Papers for

biomedical device makers

Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.

Feature-axis attention improves medical image model transfer reliability

Learning Features, Not Layouts: Feature-Axis Attention as a Transfer Prior for Medical Imaging

Abstract: Natural-image-pretrained foundation models are increasingly adapted to medical imaging, yet transfer remains unreliable under domain shift, modality heterogeneity, and label scarcity. We trace part of this fragility to an overlooked design choice. Standard vision transformers place all global modeling on self-attention over spatial tokens, an object-layout prior well suited to natural scenes but not to medical images, where the discriminative signal lies in feature correlations and texture that recur across scanners while layout does not. We ask whether the axis of global attention, spatial versus feature, is itself a lever for transferable medical representations. Existing channel-aware hybrids confound this question, adding channel attention to a spatially-mixed backbone and leaving the axes coupled and the feature axis unmeasurable in isolation. We design FAD-ViT, a backbone that strictly decouples the two axes, making feature-axis attention the primary global operator and the attention axis a controlled variable. Evaluating comprehensively across 23 classification, segmentation, and low-data tasks under matched tokenization, capacity, and protocol, we find that shifting global attention from the spatial to the feature axis leaves from-scratch performance essentially unchanged, yet markedly strengthens transfer. Identical ImageNet pretraining yields up to roughly three times the transfer gain, with consistent improvements on every held-out segmentation task at up to a quarter the parameter count and far lower compute than standard and channel-attention baselines. The advantage is largest where texture rather than geometry is discriminative, tracking greater reuse of pretrained features. The axis of global attention is thus a design lever for medical transfer, and making it channel-primary is a simple, cheap, and principled choice.

Fri 9 OctComputer Vision and Pattern Recognition
The gist
Medical imaging models often struggle to work well when used on different machines, types of scans, or when there is little data. The authors found that most models focus on understanding images by looking at spatial layouts, which suits everyday photos but not medical images where consistent texture patterns matter more than layout. They designed a new model that pays more attention to features (like texture) rather than where things are in the image. This new design transfers better to different medical imaging tasks, needing fewer resources and fewer model parameters.
Open → 2610.13012v1

Compression keeps stem cell image models accurate on standard CPUs

Retention-Constrained Post-Training Quantization of Cellpose-SAM for Stem Cell Microscopy

Abstract: Induced pluripotent stem cell (iPSC) culture increasingly relies on segmentation foundation models, yet deployment on laboratory CPUs and edge hardware requires compression schemes that are both efficient and auditable. We present a deployment-oriented evaluation of compressed Cellpose-SAM using a pre-specified retention criterion: the 95% cluster-bootstrap interval of mean change from FP32 must remain above a fixed -0.02 margin for every imaging modality. On a stratified 176-field panel spanning BBBC038 nuclei, BBBC039 U2OS fluorescence, and NIST iPSC images across density regimes, weight-only W8A16 preserves instance F1 across all modalities. A sensitivity-guided mixed W4/W8 scheme, using four INT8 exceptions, achieves a 6.76x reduction in weight storage with no observed catastrophic failures (0/176 fields), matching W8A16 at this sample size. In contrast, ternary weight-only quantization achieves 12.08x compression but fails catastrophically on 169/176 fields. These results demonstrate that compression should be evaluated by modality-stratified downstream retention rather than single-number accuracy, and establish a reproducible protocol for auditing compressed foundation models in regulated stem-cell imaging.

Thu 17 SeptEmerging Technologies
The gist
Stem cell research uses computer models to identify cells in microscope images, but these models can be too large for common lab computers. The authors tested ways to shrink a popular model called Cellpose-SAM without losing accuracy. They found that some compression methods keep the model nearly as good as the full version while using much less storage. Extremely simple compression made the model unreliable, showing that careful testing is needed for each image type to keep results trustworthy.
Open → 2609.21038v1