry to a cylinder or a slab, or stop at the lead field and leave the rest to the user. We present emgforge, an open pipeline that takes a labelled MRI segmentation of a limb to surface EMG in one command: a tetrahedral mesh with conductivity tensors aligned with each muscle's fibres; one reciprocal finite-element solve per electrode, valid for every fibre of every muscle; fibre beds that are straight or follow the muscle's shape; a motor-unit pool obeying the size principle; motor-unit action potentials on any electrode layout; and a motoneuron-pool and twitch layer that turns a drive or a movement into interference EMG and force. We describe the pipeline stage by stage, and at each stage we show, with an example, why the choice was made. The step that turns a lead field into a single-fibre action potential -- direct line-source synthesis -- is checked against a closed-form solution ($r = 1.0000$, zero lag), and the whole chain against fifty checks with numeric criteria from the physiological literature. We then use the pipeline for four studies: what an electrode sees as a function of depth, fat, spacing and montage; whether fibre geometry changes the signal; how much crosstalk a grid over one muscle receives from its neighbours; and how interference EMG scales with drive. The code, the validation suite and three datasets with ground truth are released.
Neural system separates contaminants to score muscle signal quality
Prism-SQA: An Interpretable and Adaptable Neural Framework for Surface Electromyography Quality Assessment
Abstract: sEMG is vulnerable to various contaminants that distort signal morphology and spectral content. Accurate signal quality assessment (SQA) is essential for identifying such degradation and ensuring reliable clinical analyses and decisions. Recent neural network-based SQA methods achieve accurate quality estimation by learning complex contamination patterns, yet their black-box nature prevents clinicians from understanding or validating the reported scores and limits adaptability to application-specific quality definitions without retraining. To address these limitations, we propose Prism-SQA, an interpretable and adaptable neural framework that reformulates SQA as a physiology-aware source-separation and verification process. Prism-SQA decomposes each input signal into a clean sEMG component and five contaminant-specific components using a U-Net with bidirectional long short-term memory. Each separated contaminant component is examined by a Contaminant Fingerprint Verifier, which enforces physiological plausibility by comparing its temporal and spectral structure with canonical contaminant signatures. This design allows clinicians to inspect how each contaminant affects signal quality, grounding the assessment in transparent, signal-level evidence rather than opaque latent representations. Quality indices computed from the verified components further enable customization of quality criteria across clinical contexts without retraining. We evaluate Prism-SQA on continuous quality-score estimation using synthesized noisy sEMG from public Ninapro datasets and on binary quality classification using a clinical dysphagia dataset. Results show that Prism-SQA achieves competitive or better performance than contemporary black-box neural methods while providing explicit interpretability and adaptability, advancing toward practical and clinically aligned sEMG SQA.