Papers for
assistive robotics engineers
Papers whose findings have a practical use for this group, as judged from the abstract. Open a paper to read what it means in practice.
Side vent design reduces microphone sensor sensitivity to contact changes
Side-Vent Design for Microphone-Based Mechanomyography Sensors: Modeling and Experimental Evaluation of Contact Dependence
Abstract: Wearable muscle sensing for rehabilitation, assistive robotics, and electrical-stimulation feedback needs mechanomyography sensors less sensitive to fit changes during wear. In microphone-based mechanomyography, cavity pressure depends on rim contact, a dependence housing design has rarely targeted. This study evaluates a side-vented housing, whose vent opens a pressure-relief path in parallel with the rim to lower contact dependence, and quantifies the acoustic-gain cost. Thermoviscous finite-element simulations compared twenty cavity configurations under prescribed source motion. Paired bench sweeps over 10-200 Hz on both housings compared direct contact with a Gap-ring spacer, a radially grooved spacer ring. At 100 Hz, side venting reduced the simulated acoustic-gain variation across 0.10-0.50 mm rim clearances from 25.8 to 10.0 dB and cost 5.5 dB of gain at 0.20 mm clearance. Velocity fields and branch-flow calculations identified this path. At the higher speaker drive level, the Gap-ring spacer caused median attenuations of 13.6 dB (vented) and 30.1 dB (unvented) relative to direct contact. In this front end, a 35.9-dB signal-gain increase at 100 Hz raised the calculated operational-amplifier voltage-noise gain by 1.6 dB. A single-participant demonstration of paced elbow flexion and extension compared envelope timing and spectra between housings, finding similar envelope timing (correlation 0.935) and broadly similar spectra (correlation 0.956). Vent area trades acoustic gain against contact dependence and can therefore serve as a housing design parameter.
MyoFlow improves muscle signal gesture recognition across users and sessions
MyoFlow: Anchor-Tied Rectified Flow for HD-sEMG Gesture Recognition Across Sessions and Subjects
Abstract: High-density surface electromyography (HD-sEMG) gesture recognition supports prosthetic control, assistive robotics, and rehabilitation, but electrode re-donning and physiological variability cause distribution shifts that degrade accuracy across sessions and subjects. Generative HD-sEMG models primarily synthesize signals for augmentation; although diffusion models enhance representation learning, prediction still relies on a separate classifier. To tie learned dynamics to the decision rule, we propose MyoFlow, the first discriminative flow-matching framework for HD-sEMG recognition across sessions and subjects. It recasts classification as anchor-tied transport: a domain-conditioned rectified flow moves encoded windows toward gesture anchors that serve as transport targets and define the nearest-anchor decision geometry, enabling zero-shot prediction without an independent head. On the Hyser dataset, MyoFlow improves mean cross-session and cross-subject accuracy over the strongest diffusion-based baseline by 4.24\% and 6.37\%, respectively, and achieves 91.71\% mean zero-shot accuracy and 97.39\% mean few-shot accuracy across multiple days on the CEMHSEY dataset.