Side vent design reduces microphone sensor sensitivity to contact changes

Side-Vent Design for Microphone-Based Mechanomyography Sensors: Modeling and Experimental Evaluation of Contact Dependence

Abstract: Wearable muscle sensing for rehabilitation, assistive robotics, and electrical-stimulation feedback needs mechanomyography sensors less sensitive to fit changes during wear. In microphone-based mechanomyography, cavity pressure depends on rim contact, a dependence housing design has rarely targeted. This study evaluates a side-vented housing, whose vent opens a pressure-relief path in parallel with the rim to lower contact dependence, and quantifies the acoustic-gain cost. Thermoviscous finite-element simulations compared twenty cavity configurations under prescribed source motion. Paired bench sweeps over 10-200 Hz on both housings compared direct contact with a Gap-ring spacer, a radially grooved spacer ring. At 100 Hz, side venting reduced the simulated acoustic-gain variation across 0.10-0.50 mm rim clearances from 25.8 to 10.0 dB and cost 5.5 dB of gain at 0.20 mm clearance. Velocity fields and branch-flow calculations identified this path. At the higher speaker drive level, the Gap-ring spacer caused median attenuations of 13.6 dB (vented) and 30.1 dB (unvented) relative to direct contact. In this front end, a 35.9-dB signal-gain increase at 100 Hz raised the calculated operational-amplifier voltage-noise gain by 1.6 dB. A single-participant demonstration of paced elbow flexion and extension compared envelope timing and spectra between housings, finding similar envelope timing (correlation 0.935) and broadly similar spectra (correlation 0.956). Vent area trades acoustic gain against contact dependence and can therefore serve as a housing design parameter.

Sun 11 OctHuman-Computer Interaction
The gist
Muscle sensors worn on the body are used in rehab and robotics but often suffer from changing how well they fit, which affects their readings. The authors studied how adding a side vent to the sensor housing changes the sound pressure inside, making the sensor less sensitive to how tightly it touches the skin. This vent lowers the variation caused by different skin contacts but slightly reduces the sensor's overall signal strength. Tests showed the vent design still captured muscle signals well during simple arm movements, suggesting it could improve wearable muscle sensors.
Open → 2610.15600v1

MyoFlow improves muscle signal gesture recognition across users and sessions

MyoFlow: Anchor-Tied Rectified Flow for HD-sEMG Gesture Recognition Across Sessions and Subjects

Abstract: High-density surface electromyography (HD-sEMG) gesture recognition supports prosthetic control, assistive robotics, and rehabilitation, but electrode re-donning and physiological variability cause distribution shifts that degrade accuracy across sessions and subjects. Generative HD-sEMG models primarily synthesize signals for augmentation; although diffusion models enhance representation learning, prediction still relies on a separate classifier. To tie learned dynamics to the decision rule, we propose MyoFlow, the first discriminative flow-matching framework for HD-sEMG recognition across sessions and subjects. It recasts classification as anchor-tied transport: a domain-conditioned rectified flow moves encoded windows toward gesture anchors that serve as transport targets and define the nearest-anchor decision geometry, enabling zero-shot prediction without an independent head. On the Hyser dataset, MyoFlow improves mean cross-session and cross-subject accuracy over the strongest diffusion-based baseline by 4.24\% and 6.37\%, respectively, and achieves 91.71\% mean zero-shot accuracy and 97.39\% mean few-shot accuracy across multiple days on the CEMHSEY dataset.

Tue 15 SeptMachine Learning
The gist
Recognizing hand gestures from muscle signals can be tricky because the signals change when people wear sensors differently or over time. The authors developed MyoFlow, a method that more accurately identifies gestures from these muscle signals even when conditions vary. It works by moving signal representations closer to known gesture patterns, allowing it to predict gestures without extra steps. Tests showed it outperforms previous methods, achieving high accuracy across different days and users.
Open → 2609.17194v1